Payment Terms | Western Union, T/T |
Supply Ability | In Stock |
Delivery Time | 1-3 business days, bulk order within one week |
Packaging Details | Wrapped with ice pack and styrofoam package |
Assay Principle | Sandwich |
Customized | Acceptable |
Delivery | Within 48 hours |
Known as | TTLR4 |
Quality | CE, ISO |
Assay Time | 2 hours |
Brand Name | BT Lab |
Model Number | Cat.No E1663Mo |
Certification | CE, ISO9001:2005, MSDS |
Place of Origin | Shanghai, China |
View Detail Information
Explore similar products
Sandwich Type Mouse Interferon Gamma ELISA Kit With 2 Hours Assay Time
96 Wells Mouse High Specificity and Sensitivity IFNG ELISA Kit 48 Wells For
ISO Certificate Mouse ELISA Kit 96 Wells Custom Available With Serum Sample
High Sensitive Sandwich Vegf Elisa Kit 2.48ng / L Sensitivity 96 Wells
Product Specification
Payment Terms | Western Union, T/T | Supply Ability | In Stock |
Delivery Time | 1-3 business days, bulk order within one week | Packaging Details | Wrapped with ice pack and styrofoam package |
Assay Principle | Sandwich | Customized | Acceptable |
Delivery | Within 48 hours | Known as | TTLR4 |
Quality | CE, ISO | Assay Time | 2 hours |
Brand Name | BT Lab | Model Number | Cat.No E1663Mo |
Certification | CE, ISO9001:2005, MSDS | Place of Origin | Shanghai, China |
High Light | rat elisa kit ,sandwich elisa kit |
High Mouse Specificity and Sensitivity TTLR4 ELISA Kit 96 Wells Customized
Cat.No E1663Mo
Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.
*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.
CV(%) = SD/mean x 100
Intra-Assay: CV<8%
Inter-Assay: CV<10%
Reagent Provided
Components | Quantity |
Standard Solution (24ng/ml) | 0.5ml x1 |
Pre-coated ELISA Plate | 12 * 8 well strips x1 |
Standard Diluent | 3ml x1 |
Streptavidin-HRP | 6ml x1 |
Stop Solution | 6ml x1 |
Substrate Solution A | 6ml x1 |
Substrate Solution B | 6ml x1 |
Wash Buffer Concentrate (30x) | 20ml x1 |
Biotinylated Mouse TLR-4 Antibody | 1ml x1 |
User Instruction | 1 |
Plate Sealer | 2 pics |
Zipper bag | 1 pic |
Material Required But Not Supplied
Precautions
Assay Procedure
1. Prepare all reagents, standard solutions and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature.
2. Determine the number of strips required for the assay. Insert the strips in the frames for use. The unused strips should be stored at 2-8°C.
3. Add 50μl standard to standard well. Note: Don’t add antibody to standard well because the standard solution contains biotinylated antibody.
4. Add 40μl sample to sample wells and then add 10μl anti-TLR-4 antibody to sample wells, then add 50μl streptavidin-HRP to sample wells and standard wells ( Not blank control well ). Mix well. Cover the plate with a sealer. Incubate 60 minutes at 37°C.
5. Remove the sealer and wash the plate 5 times with wash buffer. Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1 minute for each wash. For automated washing, aspirate all wells and wash 5 times with wash buffer, overfilling wells with wash buffer. Blot the plate onto paper towels or other absorbent material.
6. Add 50μl substrate solution A to each well and then add 50μl substrate solution B to each well. Incubate plate covered with a new sealer for 10 minutes at 37°C in the dark.
7. Add 50μl Stop Solution to each well, the blue color will change into yellow immediately.
8. Determine the optical density (OD value) of each well immediately using a microplate reader set to 450 nm within 10 minuets after adding the stop solution.
Summary
1. Prepare all reagents, samples and standards.
2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.
3. Wash the plate 5 times.
4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.
5. Add stop solution and color develops.
6. Read the OD value within 10 minutes.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2010
Ecer Certification:
Active Member
Shanghai Korain Biotech Co. was built in 2010. As an creator in reagents and tools for life science, Korainbio provide researchers with tools and scientific support including 30,000 antibodies, 1000+ proteins and 5000 ELISA kits. We aim to be a leading provider with world-class level for the researc... Shanghai Korain Biotech Co. was built in 2010. As an creator in reagents and tools for life science, Korainbio provide researchers with tools and scientific support including 30,000 antibodies, 1000+ proteins and 5000 ELISA kits. We aim to be a leading provider with world-class level for the researc...
Get in touch with us
Leave a Message, we will call you back quickly!