China 500V Screw Industrial Fuse Holder 25A Low Voltage AC 50Hz
China 500V Screw Industrial Fuse Holder 25A Low Voltage AC 50Hz

  1. China 500V Screw Industrial Fuse Holder 25A Low Voltage AC 50Hz

500V Screw Industrial Fuse Holder 25A Low Voltage AC 50Hz

  1. MOQ: 5000pcs
  2. Price:
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union
Supply Ability 2000 Piece/Pieces per Day
Delivery Time 15 DAYS AFTER PAYMENT
Packaging Details Standard Export Carton Package
Rated Voltage 500V
Rated Current 25A
Fuse Link Size E27
Type Screw Fuse Links
Breaking Capacity up to 100KA
Material Copper, Porcelain or Brass
Usage Low Voltage
Function grade gG / gL / aR / aM
Brand Name OEM
Model Number E27
Certification CE,TUV,CB,RoHS
Place of Origin ZHEJIANG,CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union Supply Ability 2000 Piece/Pieces per Day
Delivery Time 15 DAYS AFTER PAYMENT Packaging Details Standard Export Carton Package
Rated Voltage 500V Rated Current 25A
Fuse Link Size E27 Type Screw Fuse Links
Breaking Capacity up to 100KA Material Copper, Porcelain or Brass
Usage Low Voltage Function grade gG / gL / aR / aM
Brand Name OEM Model Number E27
Certification CE,TUV,CB,RoHS Place of Origin ZHEJIANG,CHINA
High Light 500V Screw Industrial Fuse HolderIndustrial Fuse Holder 25AAC 50Hz Industrial Fuse Holder

Fuse Links Selection Guide:
 
The purpose of using fuses is to out off the line safely and correctly to protect discrete components or the whole line in case of circuit errors. The following are the necessary conditions to be considered when selecting fuses.
 
Usual Service Conditions and Installation Conditions:

  1. Ambient temperature:-5℃~+40℃
  2. Height above sea level not more than 2000m.
  3. Atmospheric condition: humidity: the installation site's relative air humidity does not exceed 50% while the maximum temperature is +40'C. And it can allow to have higher relative humidity under lower temperature. The average temperature does not exceed +25C while in the wettest month, and the maximum relative humidity does not exceed 90%in this month. We must take measures when there is condensation on the products which due to the changed temperature.
  4. Class of pollution: Third class
  5. Sort of installation: III

Malfunction:
 
Malfunction is usually a result of incomplete analysis on the design of circuit, Special attention should be given to 1) normal rated current; 3) Ambient temper- ature; and 6)overload increasement of factors to be considered for selection of fuses listed below. For example, frequent reasons for malfunction under normal working conditions are insufficient consideration to the start current of capacitor circuit and the ambient temperature around the fuse link.
 
Rated breaking capacity:
 
Rated breaking capacity is the maximum short-circuit current allowed for the fuse link to cutout reliably under rated voltage. The instantaneous current loaded to the fuse link is much larger than the normal working current when short-circuit occurs. The fuse link is supported to cutout the line in an undamage condition i.e. without bursting. The rated breaking capacity of TIRH fuses is up to 120KA and the excellent current limiting characteristics reliably protect the equipment form damages by electric power.

 

Screw Base Type Fuse Links(R021 E27,R022 E33,D02 E14) Fuse Links
Applications:
This series of fuse links is mainly used in AC 50Hz,rated voltage up to 690V, rated current up to 125A and for pro- tecting electric equipment from overload and short-circuit. It can reliably break the min fusion current to any current wit- hin 120KA.
It is also available for the protection of semiconductor parts and equipments against short-circuittype aR)and prote- ction of motors(type aM).This series of fuse links conforms to GB13539 and IEC 60269 standards.
 
Design Features:
Variable cross-section fuse element made from pure metal sealed in cartridge made from high-duty ceramic. Fuse tu be filled with chemically treated high-purity quartz sand as arc-extinguishing medium,Indicator springs out when fuse cuts to give caution.According to the demand of customers we can also produce special fuse.
 
Technical Specification:

Code No. Product model Domestic and oversea similar prodcts Rated Voltage(V) Rated current(A) Overall dimension (mm)
A ΦD1 ΦD2 ΦD3
18085 RO21 5SB E27 RL6-25 500 2~6 50 22 13 6
8~10 50 22 13 8
13 50 22 15 8
16 50 22 15 10
20 50 22 15 12
25 50 22 15 14
18086 RO22 5SB E33 RL6-63 500 30-40 50 27 20 16
50 50 27 20 18
63 50 27 20 20
18087 RO24 E16 5SA 500 2~6 50 12.5 11.3 6
10 50 12.5 11.3 8
16 50 12.5 11.3 10
20 50 12.5 11.3 12


 

Code No. Product model Domestic and oversea similar prodcts Rated Voltage(V) Rated current(A) Overall dimension (mm)
A ΦD1 ΦD2 ΦD3
18088 RO26 E14
RL18
5SE
E18
400 2~6 36 7.3 10 5
10 36 8.5 10 5
18 36 9.7 10 8.5
400 20 36 11 14 8.5
25 36 12 14 8.5
35 36 13.3 14 8.5
50 36 14.5 14 8.5
63 36 16 14 8.5
400 80 43 22 21 17
100 43 25 21 17

 

 

Factors To Be Considered For Selection of Fuses:

  1. Normal working current
  2. Working voltage
  3. Ambient temperature
  4. Overload current and cutout time
  5. Possible malfunction current
  6. Impulse current, surge current, starting current and transient value of the line
  7. Size and dimensions, connection methods, indicators, etc.

Ambient Temperature:
Ambient Temperature means the air Temperature directly around the fuse, and should not be understood as the room temperature. In many application cases, the fuses are at rather high temperature as they are installed with supporting devices or bases in different structures and they are closed in the distributing or controlling boxes.
 
Further information:
1. Plastics materials: all raw materials are brand-new and second-hand materials are forbidden. Furthermore some of them are supplied by super branding companies like DSM, Mitsubishi.
2. There is just one level of quality as A in MEIHENG and we are aim to provide the excellent articles to our clients and help them gain more market shares.
3. ODM: we are providing ODM services to the super companies (more than 15) who are top-10 electrical industrial companies in their country. Just show us your ideas and we will present a solution.
FAQ
A. How's the delivery time?
Depend on your quantity, usually within 20days after receiving deposit
B. Would you accept OEM/ODM service?
Glad to say that there is planning department, technical department and mould tooling center in
our factory. For the OEM & ODM, it is ok for us if your brand, market shares are great.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2000

  • Total Annual:

    3,000,000-3,500,000

  • Employee Number:

    150~200

  • Ecer Certification:

    Active Member

Wenzhou MEIHENG Electric Co., Ltd. founded in 2000 is specialized in Rotary Cam Switch,Rotary Changeover Switch,Rotary Selector Switch,Isolator Switch,Push Button Switch, industrial plug socket,Analog Panel Meter,Digital Panel Meter,DIN-RAIL Energy Meter, Low Voltage Fuse,Fuse Holder and others. ... Wenzhou MEIHENG Electric Co., Ltd. founded in 2000 is specialized in Rotary Cam Switch,Rotary Changeover Switch,Rotary Selector Switch,Isolator Switch,Push Button Switch, industrial plug socket,Analog Panel Meter,Digital Panel Meter,DIN-RAIL Energy Meter, Low Voltage Fuse,Fuse Holder and others. ...

+ Read More

Get in touch with us

  • Reach Us
  • WENZHOU MEIHENG ELECTRIC CO.,LTD
  • Xiangyang Industrial Zone,Liushi Town,Yueqing City,Zhejiang Province,325604,P.R.China
  • https://electricalrotaryswitch.ecer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement