Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 100000 Box/carton |
Delivery Time | 2-7 days |
Packaging Details | carton/box |
Delivery | Within 48 hours |
Packaging Specifications | 8 x 12 strips, 96 wells |
Country Of Origin | China,BeiJing |
Detection Limit | 18 months |
Storage | 2-8℃ |
Specimen | Whole blood |
Assification | class1 |
Product Type | Elisa Test Kit |
Product name | CA12-5 Elisa Test Kit |
Package | Carton/Box |
Brand Name | BIOVANTION |
Model Number | TY0031 |
Certification | ISO 13485 |
Place of Origin | CHINA |
View Detail Information
Explore similar products
BIOVANTION Anti Thyroglobulin Antibody Test Anti Tg Ab Test Kit
Anti-TPO ELISA TEST KIT(Anti-Thyroid Peroxidase)
HAV IgG Elisa Kit Antibody Diagnostic Kit For Hepatitis A Virus
HEV Human Igg Elisa Kit Diagnostic For IgG Antibody To Hepatitis E Virus
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 100000 Box/carton |
Delivery Time | 2-7 days | Packaging Details | carton/box |
Delivery | Within 48 hours | Packaging Specifications | 8 x 12 strips, 96 wells |
Country Of Origin | China,BeiJing | Detection Limit | 18 months |
Storage | 2-8℃ | Specimen | Whole blood |
Assification | class1 | Product Type | Elisa Test Kit |
Product name | CA12-5 Elisa Test Kit | Package | Carton/Box |
Brand Name | BIOVANTION | Model Number | TY0031 |
Certification | ISO 13485 | Place of Origin | CHINA |
High Light | IgE antibody ELISA Test Kit ,Laboratory ELISA Test Kit ,ELISA Test Kit for Laboratory |
INTENDED USE
This kit is a quantitative detection of total IgE antibody (IgE) in human serum/plasma in vitro. This result can assist type Ⅰ allergy diagnosis. Moreover, total IgE testing may also be recommended for patients with suspected parasitic diseases.
Product details | Description |
Delivery | Within 48 hours |
Packaging Specifications | 8 x 12 strips, 96 wells |
Country Of Origin | China |
Manufacturer | 18 months |
Preservation method | 2℃-8℃ |
Specimen | Whole blood |
Assification | class1 |
Type | Elisa Test Kit |
PRINCIPLE OF THE TEST
Immediate hypersensitivity (typeⅠ allergies) is mediated by specific IgE. IgE concentration in normal serum peaks between 6 and 15 years of age. In most cases, the increase of specific IgE in patients is accompanied by the increase of total IgE titer. In this case, the titer can go up to 1,000 times. In general, international units per milliliter (IU/mL) are defined as: 1 IU/mL equals 2.4ng IgE. In patients with hereditary allergic dermatitis, IgE levels can be as high as 50,000 IU/mL. In addition, IgE titers are elevated in patients with parasitic diseases. Higher-than-normal test results should also take into account the impact of confirmed autoimmune diseases.
The reagent is not recommended for healthy people physical examination, testing results of positive or negative only on behalf of the corresponding IgE antibody test results positive or negative, uncertainty correlation with patient is sick and may not be as the only index of evaluation of patients, must be combined with patient clinical presentation and other laboratory tests for integrated analysis of the illness.
The detection method of this kit is enzyme-linked immunoassay. In this reagent, the principle of double antibody sandwich immunoassay was adopted. Monoclonal antibodies that recognize anti-IgE were pre-coated in the wells of the microplate, and human serum/plasma samples and enzyme-labeled another monoclonal antibody were added into the pores of the plate. After incubation and washing, substrate solution was added.
OD value was read and its content was calculated by a microplate reader.
INTERPRETATION OF RESULTS
Chromometry: Read the sample's optical density (OD) at 450nm/630mm with a microplate reader.
The detection range is 5~1000IU/mL. When serum/plasma samples with Total IgE antibody concentration over 1000IU/mL, accurate results can be obtained only if the sample are diluted with normal saline and tested again. The final result of the diluted sample is the test result multiplied by the dilution factor.
If the test results are out of the normal range, indicating abnormalities, the final diagnosis should be determined in combination with clinical symptoms and other indicators.
Company Details
Business Type:
Manufacturer,Importer,Exporter,Trading Company,Seller
Ecer Certification:
Verified Supplier
Biovantion Inc is independent from international department of Bioneovan Co., Ltd., which established in 2 0 0 5, is an in vitro diagnostic reagents manufacturer engaged in the research, development, production, and focus on clinical testing for infectious diseases, such as Hepatitis virus, Noro vir... Biovantion Inc is independent from international department of Bioneovan Co., Ltd., which established in 2 0 0 5, is an in vitro diagnostic reagents manufacturer engaged in the research, development, production, and focus on clinical testing for infectious diseases, such as Hepatitis virus, Noro vir...
Get in touch with us
Leave a Message, we will call you back quickly!