Payment Terms | T/T |
Supply Ability | 100 Units Per Month |
Delivery Time | 8 working days |
Packaging Details | Carton box , 530 - 360 - 130mm |
Per Channel Voltage Range | -5V - 5V |
Per Channel Current Range | Range1 , 5uA – 1mA Range2 , 1mA – 10mA Range3 , 10mA – 20mA |
Accuracy | 0.05 percent |
Current Response Time | 1ms above |
Resolution | AD - 24bit , DA - 24bit |
Min Pulse Width | 500ms |
Brand Name | Neware |
Model Number | CT-4008Tn-5V20mA-164 |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Cutting Edge Lithium Ion Battery Analyzer Material GSM PULSE DCIR Tester
1000HZ Lithium Battery Testing Equipment , Neware Battery Testing Device
0.1uA To 5A 1000Hz Lithium Ion Battery Analyzer system Four Range
25W High Rate Discharge Cell Tester , Neware Rechargeable Battery Tester
Product Specification
Payment Terms | T/T | Supply Ability | 100 Units Per Month |
Delivery Time | 8 working days | Packaging Details | Carton box , 530 - 360 - 130mm |
Per Channel Voltage Range | -5V - 5V | Per Channel Current Range | Range1 , 5uA – 1mA Range2 , 1mA – 10mA Range3 , 10mA – 20mA |
Accuracy | 0.05 percent | Current Response Time | 1ms above |
Resolution | AD - 24bit , DA - 24bit | Min Pulse Width | 500ms |
Brand Name | Neware | Model Number | CT-4008Tn-5V20mA-164 |
Certification | CE | Place of Origin | China |
High Light | CE Neware Battery Charge Discharge Tester ,5V 10mA Battery Charge Discharge Tester ,CE Neware Lithium Ion Battery Analyzer |
Neware BTS4000 Series Lithium Ion Battery Charge Discharge Testing Analyzer
This 8 Channels Coin Cell Analyzer 5V10mA provides most applications in battery testing fields such as electrode materials research, battery performance test , small - scale battery formation , capability grading , battery pack testing and etc .
20 set of mA Neware battery testers can be put in one rack
dQ / dV differential capacity curve , the peak on the curve indicates that there is a voltage plateau on the charge and discharge curve , and different peaks represent different electrochemical reactions .
Testing with the uA current unit is more accurate and more convenient .
CT-4000 Multi Range mA Battery Testing System , characterized with 0.05 percent of FS accuracy and down to uA capability , enables users to perform DCIR tests , dQ / dV and other basic tests on three - electrode system .
It mainly focuses on battery research and development instituions and universities .
The design of the uA current unit plays a vital role in the field of current accurate measurement , which is more convenient and more accurate . Generally , magnetoelectric galvanometer can achieve uA level , electromagnetic galvanometer can achieve mA level . Sensitive galvanometer is used for students to check weak current or tiny voltage in DC circuit in the lab . It is a kind of high sensitive magnetoelectric instrument , which can measure the tiny curren.
Input Resistance | More than 1MΩ | |
Input Power | 25W | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | 0V - 5V |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Current | Per Channel Current Range | Range1 , 5uA – 1mA Range2 , 1mA – 10mA Range3 , 10mA – 20mA |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Power | Per Channel Output Power | 0.25W |
Stop current | Range 1 , 2uA Range 2 , 0.02mA Range 3 , 0.04mA | |
Stability | 0.1percent of FS | |
Time | Current Response Time | 1ms |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Min Current - Range 1 , 2uA Range 2 , 0.02mA Range 3 , 0.04mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers |
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
250000000-350000000.00
Employee Number:
350~500
Ecer Certification:
Active Member
Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ... Neware is a leading battery testing system provider headquartered in Shenzhen, China. Neware has been committed to providing high performance battery testing system since 1998. Neware Battery Charge and Discharge Test System, ranging from μA single cell applications up to 1MW packs, is a ...
Get in touch with us
Leave a Message, we will call you back quickly!