China Customized Ttlr4 Mouse Elisa Kit 96 Wells High Sensitive With 2 Hours Assay Time
China Customized Ttlr4 Mouse Elisa Kit 96 Wells High Sensitive With 2 Hours Assay Time

  1. China Customized Ttlr4 Mouse Elisa Kit 96 Wells High Sensitive With 2 Hours Assay Time

Customized Ttlr4 Mouse Elisa Kit 96 Wells High Sensitive With 2 Hours Assay Time

  1. MOQ: Negotiation
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms Western Union, T/T
Supply Ability In Stock
Delivery Time 1-3 business days, bulk order within one week
Packaging Details Wrapped with ice pack and styrofoam package
Assay Principle Sandwich
Customized Acceptable
Delivery Within 48 hours
Known as TTLR4
Quality CE, ISO
Assay Time 2 hours
Brand Name BT Lab
Model Number Cat.No E1663Mo
Certification CE, ISO9001:2005, MSDS
Place of Origin Shanghai, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms Western Union, T/T Supply Ability In Stock
Delivery Time 1-3 business days, bulk order within one week Packaging Details Wrapped with ice pack and styrofoam package
Assay Principle Sandwich Customized Acceptable
Delivery Within 48 hours Known as TTLR4
Quality CE, ISO Assay Time 2 hours
Brand Name BT Lab Model Number Cat.No E1663Mo
Certification CE, ISO9001:2005, MSDS Place of Origin Shanghai, China
High Light rat elisa kitsandwich elisa kit

High Mouse Specificity and Sensitivity TTLR4 ELISA Kit 96 Wells Customized

 

Cat.No E1663Mo

Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.

 

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.

Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.

CV(%) = SD/mean x 100

Intra-Assay: CV<8%

Inter-Assay: CV<10%

 

Reagent Provided

Components Quantity
Standard Solution (24ng/ml) 0.5ml x1
Pre-coated ELISA Plate 12 * 8 well strips x1
Standard Diluent 3ml x1
Streptavidin-HRP 6ml x1
Stop Solution 6ml x1
Substrate Solution A 6ml x1
Substrate Solution B 6ml x1
Wash Buffer Concentrate (30x) 20ml x1
Biotinylated Mouse TLR-4 Antibody 1ml x1
User Instruction 1
Plate Sealer 2 pics
Zipper bag 1 pic

 

Material Required But Not Supplied

  • 37°C±0.5°C incubator
  • Absorbent paper
  • Precision pipettes and disposable pipette tips
  • Clean tubes
  • Deionized or distilled water
  • Microplate reader with 450 ± 10nm wavelength filter

 

Precautions

  • Prior to use, the kit and sample should be warmed naturally to room temperature 30 minutes.
  • This instruction must be strictly followed in the experiment.
  • Once the desired number of strips has been removed, immediately reseal the bag to protect the remain from deterioration. Cover all reagents when not in use.
  • Make sure pipetting order and rate of addition from well-to-well when pipetting reagents.
  • Pipette tips and plate sealer in hand should be clean and disposable to avoid cross-contamination.
  • Avoid using the reagents from different batches together.
  • Substrate solution B is sensitive to light, don’t expose substrate solution B to light for a long time.
  • Stop solution contains acid. Please wear eye, hand and skin protection when using this material. Avoid contact of skin or mucous membranes with kit reagent.
  • The kit should not be used beyond the expiration date.

 

Assay Procedure

1. Prepare all reagents, standard solutions and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature.

2. Determine the number of strips required for the assay. Insert the strips in the frames for use. The unused strips should be stored at 2-8°C.

3. Add 50μl standard to standard well. Note: Don’t add antibody to standard well because the standard solution contains biotinylated antibody.

4. Add 40μl sample to sample wells and then add 10μl anti-TLR-4 antibody to sample wells, then add 50μl streptavidin-HRP to sample wells and standard wells ( Not blank control well ). Mix well. Cover the plate with a sealer. Incubate 60 minutes at 37°C.

5. Remove the sealer and wash the plate 5 times with wash buffer. Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1 minute for each wash. For automated washing, aspirate all wells and wash 5 times with wash buffer, overfilling wells with wash buffer. Blot the plate onto paper towels or other absorbent material.

6. Add 50μl substrate solution A to each well and then add 50μl substrate solution B to each well. Incubate plate covered with a new sealer for 10 minutes at 37°C in the dark.

7. Add 50μl Stop Solution to each well, the blue color will change into yellow immediately.

8. Determine the optical density (OD value) of each well immediately using a microplate reader set to 450 nm within 10 minuets after adding the stop solution.

 

Summary

1. Prepare all reagents, samples and standards.

2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.

3. Wash the plate 5 times.

4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.

5. Add stop solution and color develops.

6. Read the OD value within 10 minutes.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Seller

  • Year Established:

    2010

  • Ecer Certification:

    Active Member

Shanghai Korain Biotech Co. was built in 2010. As an creator in reagents and tools for life science, Korainbio provide researchers with tools and scientific support including 30,000 antibodies, 1000+ proteins and 5000 ELISA kits. We aim to be a leading provider with world-class level for the researc... Shanghai Korain Biotech Co. was built in 2010. As an creator in reagents and tools for life science, Korainbio provide researchers with tools and scientific support including 30,000 antibodies, 1000+ proteins and 5000 ELISA kits. We aim to be a leading provider with world-class level for the researc...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai Korain Biotech Co., Ltd
  • #1008.Junjiang Internatioanl Bldg. 228 Ningguo Rd. Yangpu Dist. Shanghai. 200090. China
  • https://www.elisatest-kit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement