Temperature control range | :-50℃~110℃ |
Temperature measurement error: | ±0.5℃ |
Sensor model: | ntc(10K/3435) |
Control precision: | DC12V/DC24V/AC110V~230V(can be choose) |
Working current: | MAX200Ma |
Relay contact current: | AC5A/220V |
Working temperature: | 0℃~50℃ |
Meter length: | 90mm(L)*60mm(W)*26.5mm(H) |
Hole size: | 70mm(L)*50mm(H)l |
Packaging Details | Packing: standard expert carton |
Port | NINGBO |
Supply Ability | 10000 Piece/Pieces per Month |
Place of Origin | Zhejiang, China |
Model Number | STX-ST3012 |
View Detail Information
Explore similar products
Beautiful outline intelligible dual temperature controller
OEM Industrial temperature controller
Input signal K,J,PT100 Analog temperature controller SG-742
Light Weight Temperature Controller Kampa CX-72VM High Quality
Product Specification
Temperature control range | :-50℃~110℃ | Temperature measurement error: | ±0.5℃ |
Sensor model: | ntc(10K/3435) | Control precision: | DC12V/DC24V/AC110V~230V(can be choose) |
Working current: | MAX200Ma | Relay contact current: | AC5A/220V |
Working temperature: | 0℃~50℃ | Meter length: | 90mm(L)*60mm(W)*26.5mm(H) |
Hole size: | 70mm(L)*50mm(H)l | Packaging Details | Packing: standard expert carton |
Port | NINGBO | Supply Ability | 10000 Piece/Pieces per Month |
Place of Origin | Zhejiang, China | Model Number | STX-ST3012 |
AC 220V 12V 24V Dual Probe Digital LED Dual Thermometer Temperature Controller Thermostat Incubator Control Microcomputer
This is a dual display and dual control temperature controller,it can both control refrigeration or heating of two products, setting method is same of left and right.
*Technical parameters.
Temperature control range:-50℃~110℃
Temperature measurement error:±0.5℃
Sensor model:ntc(10K/3435)
Control precision:DC12V/DC24V/AC110V~230V(can be choose)
Working current:MAX200Ma
Relay contact current:AC5A/220V
Date preserve:available.
Working temperature:0℃~50℃
Storage temperature:-10℃~60℃
Meter length:90mm(L)*60mm(W)*26.5mm(H)
Hole size:70mm(L)*50mm(H)l
Distribution probe length is 1m,Probe size: Φ4mm*20mm
*Menu code description
Menu code | Specify | Explanation | Unit |
HC | Refrigeration/heating | Thermostat working mode set | H=Heating C=Cooling |
D | Return difference | Temperature difference between startup &shutdown | ℃ |
LS | Ultralow temperature | AL-L | ℃ |
HS | Ultra-temperature | AL-H | ℃ |
CA | Temperature correction |
| ℃ |
PT | Delay start | Minimum downtime | MInute |
Press the “SET”Key board and left screen flashes.Press “UP” and “ Down “key board to adjust temperature range,press right “UP” or “Down”key board (Any one) to preserve then exit.
Press twice “SET”board and right screen flashes, Press”UP” and “Down”Key board to adjust temperature,press right “UP” and “Down”board(any one) to preserve then exit.
Start and stop timing
Under the state of standby electric to press the “SET” once, start timing output ,screen alternately.
Press the “SET” Key board three seconds enter into the setting of control parameters.
Press up or down key board choose adjust menu . then press SET key board once again to enter into the related state of control parameter setting, press up or down key board to adjust parameters which requires modify. Press “SET” key board to exit after adjusted ,or exited from delayed 6 seconds system.
Cooling .heating mode setting
Press ”SET” key board less than 3 seconds ,enter into menu display, the code “HC” is displaying on screen, press “set” key board displayed working mode.Press”up or down”to adjust parameters .”C” means cooling mode ,”H” means heating mode.
Return difference function;
Maximum temperature was restricted with return difference between start up and close down.
Return difference setting.
Press ”SET” key board less than 3 seconds, enter into the menu display, press “up or down” key board to adjust code until screen displayed “D” code, press “SET” keyboard to displayed value of return difference. Press the “up or down” keyboard again to adjust parameters.
Temperature correction function
When there has deviations between measurement temperature and standard temperature. Machine measurement value and standard temperature can adjust to same under function of temperature correction. Temperature after correction=Temperature before correction +value of correction (Value of correction can be positive number ,negative number and zero)
Temperature correction setting.
Press ”SET” keyboard less than 3 seconds, enter into menu display, press“up or down” keyboard to adjust code until screen displayed “CA”, press ”SET” keyboard display temperature correction value, Press the “up or down” keyboard again to adjust parameters.
Delay protection function:
Press ”SET” Keyboard less than 3 minutes .enter into the menu display . press “up or down” keyboard to adjust code until screen displayed “PT”, Press “SET” keyboard displayed delay protection setting,Press the “up or down”keyboard again to adjust parameters.
Ultra-temperature alarm function
If measurement temperature ≥control temperature +AH alarm relay actuated , temperature controller alarming ,display screen alternated displaying “H” and present temperature. Then press anyone keyboards to stop alarming and turn off alarm relay output
Ultra-temperature alarm setting
Press “ SET” keyboard less than 3 seconds , enter into menu display,press“up or down”keyboard to adjust code until screen displayed “HS” .Press ‘SET” keyboard displayed the set value of ultra-temperature, press “up or down””keyboard again to adjust parameters , Set up “HS as “0”,you can turn off the alarm function.
Ultralow temperature alarm function
measurement temperature < control temperature-LS alarm relay actuated ,
temperature controller alerting . Display screen alternated displaying “L ”and present temperature ,press anyone keyboard and turn off relay output.
Ultralow temperature alarm setting
Press “SET” keyboard less than 3 seconds ,enter into menu display,press“up or down”” keyboard to adjust code until screen displayed “LS”, press ”SET” keyboard displayed the set value of ultralow temperature, press “up or down”” keyboard again to adjust parameters ,Set up “LS” as “0”,you can turn off the alarm function.
Status of the Indicator light introduction.
Green means working indicator light , green light long bright means state of cooling or heating. Red light flicking means delay to start up and it with function of setting.Red light long bright means in state of setting.
Press “SET” 3 seconds enter into system high ranking menu setting .During the progress of setting ,press ““up or down”” keyboard to choose menu which need to adjust.Then press “SET” keyboard once again enter into state of related controller parameters setting,,press ““up or down”” keyboard to adjust the controller parameters which need to modify,Exited by press ”SET” keyboard after adjustment.Temperature controller restart automatically.
Disturbance Display.
7.Caution
Connect to the correct working voltage ,machine is regular working within the range of ±10%standard input voltage
Connect to the power load less than maximum control power of temperature controller. If exceed please using with AC contactor.Connect to the correct power source ,load, sensor , temperature controller will damaged after connected to wrong wire.
Yueqing Kampa Electric Co.,Ltd. is Established in 1990.Has variety of goods ,such as Relay,Circuit breaker,Switches,Thermocouple,Thermostat,Temperature controller,Switch power supply,AVS,Heat sink,Heater,Distribution box,Junction box and so on.We are manufacturer and have ten years experience in Electrical industry.
A.Punctual delivery time:
We carry out your order into our well-organized production schedule, ensure your punctual delivery time.
Production report before your order packed.
Shipping notice and photos sent to you as soon as your order is shipped.
B.After sales service:
We Pay high Attention To Your Feed back after receive the goods.
We Provide 12 months warranty after goods arrive.
We Promise All Parts Available in lifetime use.
We Positively Revert Your Complain Within 48hours.
C.Professional Sales:
We value every Inquiry Sent To Us, Ensure Quick Competitive Offer.
We Cooperate With Customer To Bid Tenders. Provide all Necessary Documents.
We Are A Sales Team, With AllTechnical Support From Engineer Team.
Company Details
Ecer Certification:
Active Member
Yueqing Kampa Electric Co., Ltd. is Established in 1990.Has variety of goods,such as Relay,Circuit breaker,Switching Power Supply,Time Relay,Distribution Box,Proximity Switch, temperature controller, contactor, solid state relay, Mould Case Circuit Breaker, hour meter, electric power relay and so on... Yueqing Kampa Electric Co., Ltd. is Established in 1990.Has variety of goods,such as Relay,Circuit breaker,Switching Power Supply,Time Relay,Distribution Box,Proximity Switch, temperature controller, contactor, solid state relay, Mould Case Circuit Breaker, hour meter, electric power relay and so on...
Get in touch with us
Leave a Message, we will call you back quickly!