Payment Terms | L/C, T/T |
Supply Ability | 50 sets per month |
Delivery Time | 45 work days |
Packaging Details | wooden case |
color | grey (customized) |
MES connection | Yes |
Service | 24 hours quick response |
Monitor | 5.7" monitor |
Data exportation | support USB flash drive exportation |
product name | Electrical Testing System of appliances supporting MES |
Brand Name | AIP |
Model Number | AIP89XX |
Place of Origin | China |
View Detail Information
Explore similar products
Electrical Safety Testing System 5.7" LCD Monitor For Home Appliances
High Precision Ground Testing Equipment For Production Line And Laboratory
Electrical Safety Testing System AC Hipot Test With 19" LCD Monitor
Three - Phase Safety Quality Inspection Equipment Reliable High Performance
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 50 sets per month |
Delivery Time | 45 work days | Packaging Details | wooden case |
color | grey (customized) | MES connection | Yes |
Service | 24 hours quick response | Monitor | 5.7" monitor |
Data exportation | support USB flash drive exportation | product name | Electrical Testing System of appliances supporting MES |
Brand Name | AIP | Model Number | AIP89XX |
Place of Origin | China | ||
High Light | electrical safety test equipment ,laboratory testing equipment ,Quick Response Electrical Safety Equipment |
Safety Testing System / Electrical Testing System of appliances supporting MES
1. Application industry: home appliances & electric appliances such as air conditioner, refrigerator, washing machine, TV etc.
2. Test items: ground resistance, leakage current, insulation resistance, low voltage start, power, AC Hipot, DC withstand voltage
3. Technical parameters:
AC Hipot | |
Output voltage setting range/precision | AC 200~5000V ±(1.5%*setting value + 5 digit) |
Breakdown current measuring range/precision | 0.10~99.99mA ±(1.5%*displayed value + 5 digit) |
Presetting breakdown current alarm range/precision | Up limit: 0.10~99.99mA; |
Testing time range/resolution | 1~300S 1s/step |
DC withstand voltage | |
Output voltage setting range/precision | DC 200~5000V ±(1.5%*setting value + 5 digit) |
Breakdown current measuring range/precision | 0.10~10.00mA ±(1.5%*displayed value + 5 digit) |
Presetting breakdown current alarm range/precision | Up limit: 0.10~10.00mA; |
Testing time range/resolution | 1~300S 1s/step |
Insulation resistance | |
Output voltage setting range/precision | DC 500/1000V ±(1.5%*displayed value + 5 digit) |
Insulation resistance measuring range/precision | 1~2000MΩ Within 100MΩ:±(5%*displayed value + 3 digit); |
Presetting insulation resistance alarm range/precision | Up limit: 0~2000MΩ; Lower limit: 1~2000MΩ |
Testing time range/resolution | 1-300s 1s/step |
Grounding | |
Ground current output range/precision | AC 5.0~30.0A ±(1.5%*setting value + 5 digit) |
Ground resistance measuring range/precision | 10.0~600mΩ±(1.5%*displayed value + 5 digit) |
Presetting ground resistance alarm range | Up limit: 5~10A 10.0~600mΩ; 11~25A 10.0~300mΩ; 26~30A 10.0~200mΩ |
Testing time/resolution | 1~60s 1s/step |
Leakage current | |
Output voltage | 1.06 times of nominal voltage |
Setting of leakage type | Dynamic leakage, static leakage, built-in body impedance network is optional, customized is available. |
Output voltage measuring range/precision | AC 50~280V ±(0.5%*displayed value + 2 digit) |
Leakage current measuring range/precision | 0.05~20.00mA ±(1.5%*displayed value +0.02mA) |
Presetting leakage current alarm range | Up limit: 0.05~20.00mA; Lower limit: 0.01~5.00mA |
Testing time range/resolution | 1~300s 1s/step |
power | |
Output voltage | Equals input voltage |
Output voltage measuring range/precision | AC 50~500V ±(0.5%*displayed value + 2 digit) |
Output current measuring range/precision | AC 0.20~40.00A ±(0.5%*displayed value + 2 digit) |
Power measuring range/precision | 30~20000W ±(0.5%*displayed value + 5 digit) |
Presetting power alarm range | Up limit: 30~20000W; Lower limit: 0~20000W |
Testing time/resolution | 1~300s 1s/step |
Low voltage start | |
Output voltage | O.85 times of input voltage |
Output voltage measuring range/precision | AC 50~500V ±(0.5%*displayed value + 2 digit) |
Starting current measuring range/precision | AC 0.20~40.00A ±(0.5%*displayed value + 2 digit) |
Presetting current alarm range | Up limit: 0.20~40.00A; Lower limit: 0.00~25.00A |
Testing time/resolution | 1~300s 1s/step |
Accessories: power cord*1, foot switch*1(30A), clamp*2, test box1, input power wire*1, fuse tube*1.
4. Tips of electrical safety test
4.1 Attentions during dynamic leakage current measurement:
4.2 Attentions for the ground conduction resistance measurement:
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2009
Employee Number:
100~200
Ecer Certification:
Site Member
Qingdao AIP Intelligent Instrument Co., Ltd., a leading provider of motor testing machine. Founded as a professional company for producing motor testing machine in 2009, AIP has developed to one of the leading manufacturers of this industry in China. Our products can be applied to control the... Qingdao AIP Intelligent Instrument Co., Ltd., a leading provider of motor testing machine. Founded as a professional company for producing motor testing machine in 2009, AIP has developed to one of the leading manufacturers of this industry in China. Our products can be applied to control the...
Get in touch with us
Leave a Message, we will call you back quickly!