Place of Origin | China |
Brand Name | Benray Medical |
View Detail Information
Explore similar products
Medical ventilator
ICU Ventilator
ICU Ventilator
CPAP System
Product Specification
Place of Origin | China | Brand Name | Benray Medical |
BR-MV15A ICU Ventilator
ADULT · PEDIATRIC
Application
The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Indra-operation, post-operation respiratory support, other respiratory treatment.
Features
l 15” TFT LCD touch screen displays the ventilation parameters, alarm information and waveforms.
l Air compressor runs stably with low noise, creates quiet environment for doctors and patients.
l Integration breathing circuit design.
l Multiple working modes such as volume control and pressure limit.
l Multiple parameters monitoring interface to show clear parameter to the operator, allow operator know the patient conditions in all aspects.
l Real time pressure-time, flow-time loop graphics, pressure volume loop graphics and high precision ETCO2, O2 concentration detection function included.
l Electrical PEEP control
l Breathing valve is disassembly and can be disinfected.
Safety
l Three levels alarm system, visual and sound alarm information.
l With multiple type of alarms, reminding and protection functions.
l Self-check before running, eliminate system mulfuction.
l Advanced power management control technology.
l With built-in backup power supply, when normal power supply shut down, back-up power supply will start work automatically.
l Separate design of electric and gas, keep safety running of ventilator.
Specifications
Ventilation modes: | IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV |
Ventilator parameter ranges |
|
Tidal volume(Vt) | 0 ~ 2000mL |
Frequency (Freq) Oxygen concentration | 1bpm ~ 100 bpm 21%-100% |
I/E | 4:1~1:8 |
PEEP | 0cmH2O ~ 40 cmH2O |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitored Parameters |
|
Frequency (Freq) | 0 /min ~ 100 /min |
Tidal volume(Vt) | 0 mL ~ 2500 mL |
MV Airway pressure Dynamic lung compliance testing ETCO2 Concentration | 0 L/min ~ 99 L/min 0 cmH2O ~ 100 cmH2O 1mL/cmH2O ~ 1000mL/cmH2O 0mmHg ~ 152mmHg (0%-20%) |
Oxygen concentration | 15 % ~ 100 %
|
Oscillographs display: |
|
P-T(pressure – time) |
|
F-T(flow – time) |
|
P-V loop (pressure – volume loop) |
|
V-T(volume – time ) |
|
ETCO2-T (End-tidal CO2 - time) |
|
|
|
Alarms and protection |
|
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | ≤11.3±0.3V |
No tidal volume | No tidal volume within 6s |
High Minute Volume alarm Low Minute Volume alarm | 5L/min-99L/min 1L/min-30L/min |
High Airway pressure alarm Low Airway pressure alarm High oxygen concentration alarm Low oxygen concentration alarm | 20cmH2O-100cmH2O 0cmH2O-20cmH2O 19%-100% 18%-99% |
Continuous pressure alarm | (PEEP+1.5cmH2O) over 16s |
Suffocation warning Fan error Oxygen deficit | 5-60s Show on screen Show on screen |
The maximum limited pressure | <12.5 kPa |
|
|
Working conditions |
|
Gas source | O2, AIR |
Pressure | 280kPa-600kPa |
Voltage | ~220V±22V |
Power frequency | 50Hz ± 1Hz |
Input power | 900VA (with air compressor) 250VA (without air compressor) |
Ventilation modes: | IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV |
Ventilator parameter ranges |
|
Tidal volume(Vt) | 0 ~ 2000mL |
Frequence (Freq) Oxygen concentration | 1bpm ~ 100 bpm 21%-100% |
I/E | 4:1~1:8 |
PEEP | 0cmH2O ~ 40 cmH2O |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitored Parameters |
|
Frequence (Freq) | 0 /min ~ 100 /min |
Tidal volume(Vt) | 0 mL ~ 2500 mL |
MV Airway pressure Dynamic lung compliance testing ETCO2 Concentration | 0 L/min ~ 99 L/min 0 cmH2O ~ 100 cmH2O 1mL/cmH2O ~ 1000mL/cmH2O 0mmHg ~ 152mmHg (0%-20%) |
Oxygen concentration | 15 % ~ 100 %
|
Graphical display: |
|
P-T(pressure – time) |
|
F-T(flow – time) |
|
P-V loop (pressure – volume loop) |
|
V-T(volume – time ) |
|
ETCO2-T (End-tidal CO2 - time) |
|
|
|
Alarm and protection |
|
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | ≤11.3±0.3V |
No tidal volume | No tidal volume within 6s |
High Minute Volume alarm Low Minute Volume alarm | 5L/min-99L/min 1L/min-30L/min |
High Airway pressure alarm Low Airway pressure alarm High oxygen concentration alarm Low oxygen concentration alarm | 20cmH2O-100cmH2O 0cmH2O-20cmH2O 19%-100% 18%-99% |
Continuous pressure alarm | (PEEP+1.5cmH2O) over 16s |
Suffocation warning Fan error Oxygen deficit | 5-60s Show on screen Show on screen |
The maximum limited pressure | <12.5 kPa |
|
|
Working conditions |
|
Gas source | O2,AIR |
Pressure | 280kPa-600kPa |
Voltage | ~220V ±22V |
Power frequency | 50Hz ± 1Hz |
Input power | 900VA (with air compressor) 250VA (without air compreesor) |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller,Other
Year Established:
2005
Total Annual:
5,000,000-10,000,000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou Benray Medical Equipment Co., Ltd. was established in 2005,which is a collection of development, production, sales and service as one of the major medical equipment manufacturing enterprises. The company has been uphold the creation of value for customers, for the community to create wealt... Guangzhou Benray Medical Equipment Co., Ltd. was established in 2005,which is a collection of development, production, sales and service as one of the major medical equipment manufacturing enterprises. The company has been uphold the creation of value for customers, for the community to create wealt...
Get in touch with us
Leave a Message, we will call you back quickly!