China Water Chlorine Sensor
China Water Chlorine Sensor

  1. China Water Chlorine Sensor
  2. China Water Chlorine Sensor

Water Chlorine Sensor

  1. MOQ:
  2. Price: $500.00 - $700.00/pieces
  3. Get Latest Price
Product name Residual chlorine sensor
Principle the constant voltage method
Range 0~2.000mg/L(HClO)
Accurate ±5% or ±0.05mg/L
Resolution 0.001mg/L
Working temperature 0 ~ 50℃
Power Supply 12~24VDC±10%
Protection IP68
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Port Xi'an or other
Supply Ability 500 Piece/Pieces per Month

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Product name Residual chlorine sensor Principle the constant voltage method
Range 0~2.000mg/L(HClO) Accurate ±5% or ±0.05mg/L
Resolution 0.001mg/L Working temperature 0 ~ 50℃
Power Supply 12~24VDC±10% Protection IP68
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available Port Xi'an or other
Supply Ability 500 Piece/Pieces per Month

Water Chlorine Sensor  

1. Applications 

Kacise on-line residual chlorine sensor is used to monitor the residual chlorine content continuously in drinking water treatment plant, canning plant, drinking water distribution network, swimming pool, cooling circulating water, water quality treatment project.

 

2.Technical Specifications

Module No.

KWS-3000

Principle

the constant voltage method

Range

0~2.000mg/L(HClO)

Accurate

±5% or ±0.05mg/L

Resolution

0.001mg/L

Calibration Function

Two point Calibration (Zero and Slope )

Temperature Compensation

Temperature compensation automatically (Digit temperature sensor)

Working temperature

0 ~ 50℃

Output

Support RS-485, MODBUS protocol

Power Supply

12~24VDC±10%

Velocity

30-60 L/h

Installation

Circulation pool installation

size

30×233mm(Φ×L)

Protection

IP68

Material

Polyacetal resin, PTFE, Gold, Silver

Polyformaldehyde resin, teflon, gold, silver, electro conductive rubber

 

 

3 Outline

 

 

4 Electric Connect

The electrode should be installed closely with the circulation pool.  The electrode measurement part should be placed in the area near the circulation pool inlet. It is not allowed to face the outlet. Ensure the smooth flow . We suggest to control the flow rate within 30-60l /h to ensure the test accuracy.

Red:  Power supply (12~24V)              

Black:  Ground(GND)

Blue:  485A

White:  485B

Exposed wire:  shielded wire

Please make sure that you connect the wire correctly.

Cable specifications: the cable has a certain corrosion resistance, considering that it has been immersed in water (including seawater) or exposed to air for a long time. The diameter is Φ6 mm. Please make the  waterproof processing on cable joint.

 

5 Maintenance

1) Sensor detection and maintenance

The new electrode and the electrode placed for a long time should be activated before use. The sensor shall be left in the tap water for 24 hours.If the returned value is not correct, please make the following operation.

  • Calibration of zero point and slope of electrode
  • Returned to the factory for inspection.

2) Calibration of sensors

a)  zero point calibration: the sensor probe is placed in chlorine-free water for zero point calibration after the numerical stability.

b) slope calibration: the sensor probe is placed in the flow pool with residual chlorine standard liquid, and the slope calibration is performed after the value is stable.  Suggest to use 1-2mg/L HCIO standard solution. About the preparation and determination of the standard liquid, we can refer to the  determination of residual chlorine standard.

Note: the sensor has been calibrated before delivery. Since the preparation of its standard liquid has high requirements on personnel, non-professionals may not be qualified for this job. Only if the value is determined to be inaccurate, it is recommended that the user do not calibrate the sensor.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement