China factories

China factory - CITEST DIAGNOSTICS INC.

CITEST DIAGNOSTICS INC.

  • China,Hangzhou ,Zhejiang
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 100Ng/ML 95.9% Accurate Single Drug Abuse Test Kit Alprazolam Urine Detection
China 100Ng/ML 95.9% Accurate Single Drug Abuse Test Kit Alprazolam Urine Detection

  1. China 100Ng/ML 95.9% Accurate Single Drug Abuse Test Kit Alprazolam Urine Detection
  2. China 100Ng/ML 95.9% Accurate Single Drug Abuse Test Kit Alprazolam Urine Detection
  3. China 100Ng/ML 95.9% Accurate Single Drug Abuse Test Kit Alprazolam Urine Detection

100Ng/ML 95.9% Accurate Single Drug Abuse Test Kit Alprazolam Urine Detection

  1. MOQ: N/A
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 10 M tests/month
Delivery Time 2-4 Weeks
Packaging Details 40T/50T
Product 100 Ng / ML Accurate Alprazolam Single Drug Rapid Urine Test Medical Product
Cat. No. DALP-102/111/114
Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Cup
Specimen Urine
Certificate CE
Reading Time 5 minutes
Pack 40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 90.9%
Specificity 97.4%
Accuracy 95.9%
Cut-Off 100 ng/mL*
Brand Name Citest
Model Number DALP-102/111/114
Certification CE
Place of Origin -

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10 M tests/month Delivery Time 2-4 Weeks
Packaging Details 40T/50T Product 100 Ng / ML Accurate Alprazolam Single Drug Rapid Urine Test Medical Product
Cat. No. DALP-102/111/114 Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Cup Specimen Urine
Certificate CE Reading Time 5 minutes
Pack 40T/50T Storage Temperature 2-30°C
Shelf Life 2 Years Sensitivity 90.9%
Specificity 97.4% Accuracy 95.9%
Cut-Off 100 ng/mL* Brand Name Citest
Model Number DALP-102/111/114 Certification CE
Place of Origin -
High Light 95.9% Accurate Single Drug Abuse Test KitAlprazolam Single Drug Abuse Test Kit100Ng/ML Alprazolam Urine detection

100 ng/mL Panel/Cassette/Dipstick Accurate Alprazolam Single Drug Rapid Urine Test Medical Product

 

Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Cup
Specimen Urine
Certificate CE
Reading Time 5 minutes
Pack 40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 90.90%
Specificity 97.40%
Accuracy 95.90%
Cut-Off 100 ng/mL*

 

Application:

 

The ALP Rapid Test (Urine) is a rapid chromatographic immunoassay for the detection of alprazolam in urine at a cut-off concentration of 100ng/ml. This test will detect other related compounds, please refer to the Analytical Specificity table in this package insert.


This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

 

Description:

 

Alprazolam, available under the trade name Xanax among others, is a short-acting anxiolytic of the benzodiazepine class. It is commonly used for the treatment of panic disorder, and anxiety disorders, such as generalized anxiety disorder (GAD) or social anxiety disorder (SAD). Alprazolam, like other benzodiazepines, binds to specific sites on the GABAA receptor. It possesses anxiolytic, sedative, hypnotic, skeletal muscle relaxant, anticonvulsant, and amnestic properties.
 
A mean half-life of alprazolam of 16.3 hours has been observed in healthy elderly subjects (range: 9.0-26.9 hours, n=16) compared to 11.0 hours (range: 6.3-15.8 hours, n=16) in healthy adult subjects.Alprazolam and its metabolites are excreted primarily in the urine.
 
The pharmacokinetics of alprazolam and two of its major active metabolites (4-hydroxyalprazolam and α-hydroxyalprazolam) are linear, and concentrations are proportional up to the recommended maximum daily dose of 10 mg given once daily. Peak concentrations in the plasma occur in one to two hours following administration. Plasma levels are proportionate to the dose given; over the dose range of 0.5 to 3.0 mg, peak levels of 8.0 to 37ng/ml were observed.
 

How to use?

 

Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.

1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.

2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.

3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.
 

DIRECTIONS FOR PANEL USE


Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes

 

 

DIRECTIONS FOR DIPSTICK USE


Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

 

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

NEGATIVE:* Two lines appear. One colored line should be in the control line region (C), and another apparent colored line should be in the test line region (T). This negative result indicates that the Alprazolam(ALP) concentration is below the detectable cut-off level.

 

*NOTE: The shade of color in the test line region (T) may vary, but it should be considered negative whenever there is even a faint colored line.

 

POSITIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). This positive result indicates that the Alprazolam(ALP) exceeds the detectable cut-off level.

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DALP-102 Alprazolam(ALP) Rapid Test Cassette Urine Cassette 40 T 100 ng/mL* CE
DALP-114 Alprazolam(ALP) Rapid Test Panel Urine Panel 40 T CE
DALP-101 Alprazolam(ALP) Rapid Test Dipstick Urine Dipstick 50 T CE

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Total Annual:

    80000000-100000000

  • Employee Number:

    500~10000

  • Ecer Certification:

    Verified Supplier

CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ...

+ Read More

Get in touch with us

  • Reach Us
  • CITEST DIAGNOSTICS INC.
  • 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA
  • https://www.citesttestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement