Payment Terms | T/T(Negotiable) |
Supply Ability | 300 units per year |
Delivery Time | 30-60days |
Packaging Details | Wooden cases |
Name | Pleated Cartridge Air Filter |
Material | Carbon Steel |
Efficiency | 99% |
Filtration Area | 672㎡ |
Air Flow | 21000CMH |
Media | 100% Polyester |
Application | Power Plant,Lithium Battery Plant |
Brand Name | AUZOER |
Model Number | CDC-32-4 |
Place of Origin | CHINA |
Certification | ISO |
View Detail Information
Explore similar products
Electric Industrial Dust Collector Machine for Lithium Battery Production
Low Pressure Industrial Dust Removal System / Industrial Baghouse Dust
Oil Mist Dedusting Industrial Dust Removal System Sintered Plate Dust Collection
Pleated Filter Cartridge Dust Collector Synthetic Fiber Medium Material
Product Specification
Payment Terms | T/T(Negotiable) | Supply Ability | 300 units per year |
Delivery Time | 30-60days | Packaging Details | Wooden cases |
Name | Pleated Cartridge Air Filter | Material | Carbon Steel |
Efficiency | 99% | Filtration Area | 672㎡ |
Air Flow | 21000CMH | Media | 100% Polyester |
Application | Power Plant,Lithium Battery Plant | Brand Name | AUZOER |
Model Number | CDC-32-4 | Place of Origin | CHINA |
Certification | ISO | ||
High Light | room dust collector ,industrial dust control systems |
Explosion Proof Sawdust Removal System With Cartridge Dust Collector 3020X2150X3520
CDC Downward Flow Cartridge Dust Collectors
Model | Dimension(mm) | Modular (pcs) | Filter Area(㎡) | Pulse Valves | Filter Cartridge QTY(pcs) | G.W.(KG) | ||||
Length | Width | Height | Polyester | Paper | Size | QTY(pcs) | ||||
CDC1-1 | 1670 | 635 | 1366 | 1 | 9.4 | 23 | 3/4" | 1 | 1 | 473 |
CDC2-2 | 1670 | 635 | 1860 | 1 | 18.8 | 46 | 2 | 2 | 633 | |
CDC3-3 | 1670 | 635 | 2315 | 1 | 28.2 | 69 | 3 | 3 | 748 | |
CDC8-2 | 1014 | 2150 | 2520 | 1 | 75 | 168 | 1" | 4 | 8 | 925 |
CDC12-3 | 1014 | 2150 | 3520 | 1 | 112 | 252 | 6 | 12 | 1216 | |
CDC16-4 | 1014 | 2150 | 3970 | 1 | 150 | 336 | 8 | 16 | 1280 | |
CDC18-3 | 1514 | 2150 | 3520 | 1 | 170 | 378 | 9 | 16 | 1510 | |
CDC24-3 | 2018 | 2150 | 3520 | 2 | 225 | 504 | 12 | 24 | 1865 | |
CDC32-4 | 2018 | 2150 | 3970 | 2 | 300 | 672 | 16 | 32 | 2235 | |
CDC36-3 | 3020 | 2150 | 3520 | 3 | 338 | 756 | 18 | 36 | 2615 | |
CDC48-4 | 3020 | 2150 | 3970 | 3 | 451 | 1008 | 24 | 48 | 3185 | |
CDC48-3 | 4023 | 2150 | 3520 | 4 | 451 | 1008 | 24 | 48 | 3450 | |
CDC64-4 | 4023 | 2150 | 3970 | 4 | 601 | 1344 | 32 | 64 | 4070 | |
CDC60-3 | 5026 | 2150 | 3520 | 5 | 564 | 1260 | 30 | 60 | 4430 | |
CDC72-3 | 6030 | 2150 | 3520 | 6 | 676 | 1512 | 36 | 72 | 4830 | |
CDC80-4 | 5026 | 2150 | 3970 | 5 | 752 | 1680 | 40 | 80 | 5085 | |
CDC96-4 | 6030 | 2150 | 3970 | 6 | 902 | 2016 | 48 | 96 | 6070 | |
CDC112-4 | 7040 | 2150 | 3970 | 7 | 1052 | 2352 | 56 | 112 | 7040 | |
CDC128-4 | 8050 | 2150 | 3970 | 8 | 1203 | 2688 | 64 | 128 | 8000 |
Tips
Use the Right Parts
Make sure your dust collector system is using the right parts, from the blower, dust filter, a filter-cleaning system, dust receptacle or dust removal system, to cartridges and baghouse solenoids, fans and valves. Each part plays a role to ensure the collector is operating at design point. We recommend using factory recommended replacement parts and be leery of less expensive alternatives.
Is Your Hopper Free of Dust?
A duct collector’s hopper should never be used to store dust. The hopper is intended to funnel process dust to a storage bin. Dust accumulating in a hopper creates a potential fire or deflagration risk. Dust in your hopper will also clog the system and diminish the collector’s performance and prevent the pulse-cleaning from doing its job.
Check Diaphragm Valves
It’s smart to make checking your diaphragm valves a priority each year. Particularly when new baghouses or cartridges are installed, it is recommended to check the valves and ensure that all filters are cleaned properly from the beginning. Remember that it’s always cheaper to replace diaphragm valves that it is to buy new filters because of inadequate pulsing. (Remember to wear appropriate ear protection when testing pulse valves as the noise level can rise considerably.)
Regularly Check Your Ductwork
The National Fire Protection Association requires protection for the ductwork and safety processes upstream of the dust collector. It’s smart to equip your ducting with a flow-activated isolation valve protecting downstream work areas from the propagation of flame and pressure through the inlet duct when deflagration occurs in a dust collector. If there is deflagration in a dust collector, the pressure will close the valve preventing the passage of flame and smoke to areas upstream from the valve. The valve latches shut and must be reopened manually. Some parts of the valve may be damaged, and a thorough inspection is required before the valve is back in service.
Company Details
Business Type:
Manufacturer
Year Established:
2014
Total Annual:
300-500
Employee Number:
>100
Ecer Certification:
Active Member
Auzoer is established as one of the manufacturers in the Air Pollution Control industry for more than 15 years. Our experience covers all facets of Dust, Mist, Fume and Industrial Ventilation Control systems for general industrial applications. We have cartridge dust collector,baghouse dust colle... Auzoer is established as one of the manufacturers in the Air Pollution Control industry for more than 15 years. Our experience covers all facets of Dust, Mist, Fume and Industrial Ventilation Control systems for general industrial applications. We have cartridge dust collector,baghouse dust colle...
Get in touch with us
Leave a Message, we will call you back quickly!