China factories

China factory - Zhengzhou Linker Medical Equipment Co., Ltd.

Zhengzhou Linker Medical Equipment Co., Ltd.

  • China,Zhengzhou ,Henan
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China CE FDA Virus 20 Minutes Rapid Antigen Test Kit
China CE FDA Virus 20 Minutes Rapid Antigen Test Kit

  1. China CE FDA Virus 20 Minutes Rapid Antigen Test Kit
  2. China CE FDA Virus 20 Minutes Rapid Antigen Test Kit
  3. China CE FDA Virus 20 Minutes Rapid Antigen Test Kit

CE FDA Virus 20 Minutes Rapid Antigen Test Kit

  1. MOQ: 1000pcs
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, Western Union, MoneyGram, RMB
Supply Ability 40.000pcs/day
Delivery Time 2-3 working days
Packaging Details 25pcs/box, 100box/carton
Name Antigen Test Kit
Used for throat swab/ nasopharyngeal swab
Testing Time 20 minutes
Certificate CE/FDA/CDC Test
Expire Date 2 years
Pack 25pcs/box
Brand Name Deepblue
Model Number COVID-19 Antigen Test
Certification CE,ISO,FDA
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, MoneyGram, RMB Supply Ability 40.000pcs/day
Delivery Time 2-3 working days Packaging Details 25pcs/box, 100box/carton
Name Antigen Test Kit Used for throat swab/ nasopharyngeal swab
Testing Time 20 minutes Certificate CE/FDA/CDC Test
Expire Date 2 years Pack 25pcs/box
Brand Name Deepblue Model Number COVID-19 Antigen Test
Certification CE,ISO,FDA Place of Origin China
High Light 20 Minutes Rapid Antigen Test KitCE Rapid Antigen Test Kit20 Minutes rapid strep antigen test

Covid-19 (SARS-CoV-2) Virus Rapid Antigen Test Kit CE FDA Approved

 

Limitations of inspection methods:
1. This test kit is only used for in vitro diagnosis.
2. This test kit is only used to detect human throat or nasal swab extracts. The results of other specimens may be wrong.
3. This test kit is only used for qualitative detection and cannot indicate the level of SARS-CoV-2 antigen in the specimen.
4. This test kit is only a clinical auxiliary diagnostic tool. If the result is positive, it is recommended to use other methods for further examination in time and the doctor’s diagnosis shall prevail.

 

Materials provided:
1) Sterilized Swab
2) Antigen extraction tube
3) Extraction Reagent
4) Test device

 

Materials required but not provided:Timer.


[Storage conditions & period of validity]
1. Store at 4℃~30℃, and it is valid for 24 months.
2. After the aluminum foil bag is unsealed, the test device should be used as
soon as possible within one hour.

 

Storage and Expiry: 

Room Tempreture 4-30 degree
Weather Request Dry and no light, no freeze
Expiry Date 24 months

 

Specimen Collection:
1. Pharyngeal swab Sample:
Let the patient's head tilt slightly, mouth open, and make "ah" sounds, exposing the pharyngeal tonsils on both sides. Hold the swab and wipe the pharyngeal tonsils on both sides of the patient with a little hard back and forth at least 3 times.
2. Nasal swab Sample:
Let the patient's head relax naturally, and slowly rotate the swab against the wall of the nostril into the patient's nostril to the nasal palate, and then slowly remove it while wiping. Using the same swab, wipe the other nostril in the same way;

 


Sample Transport and Storage:
After Swab specimens were collected, swab can be stored in extraction reagent provided with the kit. Also can be stored by immersing the swab
head in a tube containing 2 to 3 mL of virus preservation solution (or isotonic saline solution, tissue culture solution, or phosphate buffer).
Freshly collected specimens should be processed as soon as possible, but no later than one hour after specimen collection. Specimen collected may be stored at 2-8℃for no more than 24 hours; Store at -70 ℃for a long time, but avoid repeated freeze-thaw cycles.

 

Specimen Preparation:

1. Take out the extraction tube, add 8 drops (about 0.3 mL) of the extraction reagent into the extraction tube, and put it on the workbench.
2. Put the swab specimen into the extraction tube, rotate the swab for about 10 seconds, and press the swab head against the tube wall to release the antigen in the swab.
3. Remove the swab while squeezing the sides of the tube to extract the liquid from the swab. so as to remove as much liquid as possible from the swab. Dispose of swabs according to biohazard waste disposal method.
4. Insert a dropper tip into the extraction tube tightly.

 

Test Procedure:
Read the instructions carefully before use and bring test device, extraction reagent and specimens were restored to room temperature.
1. Open the package and take out the test device.
2. Insert a dropper tip into the extraction tube tightly, put two drops into the specimen well (s) of the test device, and start the timer.
3. Interpret the results within 20 minutes. Strong positive results can be reported within 20 minutes, however, negative results must be reported after 20 minutes, and the results after 30 minutes are no longer valid.

 

Interpretation of test results:
Negative result: if there is only a quality control line C, the detection line T is colorless, indicating that SARS-CoV-2 antigen has not been detected and the result is negative.
Positive result: if both the quality control line C and the detection line T appear, indicating that SARS-CoV-2 antigen has been detected and the result is positive.
Invalid result: if the quality control line C is not observed, it will be invalid regardless of whether there is detection line T (as shown in the figure below), and the test shall be conducted again

 

More Contact Information:

Echo Chai (Miss) ---Export Department
Zhengzhou Linker Medical Equipment Co., Ltd.
Web: www.zzlinker.com
E-mail/Skype: sale@zzlinker.com
Tel: +86 371 63937550
Whatsapp/Wechat: +86 18860361012

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Year Established:

    2007

  • Employee Number:

    >100

  • Ecer Certification:

    Active Member

Zhengzhou Linker Medical Equipment Co., Ltd. is located in Zhengzhou, central area of China, a traditional commerce city with rich history and culture. Since 2007, our company has been focusing on dental products export, including dental equipments and materials, dental cultural products and elec... Zhengzhou Linker Medical Equipment Co., Ltd. is located in Zhengzhou, central area of China, a traditional commerce city with rich history and culture. Since 2007, our company has been focusing on dental products export, including dental equipments and materials, dental cultural products and elec...

+ Read More

Get in touch with us

  • Reach Us
  • Zhengzhou Linker Medical Equipment Co., Ltd.
  • No 57, Sicence Avenue, Zhengzhou, China
  • https://www.dental-chair-unit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement