Payment Terms | T/T |
Supply Ability | 100 Units Per Month |
Delivery Time | 8 working days |
Packaging Details | Carton Box |
Dimensions | 3U , 480 - 404 - 130mm |
IP protection level | Protection IP20 |
Nested Loop | Support 3 Layers |
Software Protection | Upper Voltage limit |
Voltage and Current Testing Sample | 4 - wire connecting |
Discharge lowest Voltage | 1.5V |
Brand Name | Neware |
Model Number | CT-4008T-5V6A-S1 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
10Hz DQdV DCIR Button Coin Cell Battery Tester
3U2F 8 Channel Pouch Battery Cell Tester IP20 With Offline Testing Function
CCD CPD CRD Discharge 8 Channel Lithium Battery Analyzer
Max Current 6000mA Battery Tester Machine , High C Rate Battery Testing Device
Product Specification
Payment Terms | T/T | Supply Ability | 100 Units Per Month |
Delivery Time | 8 working days | Packaging Details | Carton Box |
Dimensions | 3U , 480 - 404 - 130mm | IP protection level | Protection IP20 |
Nested Loop | Support 3 Layers | Software Protection | Upper Voltage limit |
Voltage and Current Testing Sample | 4 - wire connecting | Discharge lowest Voltage | 1.5V |
Brand Name | Neware | Model Number | CT-4008T-5V6A-S1 |
Certification | CE | Place of Origin | China |
High Light | 8 channel Battery Cell Tester ,Neware Battery Cell Tester ,Echelon Utilization 8 channel battery analyzer |
Neware 8 Channer Cell Tester Lithium Battery Echelon Utilization Capacity Tester
a . New technology and upgraded producing process make this idea come into reality . Of course , high C - Rate charge - Quick charge is another reason for higher current testers become more popular than before . For a 3000mAh cell battery , people want to charge it at 6000mA - 2C or even 9000mA - 3C current .
b . And in some labs , researchers are trying 10C or even higher C - Rate charge or discharge . In this situation , 5V12A is the very rising star for both battery manufactures and researchers .
c . The accuracy for current and voltage on these channels is 0.05 percent of FS . From the base system that provides the highest level of accuracy and time resolution , features can be added to allow the 5V6A test system to perform virtualy many type of test , with many type of products – cylindrical , pouch and coin cells , super – capacitors , etc , and chemistries .
d . To meet the various requirements adopted in advanced battery research , our equipments can automatically switch the current range in accordance with user settings to maintain consistent accuracy , and can be fitted with additional hardware to provide a number of optional features and capabilities .
e . Cylindrical batteries need to be clamped between the upper and down clamps of the equipment . By moving the position of the upper accessory accurately according to the scales on both sides , you can test different capacities of Cylinders Batteries .
Input Power | 425W | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | 1.5V - 5V |
Discharge Min Voltage | 1.5V | |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Current | Per Channel Current Range | Range1 , 5mA - 1A Range2 , 1A - 6A Range3 , 6A - 12A |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA | ||
Record Frequency | 10Hz | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time | ||
IP protection level | Protection level IP20 | |
A Means of Communication of Upper Machine | TCP / IP Protocol | |
Data Output | EXCEL , TXT , Graph | |
Communication Interface | Ethernet Port |
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
250000000-350000000.00
Employee Number:
350~500
Ecer Certification:
Active Member
Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ... Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ...
Get in touch with us