Payment Terms | L/C, T/T, Western Union |
Supply Ability | 500 Set/ Year |
Delivery Time | 15~30 days |
Packaging Details | container |
Name | Escalator |
Speed | 0.5m/s |
Motor Capacity | 5.5kw |
Traveling Height | 1000-3000mm |
Net Weight | 67kn |
Type | Heavy |
Usage | Car Elevators |
Flooring | PVC/marble |
Product | Escalator |
Model | Escalator |
Brand Name | SUNNY |
Model Number | Escalaror |
Certification | CE,ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
Small Machine Room High Speed Lift Energy Saving With Compact Structure
Sightseeing High Speed Elevator Stainless Steel Panoramic Elevator For Passenger
High Efficient Industrial Freight Elevator Reliable For Goods / Cargo
Medical Patient Hospital Bed Lift Car Size 1400 * 2400 * 2500mm With Low Noise
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 500 Set/ Year |
Delivery Time | 15~30 days | Packaging Details | container |
Name | Escalator | Speed | 0.5m/s |
Motor Capacity | 5.5kw | Traveling Height | 1000-3000mm |
Net Weight | 67kn | Type | Heavy |
Usage | Car Elevators | Flooring | PVC/marble |
Product | Escalator | Model | Escalator |
Brand Name | SUNNY | Model Number | Escalaror |
Certification | CE,ISO9001 | Place of Origin | China |
High Light | high speed lift ,airport walking escalator |
Public Economical Heavy Duty Escalator Traveling Height 1000 - 3000mm
Motor capacity (KW) | Traveling height (ladder width) 1000 | Traveling height (ladder width) 800 | Traveling height (ladder width) 600 | |||
1000-3000 | 5.5 | 1000-3500 | 5.5 | 1000-3700 | 5.5 | |
3400-4500 | 7.5 | 3600-4700 | 7.5 | 3800-4900 | 7.5 | |
4600-4900 | B | 4800-5100 | B | 5000-5200 | B | |
5000-5900 | 11 | 5200-5900 | 11 | 5300-5900 | 11 | |
1000 | 1000 | 1158 | 1238 | 1600 | 1660 | 2310 |
800 | 800 | 958 | 1038 | 1400 | 1460 | 2110 |
600 | 600 | 758 | 838 | 1200 | 1260 | 1910 |
Step width | A | B | C | D | E | F |
Model | Traveling height (mm) | Net weight KN | Bearing | Capacity | Transporation dimension | |
R1 KN | R2 KN | h | I | |||
(600)-30 Speed:0.5m/s | 3000 | 67 | 46 | 41 | 2750 | 10900 |
3500 | 60 | 49 | 44 | 2780 | 11890 | |
4000 | 64 | 52 | 47 | 2810 | 12880 | |
4500 | 68 | 56 | 50 | 2830 | 13870 | |
5000 | 71 | 59 | 53 | 2840 | 14660 | |
5500 | 75 | 62 | 56 | 2860 | 15860 | |
6000 | 79 | 65 | 59 | 2870 | 16860 | |
(800)-30 Speed:0.5m/s | 3000 | 69 | 52 | 47 | 2750 | 10900 |
3500 | 63 | 56 | 50 | 2780 | 11890 | |
4000 | 67 | 60 | 54 | 2810 | 12880 | |
4500 | 71 | 64 | 57 | 2830 | 13870 | |
5500 | 74 | 68 | 60 | 2840 | 14860 | |
5500 | 82 | 74 | 66 | 2860 | 15860 | |
6000 | 86 | 78 | 69 | 2870 | 16860 | |
(1000)-30 Speed:0.5m/s | 3000 | 63 | 59 | 53 | 2750 | 10900 |
3500 | 67 | 64 | 57 | 2780 | 11890 | |
4000 | 71 | 68 | 61 | 2810 | 12890 | |
4500 | 75 | 73 | 65 | 2830 | 13870 | |
5000 | 83 | 79 | 71 | 2840 | 14860 | |
5500 | 87 | 84 | 75 | 2860 | 15860 | |
6000 | 92 | 88 | 79 | 2870 | 16660 |
Instruction
1.When the escalator to be installed above the second floor. Don't have a pit.. Layout drawing must be
matched between up and down
2.Keep the sufficient space at both EXIT and EXTRANCE of escalator. The width must be less than
1238. The depth from handrail bell revered end to the front obstacle must be not less than 2500.
3.Space between handrail belt of escalator and obstacle must be not less than 500.
4.Motor AC 380 V 50 HZ. See in the table.
5.By the user to provide a grounding resistance of less than 4 ohms.
6.Provide by user to the main switch of the power requirements of 3phases 5 wires.
7. All the dimensions are measured by MM.
30° Escalator construction layout drawing
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1992
Total Annual:
3,000,000-5,000,000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
We offer 3 year quality guarantee for all products. Our main products are: Elevator Buttons, Elevator Light Curtain, Photoelectric Switch, Elevator Display, COP & LOP, Traction Machine, Door Mechanism. And we provide best prices on: Guide Rail, Guide Shoe, Co... We offer 3 year quality guarantee for all products. Our main products are: Elevator Buttons, Elevator Light Curtain, Photoelectric Switch, Elevator Display, COP & LOP, Traction Machine, Door Mechanism. And we provide best prices on: Guide Rail, Guide Shoe, Co...
Get in touch with us
Leave a Message, we will call you back quickly!