China factories

China factory - Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co. , Limited

  • China,Guangzhou ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China UL 1642 Temperature Controlled Type External Short Circuit Tester 500A
China UL 1642 Temperature Controlled Type External Short Circuit Tester 500A

  1. China UL 1642 Temperature Controlled Type External Short Circuit Tester 500A
  2. China UL 1642 Temperature Controlled Type External Short Circuit Tester 500A
  3. China UL 1642 Temperature Controlled Type External Short Circuit Tester 500A
  4. China UL 1642 Temperature Controlled Type External Short Circuit Tester 500A

UL 1642 Temperature Controlled Type External Short Circuit Tester 500A

  1. MOQ: 1
  2. Price: Customized
  3. Get Latest Price
Payment Terms T/T
Supply Ability 1 sets/month
Delivery Time 30 days
Packaging Details Plywood Case
Max. load current 500A
DC response time ≤5μs
Built-in resistor 9±1mΩ
Control method PLC and Touch screen
Inner chamber size W500*500H*D500mm
Inner chamber material Stainless steel
Voltage collection range 0~10V
Voltage acquisition rate 1 time/S
Brand Name Sinuo
Model Number SN551-125L500A
Certification Calibration Certificate (Cost Additional)
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 1 sets/month
Delivery Time 30 days Packaging Details Plywood Case
Max. load current 500A DC response time ≤5μs
Built-in resistor 9±1mΩ Control method PLC and Touch screen
Inner chamber size W500*500H*D500mm Inner chamber material Stainless steel
Voltage collection range 0~10V Voltage acquisition rate 1 time/S
Brand Name Sinuo Model Number SN551-125L500A
Certification Calibration Certificate (Cost Additional) Place of Origin China
 

UL 1642 Temperature Controlled Type External Short Circuit Tester 500A

 

Complied Standards & Clauses


 

It is conforms to the standard of IEC 60335-1:2021 Annex B, UN38.3 clause 4.5 Test T.5, UL 1642, IEC 62619:2017 clause 7.2.1, IEC62133-1:2017 clause 7.3.2 , IEC62133-2:2017 clause 7.3.1 and 7.3.2 , IEC62133:2014 clause 7.3.2,8.3.1, 8.3.2, IEC60086-4 clause 6.5.1, IEC60086-4 clause 6.5.8 6.5.9 , and so on .


Equipment overview


 

Temperature control: 

Normal temperature RT+10℃~100℃ (can be preset)

Temperature rise rate 3℃/min

Temperature dial 0.5℃

Temperature uniformity: ±2℃

Basic performance: 

1: Simple operation and control: touch screen human-machine interface, touch editing control; the battery is placed on the shelf of the thermostat. Close the door and press the touch screen test button to automatically complete the test.

2: Safety and explosion-proof: The inner and outer boxes have been strengthened in design.

3: Overall aesthetic design: beautiful and elegant appearance.

4: Convenient to move into position: The bottom of the equipment is designed with universal wheels and leveling feet to facilitate the movement and fixation of the equipment.


Technical Parameters


 

Model SN551-125L500A
Max. load current 500A
DC response time ≤5μs
Built-in resistor 9±1mΩ
Inner chamber size W500*500H*D500mm
Control method PLC and Touch screen
Inner chamber material Stainless steel
Sealing strip Corrosion-resistant silicone.
Temperature control

Normal temperature RT+10℃~100℃ (can be preset)

Temperature rise rate 3℃/min

Temperature dial 0.5℃

Temperature uniformity: ±2℃

Test stop condition

1) The battery temperature drops to 20% lower than the peak;

2) Short circuit time

Battery surface temperature Can monitor temperature changes during battery surface testing
Sample rack Stainless steel SUS #201 perforated steel plate storage rack, with a maximum load-bearing capacity of 30KG on a single layer. The height is adjustable at the same time.
Hall element collects current signal

Hall elements are used to collect the current generated when the short-circuit system is short-circuited, avoiding the generation of contact resistance, and the data transmission is stable and accurate;

 

Lead hole There is a lead hole with a diameter of 50mm on the left side of the box for test wires to pass through.

 

Chamber door

High-strength hinges are used to fix the door, and at least 2 sets of explosion-proof locks can be installed on the door to fix it.

 

Explosion-proof pressure relief device It has the function of exhaust, explosion-proof and pressure relief. The rear of the protective box has a magnet-adsorbed pressure relief door (200*200mm). When strong airflow impacts, the pressure relief door automatically opens and closes to reduce the impact of the explosion.

 

 

 

 

Lighting The test chamber door is designed with high-brightness LED lighting to make it easy to see the test conditions in the test chamber.
 

Details


 

 
 
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2019

  • Employee Number:

    <100

  • Ecer Certification:

    Verified Supplier

    Sinuo Testing Equipment Co., Limited established in 2019, but Sinuo has rich experience in manufacturing test euipment, test system and offering overall laboratory construction of electronic and electrical products. Sinuo's main products include electrical vehicle te...     Sinuo Testing Equipment Co., Limited established in 2019, but Sinuo has rich experience in manufacturing test euipment, test system and offering overall laboratory construction of electronic and electrical products. Sinuo's main products include electrical vehicle te...

+ Read More

Get in touch with us

  • Reach Us
  • Sinuo Testing Equipment Co. , Limited
  • Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone, Shibi Street, Panyu District, Guangzhou, China
  • https://www.evtestequipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement