China factories

China factory - CITEST DIAGNOSTICS INC.

CITEST DIAGNOSTICS INC.

  • China,Hangzhou ,Zhejiang
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Sensitive One Step Syphilis Rapid Test Kit In Home Diagnostic Testing
China Sensitive One Step Syphilis Rapid Test Kit In Home Diagnostic Testing

  1. China Sensitive One Step Syphilis Rapid Test Kit In Home Diagnostic Testing
  2. China Sensitive One Step Syphilis Rapid Test Kit In Home Diagnostic Testing
  3. China Sensitive One Step Syphilis Rapid Test Kit In Home Diagnostic Testing
  4. China Sensitive One Step Syphilis Rapid Test Kit In Home Diagnostic Testing

Sensitive One Step Syphilis Rapid Test Kit In Home Diagnostic Testing

  1. MOQ: N/A
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 10 M tests/month
Delivery Time 2-4 Weeks
Packaging Details 40T/50T
Product Sensitive One Step Syphilis Rapid Test Kit , Home Diagnosis Testing Kits
Cat. No. ISY-301/ISY-302/ISY-401/ISY-402
Principle Chromatographic Immunoassay
Format Dipstick, Cassette
Specimen WB/S/P
Certificate CE
Reading Time 5 minutes
Pack 40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Brand Name Citest
Model Number ISY-301/ISY-302/ISY-401/ISY-402
Certification CE
Place of Origin -

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10 M tests/month Delivery Time 2-4 Weeks
Packaging Details 40T/50T Product Sensitive One Step Syphilis Rapid Test Kit , Home Diagnosis Testing Kits
Cat. No. ISY-301/ISY-302/ISY-401/ISY-402 Principle Chromatographic Immunoassay
Format Dipstick, Cassette Specimen WB/S/P
Certificate CE Reading Time 5 minutes
Pack 40T/50T Storage Temperature 2-30°C
Shelf Life 2 Years Brand Name Citest
Model Number ISY-301/ISY-302/ISY-401/ISY-402 Certification CE
Place of Origin -
High Light One Step Syphilis Rapid Test KitSensitive Syphilis Rapid Test Kit5 minutes syphilis test kit

Sensitive One Step Syphilis Rapid Test Kit , Home Diagnosis Testing Kits

 

Product features Parameters
Principle Chromatographic Immunoassay
Format Dipstick, Cassette
Specimen WB/S/P
Certificate CE
Reading Time 5 minutes
Pack 40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years

 

Application:

 

The Syphilis Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to Treponema Pallidum (TP) in whole blood, serum or plasma to aid in the diagnosis of Syphilis.

 

Description:

Treponema Pallidum (TP) is the causative agent of the venereal disease Syphilis. TP is a spirochete bacterium with an outer envelope and a cytoplasmic membrane. Relatively little is known about the organism in comparison with other bacterial pathogens. According to the Center for Disease Control (CDC), the number of cases of Syphilis infection has markedly increased since 1985. Some key factors that have contributed to this rise include the crack coc/aine epidemic and the high incidence of prostitution among drug users.

 

One study reported a substantial epidemiological correlation between the acquisition and transmission of the HIV virus and Syphilis. Multiple clinical stages and long periods of latent, asymptomatic infection are characteristic of Syphilis. Primary Syphilis is defined by the presence of a chancre at the site of inoculation. The antibodies response to the TP bacterium can be detected within 4 to 7 days after the chancre appears. The infection remains detectable until the patient receives adequate treatment.


The Syphilis Rapid Test Cassette (Whole Blood/Serum/Plasma) utilizes a double antigen combination of a Syphilis antigen coated particle and Syphilis antigen immobilized on membrane to detect TP antibodies (IgG and IgM) qualitatively and selectively in whole blood, serum or plasma.

How to use?

 

For ISY-301:

Allow the test, specimen and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.

2. Method:
2.1 Transfer 150l serum or plasma to bottom of the test tube carefully. See the below illustration
2.2 With arrows pointing toward the serum or plasma specimen, immerse the test dipstick vertically into the specimen solution of the test tube and then start the timer. Do not pass the maximum line (MAX) on the test Dipstick when immersing the test dipstick. See the below
illustration
2.3 Leave the Dipstick in the test tube and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 20 minutes.

 

For ISY-302:

Allow the test, specimen and/or controls to reach room temperature (15-30°C) prior to testing.
 

1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
2. Place the cassette on a clean and level surface. Hold the dropper vertically and transfer 1 drop of serum or plasma (approx.40ul) to the specimen well of the test cassette, then add 1 drop of buffer (approx. 40ul) and start the timer. Avoid trapping air bubbles in the specimen well.
3. Wait for color line (s) appear. Read the result at 5 minutes, do not interpret the result after 20 minutes.

 

For ISY-401:

Allow the test, specimen, buffer and/or controls to reach room temperature (15- 30°C) prior to testing.

1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it as soon as possible.

2. Place the test cards on a clean and level desk, then peel off the strip label of the test cards, stick the test dipstick onto it as soon as possible before testing.

For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 40 ul) to the specimen area, then add 1 drop of buffer (approximately 40 ul),and start the timer, see illustration below.

For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 80 ul) to the specimen area, then add 1 drop of buffer (approximately 40 ul), and start the timer. See illustration below.

For Fingerstick Whole Blood specimen:
To use a capillary tube: Fill the capillary tube and transfer approximately 80 ul of fingerstick whole blood specimen to the specimen area of test dipstick, then add 1 drop of buffer (approximately 40 ul) and start the timer. See illustration below.

To use hanging drops: Allow 2 hanging drops of fingerstick whole blood specimen (approximately 80 ul) to fall into the specimen area of test dipstick, then add 1 drop of buffer (approximately 40 ul) and start the timer. See illustration below.
 

3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 20 minutes.

 

For ISY-402:
Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.

 

1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible.
 

2. Place the cassette on a clean and level surface.
For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 40 ul) to the specimen area, then add 1 drop of buffer (approximately 40 ul),and start the timer, see illustration below.
For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 80 ul) to the specimen area, then add 1 drop of buffer (approximately 40 ul), and start the timer. See illustration below.

 

For Fingerstick Whole Blood specimen:
· To use a capillary tube: Fill the capillary tube and transfer approximately 80 m mL of fingerstick whole blood specimen to the specimen area of test cassette, then add 1 drop of buffer (approximately 40 ul) and start the timer. See illustration below.
·To use hanging drops: Allow 2 hanging drops of fingerstick whole blood specimen (approximately 80 ul) to fall into the specimen area of test cassette, then add 1 drop of buffer (approximately 40 ul) and start the timer. See illustration below.

 

3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 20 minutes.

 

 

Order Information

 

Cat. No. Product Specimen Pack
ISY-301 Syphilis Rapid Test Dipstick S / P 50T
ISY-302 Syphilis Rapid Test Cassette S / P 40 T
ISY-401 Syphilis Rapid Test Dipstick WB/S/P 50T
ISY-402 Syphilis Rapid Test Cassette WB/S/P 40 T

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Total Annual:

    80000000-100000000

  • Employee Number:

    500~10000

  • Ecer Certification:

    Verified Supplier

CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ...

+ Read More

Get in touch with us

  • Reach Us
  • CITEST DIAGNOSTICS INC.
  • 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA
  • https://www.citesttestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement