Payment Terms | T/T |
Delivery Time | 15 DAYS |
Packaging Details | 100*80*25mm |
Type | ECG007 |
Name | ECG/RESP/TEMP Module |
Package | standard |
ECG Full lead | I,II,III ,aVL, aVR, aVF, and V1,V2,V3,V4,V5,V6 |
Warranty | 1 year |
Weight | 60g |
Work current | <100mA |
Power supply voltage | DC from 3.6 V to 6.0 V |
Working temperature | Scope: 20-50℃ |
size | 100*80*25mm |
Gain | 5mm/mV,10mm/mV,20mm/mV and 40mm/mV |
Scanning speed: | Changeable with three grades 12.5mm/s,25mm/s and 50mm/s |
elivery time Mass production | about 15 days (2000pieces) |
OEM | about 25 days |
RESP RATE RANGE | 3-150bpm |
Brand Name | BERRY |
Model Number | ECG007 |
Place of Origin | Shanghai |
View Detail Information
Explore similar products
Ecg / Resp / Temp Oximeter Patient Monitor Parts Module
DC 3.6 V To 6.0V Patient Monitor Module CCU And Anesthesia Operation Appliance
SPO2 Oximeter Monitor OEM Module Board 50x40x10mm
OEM Patient Monitor Module Small Volume SPO2
Product Specification
Payment Terms | T/T | Delivery Time | 15 DAYS |
Packaging Details | 100*80*25mm | Type | ECG007 |
Name | ECG/RESP/TEMP Module | Package | standard |
ECG Full lead | I,II,III ,aVL, aVR, aVF, and V1,V2,V3,V4,V5,V6 | Warranty | 1 year |
Weight | 60g | Work current | <100mA |
Power supply voltage | DC from 3.6 V to 6.0 V | Working temperature | Scope: 20-50℃ |
size | 100*80*25mm | Gain | 5mm/mV,10mm/mV,20mm/mV and 40mm/mV |
Scanning speed: | Changeable with three grades 12.5mm/s,25mm/s and 50mm/s | elivery time Mass production | about 15 days (2000pieces) |
OEM | about 25 days | RESP RATE RANGE | 3-150bpm |
Brand Name | BERRY | Model Number | ECG007 |
Place of Origin | Shanghai | ||
High Light | DC 3.6V spo2 module ,NDIR ECG module ,DC 6.0V spo2 module |
ECG007oem module spo2 oem module ECG module
Technical Specifications:
1. Principle of Operation: Non-dispersive infrared (NDIR)
2. Initialization Time: Capnogram displayed in less than 20 seconds Reaching full specifications
within 2 minutes.
3. Co2 Measure Range: 0 - 150 mmHg; 0 - 19.7%; 0 - 20kPa
Co2 Measure Resolution: 0.1mmHg
Co2 Accuracy: 0-10mmHg ± 2mmHg; 41-70mmHg ± 5% of reading;
71-100mmHg ± 8% of reading; 101-150mmHg ± 10% of reading
4. Calibration: No routine user calibration required, The mainstream sensor an airway adapter
5. Zero is required when changing to a different airway adapter
6. Compensation: Barometer Pressure 450 - 850 mmHg.
7. Operator selectable O2, N2O, He compensation.
8. Data Interface: Rs232, 19200 baud rate, standard N-8-1.
9. Regulatory: Designed to comply YY0601 and ISO21647
The YS3000 is a stand-alone external pulse oximetry module that can be externally connected to a multiparameter monitor,or a hand-held oximeter and other devices that require measurement of oxygen saturation. Connecting to your device via a simple TLL interface, the module can measure blood oxygen saturation accurately with a SpO2 sensor.
► Small volume,flexible installment mode,high reliable and accurate test. |
► Excellent reliability and clinical monitoring fuction. |
► It has implemented the monitor of 7 channel ECG, 1channel RESP and2channels temp on the same time. |
► In accordance with function safety design of CE requirements. |
► In accordance with all the ecg/temp monitoring work |
► Suitable for adult,pediatric and neonate. |
► Single power 5V work,low power consumption design. |
Feature
1. Small volume,flexible installment mode,high reliable and accurate test.
2. Excellent reliability and clinical monitoring fuction.
3. It has implemented the monitor of 7 channel ECG, 1channel RESP and2channels temp on the same time.
4. In accordance with function safety design of CE requirements.
5. In accordance with all the ecg/temp monitoring work,
6. Suitable for adult,pediatric and neonate.
7. Single power 5V work,low power consumption design.
Specification
ECG:
Full lead: I, II, III, aVL, aVR, aVF and V
Gain 5mm/mV, 10mm/mV, 20mm/mV and 40mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 1 times/minute to 300 times/minutes
Accuracy: ±1 time/minute
Variation of heart beat LORENZE drawing:Analysis on heart beat data for the
current 5 minutes with histogram during RR period.
Resp
Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method 0 time/minute – 100 minutes/minute
Precision of chest impedance method 1 time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute
(including baby)
Detection precision of respiration rate: ±1 time/minute
Temp
Single/double path
Type: Vascular/surface temperature
Scope:20℃~50℃
Accuracy±0.2℃
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
2003
Total Annual:
5000000-20000000
Employee Number:
80~100
Ecer Certification:
Verified Supplier
Brief Introduction of company Shanghai Berry Electronic Technology Co., Ltd is located in the beautiful,low carbon and environmental protection city Shanghai Caohejing Hi-Tech Park. We are devoted to researching and developing,manufacturing and sales of medical electronic i... Brief Introduction of company Shanghai Berry Electronic Technology Co., Ltd is located in the beautiful,low carbon and environmental protection city Shanghai Caohejing Hi-Tech Park. We are devoted to researching and developing,manufacturing and sales of medical electronic i...
Get in touch with us
Leave a Message, we will call you back quickly!