China 800V DC Surge Protector 2P Replace Type DIN 43880 40kA
China 800V DC Surge Protector 2P Replace Type DIN 43880 40kA

  1. China 800V DC Surge Protector 2P Replace Type DIN 43880 40kA
  2. China 800V DC Surge Protector 2P Replace Type DIN 43880 40kA

800V DC Surge Protector 2P Replace Type DIN 43880 40kA

  1. MOQ:
  2. Price:
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, Western Union, MoneyGram
Delivery Time 15work days
Code FSP-D40
Pole 2P/3P
In(8/20)us(KA) 20KA
Imax(8/20)us(KA) 40KA
Standard IEC/EN61643
Type II
Characteristic Curve B,C,D
Protection Degree IP20
Electrical life More than 8000times
Mechanical life More than 2000times
Capacity 3 Modules, DIN 43880
Product Warranty TWO YEARS
Brand Name FEEO
Model Number dc spd
Certification CE TUV
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, Western Union, MoneyGram Delivery Time 15work days
Code FSP-D40 Pole 2P/3P
In(8/20)us(KA) 20KA Imax(8/20)us(KA) 40KA
Standard IEC/EN61643 Type II
Characteristic Curve B,C,D Protection Degree IP20
Electrical life More than 8000times Mechanical life More than 2000times
Capacity 3 Modules, DIN 43880 Product Warranty TWO YEARS
Brand Name FEEO Model Number dc spd
Certification CE TUV Place of Origin CHINA
High Light DC Surge Protector 2P800V DC Surge ProtectorDIN 43880 DC Surge Protector
Model FSP-D40  
UC (V DC) 600/800V  
Max System Discharge Current (8/20 μs) [Imax] 40kA  
Voltage Protection Level [UP] ≤2.5kV  
Integrated Fuse Breaking Capacity/Interrupting Rating 40kA/600Vdc  
Technology Short-Circuit Interruption (SCI) Overcurrent Protection  
Operating Temperature Range [TU] -40°C to +80°C  
Nominal Discharge Current (8/20 μs) [(DC+/DC-) --> PE] [n] 20kA  
Response Time [tA] <25ns
Operating State/Fault Indication Green (good)/Red (replace)    
Conductor Ratings and Cross-Sectional Area Min
Mounting Max 60/75°C 1.5mm2/14AWG Solid/Flexible    
35mm DIN Rail per EN 60715 60/75°C 35mm/2AWG Stranded/25mm2/4AWG Flexible
Enclosure Material UL 94V0 Thermoplastic    
Degree of Protection IP20
Capacity 3 Modules, DIN 43880    
Standards Information IEC 61643-31 Type 2, IEC 61643-1 Class II
Product Warranty Two Years**    
       

 

1) Selection of voltage protection level (UP)

The value of UP should not exceed the rated value of the impulse withstand voltage of the protected equipment, and UP requires that the insulation of the SPD and the protected equipment should be well matched.

In the low-voltage power supply and distribution system, the equipment should have a certain ability to withstand surges, that is, the ability to withstand impulse overvoltage. When the impulse overvoltage withstand voltage of various equipment of 220/380V three-phase system cannot be obtained, it can be selected according to the given index of IEC 60664-1 and GB 50057-1994 (2000 edition).

2) Selection of nominal discharge current In (impact current capacity)

The peak current of the 8/20 μs current wave that flows through the SPD. It is used for class II classification test for SPD, and also used for pretreatment of class I and class II classification test for SPD.

In fact, In is the maximum peak value of the inrush current that the SPD can pass the specified number of times (generally 20 times) and the specified waveform (8/20 μs) without substantial damage.

3) Selection of the maximum discharge current Imax (limit impact current capacity)

The peak current flowing through SPD, 8/20 μs current wave, used for class II classification test. There are many similarities between Imax and In. They both use the peak current of 8/20 μs current wave to do Class II classification test on SPD. The difference is also obvious. Imax only does one impact test on SPD, and SPD does not undergo substantial damage after the test; while In can do 20 such tests, SPD cannot have substantial damage after the test. Therefore, Imax is the current limit value of the impact, so the maximum discharge current is also called the limit impact current capacity. Obviously, Imax>In.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company,Seller

  • Year Established:

    2010

  • Total Annual:

    3000000-3200000

  • Employee Number:

    50~100

  • Ecer Certification:

    Active Member

YUEQING FEEO ELECTRIC CO.,LTD is a professional solar PV electric components manufacturer located in Yueqing City, China. We're specialized in DC circuit breakers, Surge Protective Devices, PV fuses, isolator switches, MC4 connectors etc.With CE, RoHS, CB, TUV certificates and authorized dealers... YUEQING FEEO ELECTRIC CO.,LTD is a professional solar PV electric components manufacturer located in Yueqing City, China. We're specialized in DC circuit breakers, Surge Protective Devices, PV fuses, isolator switches, MC4 connectors etc.With CE, RoHS, CB, TUV certificates and authorized dealers...

+ Read More

Get in touch with us

  • Reach Us
  • YUEQING FEEO ELECTRIC CO.,LTD
  • Keaisi Road, Xiangyang Industrial zone , Yueqing, Zhejiang,China.
  • https://www.feeomcb.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement