Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 100 |
Delivery Time | 10-15 days |
Packaging Details | Common package or custom package |
Measuring range | 0~10.00mg/L(0~100.00mg/L) |
Resolution | 0.1mg/L |
Accuracy | ±10% or ±1mg/L |
Working pressure | <0.1MPa |
Temperature compensation | Temperature compensation (Pt1000) |
Output | Digital Sensor,Support RS-485,MODBUS protocol |
Power supply | 12-24VDC (10-30VDC) |
Output signal | 4~20mA,RS485 optional |
Brand Name | kacise |
Model Number | KAN601 |
Certification | CE,FDA |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmissi
Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing
Accurate 10% Water Quality Sensor RS485 Output Multi Parameter
Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 100 |
Delivery Time | 10-15 days | Packaging Details | Common package or custom package |
Measuring range | 0~10.00mg/L(0~100.00mg/L) | Resolution | 0.1mg/L |
Accuracy | ±10% or ±1mg/L | Working pressure | <0.1MPa |
Temperature compensation | Temperature compensation (Pt1000) | Output | Digital Sensor,Support RS-485,MODBUS protocol |
Power supply | 12-24VDC (10-30VDC) | Output signal | 4~20mA,RS485 optional |
Brand Name | kacise | Model Number | KAN601 |
Certification | CE,FDA | Place of Origin | CHINA |
High Light | RS485 Ammonia Nitrogen Sensor ,3/4 NPT Thread Water Quality Probe ,Ip68 Water Quality Probe |
Ip68 4~20mA RS485 Ammonia Nitrogen Sensor For Water Quality
Kacise KAN601 Online Ammonia Nitrogen Sensor Patented Probe IP68 Protection Level Easy To Install: 3/4 NPT Thread
KAN601 Online Ammonia Nitrogen Sensor
KAN601 integrated online ammonia nitrogen sensor is fabricated using a PVC membrane-based ammonium ion-selective electrode for testing ammonium ion content in water with temperature compensation to ensure fast, simple, accurate, and economical testing. The technical parameters, maintenance, and communication protocols of the ammonia nitrogen sensor are described in detail in this user manual.
Model | KAN601 |
Measuring range | 0~10.00mg/L(0~100.00mg/L) |
Resolution | 0.1mg/L |
Accuracy | ±10% or ±1mg/L |
Working temperature | 0~40℃ |
Working pressure | <0.1MPa |
Medium PH range | 4~10 pH |
Temperature compensation | Temperature compensation (Pt1000) |
Power supply | 12~24 VDC ±10% |
Signal output | RS-485 bus, Modbus/RTU protocol |
Wetted material | PVC and POM |
Installation | 3/4NPT thread, immersion installation |
Cable length | 5 meters, other lengths can be customized |
Calibration | Two-point calibration |
Power consumption | <0.3W@12V |
Protection grade | IP68 |
Dimensional Drawing
Wastewater treatment processes are concerned with controlling the energy-efficient removal of pollutants in the smallest possible space in the shortest possible time.
Required are:
• detailed knowledge of the underlying process
• highest possible transparency of the process steps through corresponding measuring methods
The efficient control of Nitrogen in wastewater systems is possible by making those measurements directly in the wastewater process. This not only ensures purification but above all guarantees the economic operation of the entire plant.
Purification processes for the removal of nitrogen from wastewater
Nitrogen is found in a large variety of compounds and forms and is considered to be the ultimate “quick-change artist”.
In municipal wastewater, it is mainly encountered as a waste product in the form of urea, which is already converted in part to ammonium nitrogen by ammonification.
In the aeration basin, the initial step of nitrification consists of oxidizing the nitrogen present in wastewater via nitrite to nitrate, for which oxygen is required. During subsequent
denitrification, the nitrate (NO3–) is further converted to elemental nitrogen N2 under the absence of oxygen. This nitrogen in gas form is harmlessly released into the environment.
Due to the various framework conditions and different biologically active groups of microorganisms, both methods are conducted in two fundamentally separate processes.
The temporal and spatial sequence can be adapted to local conditions.
Website www.kacise.com
Phone +86-17719566736
Email sales@kacise.com
Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us