Payment Terms | L/C, D/P, T/T |
Supply Ability | 100000pcs per Month |
Delivery Time | 15days or Depends on ordering QTYS |
Packaging Details | Each unit be packed in one individual inner box |
Rated heating current | 32A |
Rated insulation voltage | 690V |
Poles | 3 |
Standard | IEC60947 |
Auxiliary contact | NO/NC |
Coil | AC |
Protection degree | IP20 |
Pollution degree | class 3 |
Brand Name | YOKG |
Model Number | SC18 |
Certification | CE,TUV,CB |
Place of Origin | China |
View Detail Information
Explore similar products
GC-12 50Hz 60Hz 3 Phase AC Electric Contactor 25A 220V 40A
LA1 - DN11 NO NC AC Electric Contactor Auxiliary Contact Block 380V
440V AC Electric Contactor With Red Copper For Overload Industrial
3P NO AC DC Contactor 3P+NO+NC 20A 32A 40amp 380V 660vac
Product Specification
Payment Terms | L/C, D/P, T/T | Supply Ability | 100000pcs per Month |
Delivery Time | 15days or Depends on ordering QTYS | Packaging Details | Each unit be packed in one individual inner box |
Rated heating current | 32A | Rated insulation voltage | 690V |
Poles | 3 | Standard | IEC60947 |
Auxiliary contact | NO/NC | Coil | AC |
Protection degree | IP20 | Pollution degree | class 3 |
Brand Name | YOKG | Model Number | SC18 |
Certification | CE,TUV,CB | Place of Origin | China |
High Light | IEC60947 AC Electric Contactor ,32A AC Electric Contactor 690V SC18 ,IEC60947 SC18 32A 690V AC 32 amp contactor |
YOKG SC Series AC Electric Contactor 20A 690V 3poles Black Contactor
Application:
SC series AC contactors are mainly used for AC 50Hz / 60Hz.rated voltage up to 660V and rated current up to 95A for remote switch, breaking and frequent starting, controlling the AC motor. Moreover, the contactor can act as the time-delay contactor, reversible contactor, star-delta starter by the accessories addition such as addition of modular auxiliary contact set. Air time delay head, mechanical interlock mechanism, etc. Moreover,it could act as the electromagnetic starter by the direct plug of the thermal relay.
This series contactor complies with GB 14048, IEC60947-4-1
Main parameters and Technical Performance:
Type | SC18 | ||
Rated heating current (A) | 32 | ||
Rated insulation voltage (V) | 690 | ||
Rated impact withstand voltage (KV) | 6 | ||
Rated making capacity | 10le | ||
Rated breaking capacity | 8le | ||
Poles | 3 | ||
Auxiliary contact | NO/NC | ||
Short-time withstand current(A) | 10S | 144 | |
Rated working current(A) | 380V | AC-3 | 18 |
AC-4 | 7.7 | ||
660V | AC-3 | 12 | |
AC-4 | 3.8 | ||
AC-3 capacity of phase 3 squirrel-cage motor (AC-3) KW | 220V | 4 | |
380V | 7.5 | ||
660V | 10 | ||
Operation frequency (times/h) | Electrical life | AC-3 | 1200 |
AC-4 | 300 | ||
Mechanical life | 3600 | ||
Electrical life (10000/times) | AC-3 | 100 | |
AC-4 | 20 | ||
Mechanical life (10000/times) | 1000 | ||
Equipped fuse type | RT16-32 | ||
Rated control supply voltage Us(V) | 50/60Hz | 12~480 | |
Operation range | Pull-in | (85%~110%)Us +40℃ | |
Releasing | (20%~75%)Us -5℃ | ||
Ac coil average power(VA) | Start | 70 | |
Keeping | 8 | ||
Power efficiency class | class 3 | ||
Thermal loss(W) | 2~3 | ||
Actuation time(ms) | Close | 12~25 | |
Break | 5~20 | ||
Main circuit wiring | flexible wire without cold pressing terminal (㎟) | 1 stick | 1.5~6 |
2 sticks | 1.5~6 | ||
flexible wire with cold pressing terminal (㎟) | 1 stick | 1~6 | |
2 sticks | 1~4 | ||
Hard wire (㎟) | 1 stick | 1.5~6 | |
2 sticks | 1.5~6 | ||
Fastening screw size | M3.5 | ||
Tightening fastening torque (N.m) | 0.8 | ||
Control loop wiring | flexible wire without cold pressing terminal (㎟) | 1 stick | 1~4 |
2 sticks | 1~4 | ||
flexible wire with cold pressing terminal (㎟) | 1 stick | 1~4 | |
2 sticks | 1~2.5 | ||
Hard wire (㎟) | 1 stick | 1~4 | |
2 sticks | 1~4 | ||
Fastening screw size | M3.5 | ||
Tightening fastening torque (N.m) | 0.8 |
Model and Implication:
Working and Installation Condition:
Ambient air temperature: -5℃--+40℃ and average not more than +35℃ within 24 hours;
Altitude: ≤ 2000m;
Air condition: when the highest temperature is +40℃, the air relative humidity is not up to 50%, but the higher humidity is allowed at lower temperature. Like, 90% humidity at 20℃. The condensate dew should be considered when at lower temperature;
Pollution degree: Class 3
Installation category:III
Protection degree: IP20
Installation condition: the gradient angle between installation side and vertical side should not be more than ±5℃
Impact and vibrattion: the contactor must be installed and operate under the circumstances of no obvious shaking, impact and vibration.
Structure characteristic:
It can be installed with auxiliary contacts block, time relay and current-limited contacts block, and thermal relay, then to be other derivative products;
This series contactor has small volume, light weight, less power loss, long life and safe and reliability etc;
The contactor can be equipped with 1NO auxiliary contact or 1NC auxiliary contact(less than 32A), and 1NO auxiliary contact+1NC auxiliary contact(more than 40A). In addition, it can be equipped with F4 auxiliary contactor block (2blocks or 4blocks);
In addition to use screw to install, contactor can be tightened with the standard installing rail of 35mm (sc09~95) and the standard installing rail of 75mm(SC40~95)
Installation dimension:
A max | B max | C max | a | b | ∅ |
47 | 76 | 87 | 34/35 | 50/60 | 4.5 |
Company Details
Business Type:
Manufacturer
Year Established:
1999
Total Annual:
7.5 Million -8 Million
Employee Number:
50~70
Ecer Certification:
Verified Supplier
We, Yueqing Zeyi electrical Co., Ltd. is intended on creating a professional contactor manufacturing enterprise. Adhere to this business concept, have been focusing on the contactor industry for nearly 20 years, concentrate on the design and manufacture of CJX2 (WC1) series products. N... We, Yueqing Zeyi electrical Co., Ltd. is intended on creating a professional contactor manufacturing enterprise. Adhere to this business concept, have been focusing on the contactor industry for nearly 20 years, concentrate on the design and manufacture of CJX2 (WC1) series products. N...
Get in touch with us