Payment Terms | T/T |
Supply Ability | 10 sets/day |
Delivery Time | 1-2weeks |
Packaging Details | Reinforced Carton box with wooden tray |
key word | Intelligent control Air Conditioning ASHPs |
Compressor capacity | 6Hp ~25HP |
Function | cooling and heating |
Noise level | 62dba |
Compressor brand | Copeland |
Electricity | 380V-3P-50hz |
Working conditions | -25C ~+45C |
Brand Name | Yushen |
Model Number | 017Y~075Y |
Certification | CCC, ISO, CQC |
Place of Origin | China |
View Detail Information
Explore similar products
62 DBA Air Source Central Air Conditioner Heat Pump , Heating And Cooling Units
62 Dba Air Cooled Heat Pump Scroll Compressors 40 % Energy Saving
6P - 25P Air Energy Heat Pump , School Central Air Conditioning System
6000 Sqm Central Air Conditioner Heat Pump Apply To Rural Area Villages
Product Specification
Payment Terms | T/T | Supply Ability | 10 sets/day |
Delivery Time | 1-2weeks | Packaging Details | Reinforced Carton box with wooden tray |
key word | Intelligent control Air Conditioning ASHPs | Compressor capacity | 6Hp ~25HP |
Function | cooling and heating | Noise level | 62dba |
Compressor brand | Copeland | Electricity | 380V-3P-50hz |
Working conditions | -25C ~+45C | Brand Name | Yushen |
Model Number | 017Y~075Y | Certification | CCC, ISO, CQC |
Place of Origin | China | ||
High Light | central heating and air conditioning units ,heat pump air conditioning unit |
Intelligent Control Heat Pump Air Source For Central AC Freon R22
Units Characters
1,Iintelligent management
◆ The unit adopts the microcomputer touch control system to provide the simplest and most thoughtful operation interface and timely feedback of various maintenance information.
◆ The unit control system can be connected to the user's central control system, and the customer can understand the unit's operation at all times.
2 Easy to install and maintain
◆ The unit has been filled with refrigerant and lubricating oil before leaving the factory. The customer only needs to connect the inlet and outlet pipes and the power supply to run.
◆ The control interface directly displays the fault content, which is convenient for timely understanding of the fault and elimination.
3.a variety of refrigerant options to meet the different needs of customers
The unit can also provide R22, R407C, R404a and other refrigerants according to customer needs.
Parameter of central AC ASHP
A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃
a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal
Model | SLNA-017Y | SLNA-032Y | SLNB-035Y | SLNB-047Y | SLNC-075Y | |||
Compressor capacity | 6HP | 10HP | 12.5HP | 15HP | 25HP | |||
Function | Heating and Cooling | Heating and Cooling | Heating and Cooling | Heating and Cooling | Heating and Cooling | |||
Electricity | 380V-3N-50Hz | 380V-3N-50Hz | 380V-3N-50Hz | 380V-3N-50Hz | 380V-3N-50Hz | |||
Working conditions | ℃ | -25~~+45 | -25~+45 | -25~+45 | -25~+45 | -25~+45 | ||
Data | Heata | Nominal capacity | KW | 12 | 21.5 | 22.3 | 28.1 | 44.5 |
Input power | KW | 4.55 | 9.1 | 9.4 | 11.7 | 18.3 | ||
COP | / | 2.4 | 2.3 | 2.35 | 2.4 | 2.4 | ||
Heating IPLV(H) | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | |||
Coolb | Nominal capacity | KW | 14 | 25 | 28 | 39 | 62 | |
Input power | KW | 5 | 10 | 10.4 | 13.1 | 20.7 | ||
COP | / | 2.5 | 2.5 | 2.7 | 2.9 | 3 | ||
Cooling IPLV(C) | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | |||
A7W35c | KW/COP | 19.5/4.21 | 32.0/4.1 | 35.0/4.1 | 47.0/4.1 | 75.0/4.2 | ||
A2W35 | KW/COP | 27/3.60 | 27/3.60 | 28.5/3.60 | 39.5/3.20 | 62.5/3.20 | ||
A-7W35 | KW/COP | 21.5/2.8 | 21.5/2.8 | 23.5/2.9 | 32/2.9 | 50/2.9 | ||
A-15W55 | KW/COP | 19.7 /1.94 | 19.7 /1.94 | 20.2 /1.94 | 28.1/1.94 | 45.5 /1.97 | ||
A-20W45 | KW/COP | 18.1/2.02 | 18.1/2.02 | 18.7/2.02 | 23.6/2.03 | 37.4/2.04 | ||
Max. running currency | A | 25 | 25 | 27 | 35 | 56 | ||
Compressor quantity | set | 2 | 2 | 1 | 2 | 2 | ||
Refrigerant/charging quantity kg | / | R22/4.8 | R22/3.7*2 | R22/9 | R22/10 | R22/15*2 | ||
Air blow type | / | Side | Top | Side | Top | Top | ||
Water pipe diameter | mm | G1.2〞 | 32 | 32 | 50 | 50 | ||
Rating flow | m³/h | 3.2 | 5.5 | 5.9 | 8.3 | 12.6 | ||
Water side pressure loss | kPa | ≤45 | ≤45 | ≤45 | ≤45 | ≤45 | ||
Noise level | dB(A) | 62 | 62 | 62 | 62 | 62 | ||
Overall dimensions(L×W×H) | mm | 1120×440×1360 | 1530×750×1370 | 1490×900×1900 | 1450×1100×2080 | 2100×1100×2080 | ||
Weight | kg | 130 | 320 | 350 | 470 | 730 |
Yushen Products Advantages
Our service
Company Details
Business Type:
Manufacturer
Year Established:
2014
Total Annual:
7000000-12000000
Ecer Certification:
Active Member
Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ... Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ...