Supply Ability | 10000 Kit/Kit per Day |
Delivery Time | To be negotiated |
Packaging Details | Kit |
Product name | 2019-NCoV Neutralizing Antibody Rapid Test (Immunochromatography) |
Composition | Detection card, sample buffer |
Storage conditions | 2℃~30℃ |
term of validity | twelve months |
Sample requirements | Serum, plasma or whole blood |
Brand Name | ZOSBIO |
Model Number | 2019-NCoV Neutralizing Antibody |
Certification | CE BfArm |
Place of Origin | Henan,China |
View Detail Information
Explore similar products
BetaCoronavirus Sars-Cov-2 Neutralization Antibody Test Immunochromatography
ZOSBIO Coronavirus Neutralizing Antibody Rapid Test 1Test/Kit To 100Tests/Kit
ZOSBIO 2019-Ncov Neutralization Antibody Test Kit
SARS-CoV-2 Coronavirus Neutralizing Antibody Rapid Test
Product Specification
Supply Ability | 10000 Kit/Kit per Day | Delivery Time | To be negotiated |
Packaging Details | Kit | Product name | 2019-NCoV Neutralizing Antibody Rapid Test (Immunochromatography) |
Composition | Detection card, sample buffer | Storage conditions | 2℃~30℃ |
term of validity | twelve months | Sample requirements | Serum, plasma or whole blood |
Brand Name | ZOSBIO | Model Number | 2019-NCoV Neutralizing Antibody |
Certification | CE BfArm | Place of Origin | Henan,China |
High Light | Coronavirus Neutralizing Antibody Rapid Test 2C ,Coronavirus Neutralizing Antibody Rapid Test 30C ,Biosensor covid neutralizing antibody test |
The biosensor is used to detect neutralizing antibodies of New Coronavirus (2019 ncov) in human serum, plasma and whole blood samples.
COVID-19 (2019-ncov) β It belongs to New Coronavirus in vivo. It can cause viral pneumonia. Clinical symptoms include fever, fatigue, dry cough, etc. some patients have nasal congestion, runny nose, sore throat, diarrhea and other symptoms. Severe cases of dyspnea and / or hypoxemia usually occur within a week. Severe cases will develop rapidly due to acute dyspnea syndrome, septic shock, maladaptive metabolic acidosis and hemorrhagic dysfunction.
New Coronavirus has many structural proteins such as s, E, m and n. Spindles include receptor binding domains (RBDS) that recognize the cell surface. Receptor angiotensin converting enzyme 2 (ACE 2). We found that RBD of 2019 ncov tattoo protein has a strong interaction with human ACE2 receptor, which can induce virus replication in host cells and lungs.
New Coronavirus infection or vaccination can trigger an immune response and produce antibodies in the blood. After infection, they will stay in the human circulatory system for months to years. In order to prevent virus replication, they will quickly and closely combine with pathogens. This antibody is called neutralizing antibody. Neutralizing antibody test can determine whether people have the ability to prevent infection.
The kit consists of a test card and a sample buffer.
Test card: composed of aluminum foil bag, desiccant, test strip and plastic card. The strip consists of absorbent, nitrocellulose membrane, sample pad, inner liner and rubber plate. The T-line (detection line) of nitrocellulose membrane was coated with ACE2 protein, the c-line (quality management line) was coated with antibody of quality management line, and the R-line (contrast line) was coated with antibody of large group. The combination pad was coated with 2019 ncov antigen.
Sample buffer: phosphate, sodium azide, etc
1. Collect serum, plasma or whole blood samples.
2. Precipitates and floats in the sample affect the experimental results and must be removed by centrifugation.
3. Anticoagulants: Jellyfish skin, EDTA, sodium citrate The use of anticoagulants has little effect.
4. Blood sampling should be done by a medical professional. Serum / plasma testing is the first choice. In case of emergency or special circumstances, the patient's whole blood sample can be used for rapid examination.
5. The storage time of serum and plasma samples should not exceed 8 hours at room temperature. It can be stored in 2 ° C ~ 8 ° C 6 months, 5 days or less, ~ 20 ° C, but repeated freeze-thaw cycles should be avoided. Freezing time of whole blood sample should not be less than 48 hours ℃ -8 ℃.
Please read the guide carefully before the exam. Please lower all tested drugs to room temperature before testing. The test shall be conducted at room temperature.
1. Remove the test card from the packaged test bag and use it within 1 hour.
2. 20 μ Add l sample (serum, plasma or whole blood) into the filling hole of the test card, and then drop 2 drops (about 60 drops) μ l) Add sample buffer and start timing.
3. The reaction time was 10-15 minutes at room temperature. The result was invalid after 20 minutes.
Result judgment chart of test card:
1. Invalid results: the quality management line (C line) has no response line, the test is invalid, and the experiment needs to be carried out again.
2. Negative results: the detection line (t line) appeared red band, and its color rendering was higher than that of control line (r line), quality management line (C line) and control line (r line).
3. Positive results: the test line (t line) had no red band, or the test line (t line) had red band, but the color development was lower than that of the control line (r line), and the quality was decreased. Control line (C line) and control line (r line).
This element is only used for in vitro diagnosis.
2. In order to test, it is necessary to add an appropriate amount of sample. Too many or too few samples will lead to incorrect results.
3. Hemolysis, blood lipid, jaundice and contaminated samples may affect the test results and should be avoided.
4. Reagent test results are only for clinical reference, can not be used as the only basis for clinical diagnosis and treatment. The final diagnosis of the disease must be based on a comprehensive evaluation of all clinical and laboratory results.
1. Specificity analysis
1.1 cross reaction: the following types of antibody evaluation were conducted for interference with reagents, and no cross reaction occurred.
SN | Item | Cross reaction | SN | Item | Cross reaction |
1 | Endemic human coronavirus OC43 | No | 10 | Enterovirus | No |
2 | Endemic human coronavirus HKUI | No | 11 | EB virus | No |
3 | Endemic human coronavirus NL63 | No | 12 | Measles virus | No |
4 | Endemic human coronavirus 229E | No | 13 | Human cytomegalovirus | No |
5 | Influenza A virus | No | 14 | Rotavirus | No |
6 | Influenza B virus | No | 15 | Norovirus | No |
7 | Respiratory syncytial virus | No | 16 | Mumps virus | No |
8 | Adenovirus | No | 17 | Varicella-zoster virus | No |
9 | Rhinovirus | No | 18 | Mycoplasma pneumoniae | No |
1.2 interfering substances: in New Coronavirus (2019 ncov) neutralizing antibody test items, the potential interference of the following substances is assessed by adding the following substances in a specific concentration sample. The results show that all kinds of interfering substances will not interfere with the detection results of reagents.
Interfering substances | Concentration | Interfering substances | Concentration |
Bilirubin | ≤50mg/dL | Triglycerides | ≤15mmol/mL |
Hemoglobin | ≤5g/L | Cholesterol L | ≤500mg/d |
Rheumatoid factor | ≤500IU/mL | Human total IgG | ≤14mg/mL |
Ribavirin | 0.4mg/mL | Fluticasone | 0.5mg/mL |
Oxymetazoline | 10mg/mL | Dexamethasone | 5 mg/mL |
Histamine hydrochloride | 10mg/mL | Triamcinolone acetonide | 5mg /mL |
Tobramycin | 1mg/mL | Levofloxacin | 0.2 mg/mL |
Oseltamivir | 1mg/mL | Azithromycin | 0.1 mg/mL |
Zanamivir | 1mg/mL | Ceftriaxone | 0.4 mg/mL |
Arbidol | 0.5mg/mL | Meropenem | 0.2 mg/mL |
2.Clinical study: 120% positive and 300 negative samples were selected from Novell coronavirus (2019 nCoV) IgG test reagents (colloidal gold method) as controls. The results are summarized below.
2019-nCoV IgG Ab detection reagent (colloidal goldmethod) |
Sum | |||
Positive | Negative | |||
| Positive | 115 | 5 | 120 |
Negtive | 5 | 295 | 300 | |
Sum | 120 | 300 | 420 | |
Sensitivity | 95.83%, (95%CI: 90.62%~98.21%) | |||
Specificity | 98.33%, (95%CI: 96.16%~99.29%) |
1. This product is used only for in vitro diagnosis.
This product cannot be used after it is thrown away.
3. Before you start, read the operating guide carefully and follow the reagent guide to perform the experiment.
4. Do not conduct experiments in harsh environments such as disinfectants, sodium hypochlorite, acid-base, acetaldehyde, other corrosive gases, and dusty environments. After the experiment, it must be disinfected in the laboratory.
5. All samples and reagents used are considered potentially contagious substances and should be destroyed according to local regulations.
6. Reagents must be used within the shelf life marked on the outer package. Use the induction card as soon as possible to remove it from the aluminum foil bag and prevent moisture.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2016
Employee Number:
500~1000
Ecer Certification:
Active Member
Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi... Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi...