Payment Terms | T/T |
Supply Ability | no limit |
Delivery Time | Normally 25 days after received the deposit. |
Packaging Details | 10 PC / Plastic Bag |
Durability | <0.3dB typical change, 200 matings |
Interchangeability | ≤0.2dB |
Tensile strength | >70N |
Plug -in times | >600 |
Operating Temperature (℃) | -40 to + 85°C |
Brand Name | HELLOSIGNAL® OR OEM |
Place of Origin | CHINA |
View Detail Information
Explore similar products
24 Fibers MTP OM3 Fiber Optic Loopback Module /Cable
8 Fibers MTP OM4 Fiber Optic Loopback Module /Cable
12 Fibers MTP OM4 Fiber Optic Loopback Module /Cable
24 Fibers MTP OM4 Fiber Optic Loopback Module Cable
Product Specification
Payment Terms | T/T | Supply Ability | no limit |
Delivery Time | Normally 25 days after received the deposit. | Packaging Details | 10 PC / Plastic Bag |
Durability | <0.3dB typical change, 200 matings | Interchangeability | ≤0.2dB |
Tensile strength | >70N | Plug -in times | >600 |
Operating Temperature (℃) | -40 to + 85°C | Brand Name | HELLOSIGNAL® OR OEM |
Place of Origin | CHINA | ||
High Light | Custom Meters MTP Fiber Patch Cord ,LSZH MTP Fiber Optic Patch Cord ,12 Fibers MTP Fiber Optic Patch Cord |
MPO Singlemode Reference: EIA/TIA-604-5
MPO Singlemode Housing Details: SM APC: Green connectors+black boot (Standard Loss MTP)
SM APC: Yellow connectors+black boot (Super low loss MTP)
MPO Multimode Reference: EIA/TIA-604-5
MPO Multimode Housing Details: OM1&OM2 PC: Beige connectors+black boot (Standard Loss MTP)
OM3&OM4 PC: Aqua connectors+black boot (Standard&Super low loss MTP)
OM3&OM4 PC: Heather Violet connectors+black boot (Standard loss MTP)
Insertion Loss (MPO)(IEC 61300-3-34)Singlemode (APC 8-degree polished): Standard loss:≤0.75dB(max), ≤0.50dB(Typical);Super Low loss:≤0.35dB(max), ≤0.20dB(Typical)
Insertion Loss(MPO)(IEC 61300-3-34) Multimode (PC Flat polish): Standard loss:≤0.6dB(max), ≤0.50(Typical);Super Low loss:≤0.35dB(max) , ≤0.20dB(Typical)
Insertion loss(LC/SC/FC/ST)(IEC 61300-3-6)Single mode (APC 8-degree polished): ≤0.3dB
Insertion loss(LC/SC/FC/ST)(IEC 61300-3-6)Multimode (PC Flat polish): ≤0.3dB
Return Loss (MPO) Singlemode (APC 8-degree polished): ≥60dB(8degree polishing)
Return Loss (MPO) Multimode (PC Flat polish): ≥25dB
Return loss(LC/SC/FC/ST): APC≥60dB; UPC≥50dB
Return loss(LC/SC/FC/ST): ≥35dB
Durability: <0.3dB typical change (200 matings)
Interchangeability: ≤0.2dB
Insert-pull Test: 500times, IL<0.5dB
Tensile strength: >70N
Plug -in times:>600
Operating Temperature Singlemode (APC): -40°C to +85°C
12F MPO- LC/SC/FC/ST Straight harness Cables designed for 40G LR4 PSM, 40GBASE-SR4, 40G QSFP+ PLR4 and highdensity data center. It is optimized for 10/40/100G high-density data center applications.
All of OMC’s MPO Connectors are from Senko/Nissin/Sumitomo. MPO Fiber Patch Cord is a kind of high density cable assemblies which is generally use in three areas.
Naming Rules&Order Confirmation Information:
Push Pull Tab For Senko MTP
MTP-MTP 12F Trunk cable drawing.
Overall Length(L)(m) | length of tolerance(cm) | |||||||
0<L<1 | +5/-0 | |||||||
1<L<10 | +10/-0 | |||||||
10<L<40 | +15/-0 | |||||||
40<L | ‘+0.5% x L/-0 |
Three Connection Methods Help Keep the Right MTP/MTP Polarity
1. Polarity A connection
Polarity A MTP cables use a key up, key down design. Therefore, as shown in the figure below, the position 1 of one
connector is corresponding to the position 1 of another connector. There is no polarity flip. Therefore, when we use polarity A MTP cable for connection, we must use A-B duplex patch cables on one end and A-A duplex patch cables on the other end. Since in this link, Rx1 must connect to Tx1. If we don’t use A-A duplex patch cable, according to the design principle of polarity A MTP cable, fiber 1 may transmit to fiber 1, that is to say Rx1 may transmit to Rx1, which may cause errors.
2. Polarity B connection
Polarity B MTP cables use a key up, key up design. Therefore, as shown in the figure below, the position 1 of one connector is corresponding to the position 12 of another connector. Therefore, when we use polarity B MTP cable for connection, we should use a A-B duplex patch cables on both ends. Since the key up to key up design help to flip the polarity, which makes fiber 1 transmit to fiber 12, that is the Rx1 transmits to Tx1.
3. Polarity C connection
Like the polarity A MTP cables, polarity C MTP cables also use a key up, key down design. However, within in the cable, there is a fiber cross design, which makes the position 1 of one connector is corresponding to the position 2 of
another connector. As shown in the figure below, when we use polarity C MTP cable for connection, we should use a A-B duplex patch cables on both ends. Since the cross fiber design help to flip the polarity, which makes fiber 1 transmit to fiber 2, that is the Rx1 transmits to Tx1.
Note: The Polarity type is in the following naming rules-Polarity A;Polarity B;Polarity C
Zion Communication's Hot TRUNK CABLE
This easily taken and well-protected fiber optical cable package has been labelled and marked by OMC as default .
Standard carton size : 34*22*15 cm; 44*34*24 cm ; 54*39*34 cm . Which carton to be used depends on goods Qty .
Packing can be customized.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1999
Total Annual:
80 Million-100 Million
Employee Number:
400~500
Ecer Certification:
Verified Supplier
Zion Communications is a professional manufacturer and supplier of the products for fiber systems & copper cabling systems. We provide products and services to our customers in 2 ways. 1, OEM customized production according to your requirements 2, Standardized products and services accordi... Zion Communications is a professional manufacturer and supplier of the products for fiber systems & copper cabling systems. We provide products and services to our customers in 2 ways. 1, OEM customized production according to your requirements 2, Standardized products and services accordi...
Get in touch with us
Leave a Message, we will call you back quickly!