Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 100 |
Delivery Time | 3-10days |
Packaging Details | Common package or custom package |
Measurement mode | Immersion measurement |
Measuring range | No 3-n: (0.1-1) mg/l, (1-10) mg/l, (10-100) mg/l, (100-1000) mg/L Cl-: (1 ~ 1000) mg/L PH: 0 ~ 14 Temperature: (0 ~60) °C |
Accuracy | ≤ ± 3% |
Repeatability | ≤2% |
Method of measurement | Ion selective electrode method |
Resolution | No3-n (minimum range) :0.01 mg/L Cl-: 0.1 mg/L Ph: 0.01 |
Measurement parameter | NO3-N, pH,temperature NO3-N, pH, CL-, temperature |
Model number | KNN300 A KNN300 B |
Brand Name | kacise |
Model Number | KNN300 |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmissi
Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing
Accurate 10% Water Quality Sensor RS485 Output Multi Parameter
Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 100 |
Delivery Time | 3-10days | Packaging Details | Common package or custom package |
Measurement mode | Immersion measurement | Measuring range | No 3-n: (0.1-1) mg/l, (1-10) mg/l, (10-100) mg/l, (100-1000) mg/L Cl-: (1 ~ 1000) mg/L PH: 0 ~ 14 Temperature: (0 ~60) °C |
Accuracy | ≤ ± 3% | Repeatability | ≤2% |
Method of measurement | Ion selective electrode method | Resolution | No3-n (minimum range) :0.01 mg/L Cl-: 0.1 mg/L Ph: 0.01 |
Measurement parameter | NO3-N, pH,temperature NO3-N, pH, CL-, temperature | Model number | KNN300 A KNN300 B |
Brand Name | kacise | Model Number | KNN300 |
Certification | CE | Place of Origin | CHINA |
High Light | IP68 Waterproof Water Quality Sensor ,POM Material Water Quality Sensor |
KNN300 series online nitrate nitrogen Sensor is an online water quality Sensor developed on the basis of digital water quality analysis platform. Integrated design, using industrial on- line ion selective electrode, digital, intelligent sensor design concept. The functions of electrode signal detection, temperature detection, automatic compensation and digital signal conversion are realized in the instrument. RS485 signal output, easy networking and system integration, widely used in surface water, pollution sources and other industries.
Integrated design, anti-electromagnetic interference
Industrial Online ion-selective electrode, can work stably for a long time
Temperature, chloride ion (CL-) and other multi-parameter compensation algorithm to ensure the accuracy of measurement
Built-in Air Purge automatic cleaning system, greatly reducing the maintenance workload
Stainless steel case, IP68 waterproof grade, suitable for various working conditions
RS485 signal output, Standard Modbus protocol, easy integration, networking
Water Quality Sensor Model number | KNN300 A | KNN300 B |
Water Quality Sensor Measurement parameter | NO3-N, pH,temperature | NO3-N, pH, CL-, temperature |
Water Quality Sensor Method of measurement | Ion selective electrode method | |
Water Quality Sensor Measurement mode | Immersion measurement | |
Water Quality Sensor Measuring range | No 3-n: (0.1-1) mg/l, (1-10) mg/l, (10-100) mg/l, (100-1000) mg/L Cl-: (1 ~ 1000) mg/L PH: 0 ~ 14 Temperature: (0 ~60) °C | |
Water Quality Sensor Accuracy | ≤±3% | |
Water Quality Sensor Repeatability | ≤2% | |
Water Quality Sensor Resolution | No3-n (minimum range) :0.01 mg/L Cl-: 0.1 mg/L Ph: 0.01 | |
Water Quality Sensor Detection limit | 0.1 mg/L | |
Water Quality Sensor Response time | ≤60s | |
Water Quality Sensor Zero Drift (24h) | ≤3% F.S. | |
Water Quality Sensor Range Drift (24h) | ≤3% F.S. | |
Water Quality Sensor Calibration | Three months | |
Water Quality Sensor period | ||
Water Quality Sensor Temperature range | (0 ~ 60) °C | |
Water Quality Sensor Protection level | IP68 | |
Water Quality Sensor Cleaning mode | Compressed air bar | |
Water Quality Sensor MTBF | ≥1440h/Time | |
Water Quality Sensor Means of communication |
RS485(Modbus RTU) , maximum baud rate 115200 bps | |
Water Quality Sensor Supply voltage | (12/24) V DC | |
Water Quality Sensor Power consumption | < 0.5W | |
Water Quality Sensor Material Quality | Stainless steel, POM | |
Water Quality Sensor Weight | 1.0 kg | |
Water Quality Sensor Contour dimension | 270 mm × φ60 mm |
Website www.kacise.com
Phone +86-17719566736
Email sales@kacise.com
Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us