China factories

China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Compact Low Power Methane Gas Detector Sensor With 0.2% VOL Detection Limit
China Compact Low Power Methane Gas Detector Sensor With 0.2% VOL Detection Limit

  1. China Compact Low Power Methane Gas Detector Sensor With 0.2% VOL Detection Limit
  2. China Compact Low Power Methane Gas Detector Sensor With 0.2% VOL Detection Limit

Compact Low Power Methane Gas Detector Sensor With 0.2% VOL Detection Limit

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T, Western Union, MoneyGram
Supply Ability 1000 Pieces per Week
Delivery Time 5-8 working days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Operating temperature -40℃~ +70℃
Output mode Standard TTL Serial Port
Operating voltage 3.0VDC ~3.6VDC
Explosion proof sign Ex Ia IICT6 Ga
Product weight 255g
Protection degree IP66
Response time T90<15s
Measurement error @25℃ <+0.06%VOL,0-1%VOL <+6%True Value,1-20% VOL
Brand Name Kacise
Model Number TDLAS103
Place of Origin China (Mainland)
Certification certificate of explosion-proof, CE

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, MoneyGram Supply Ability 1000 Pieces per Week
Delivery Time 5-8 working days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Operating temperature -40℃~ +70℃ Output mode Standard TTL Serial Port
Operating voltage 3.0VDC ~3.6VDC Explosion proof sign Ex Ia IICT6 Ga
Product weight 255g Protection degree IP66
Response time T90<15s Measurement error @25℃ <+0.06%VOL,0-1%VOL <+6%True Value,1-20% VOL
Brand Name Kacise Model Number TDLAS103
Place of Origin China (Mainland) Certification certificate of explosion-proof, CE
High Light 0.2% VOL Methane Gas Detector SensorCompact Methane Gas Detector SensorLow Power Methane Gas Detector Sensor

Introduction

 

The 3.3V methane laser sensor is designed using tunable diode laser absorption spectroscopy (TD-LAS), utilizing a 1653.7nm laser to detect methane via its distinct "fingerprint spectrum" absorption. It's resistant to interference from water vapor or other gases. By combining direct absorption and wavelength modulation technology, and employing an "N" type optical path structure, it achieves a long absorption path, ensuring high sensitivity and precision. The sensor also features a low-temperature laser, a photodetector, and a temperature compensation algorithm, making it adaptable to various environments. Its standardized interface and communication protocol enhance compatibility. This core component of methane detectors is ideal for applications in underground spaces, catering, industrial chemical sectors, and coal mines for gas leak detection and alarms.

 

Feature

High detection accuracy

Direct and wavelength modulation technology combined with folded optical path design, measurement error ≤±6% true value @25℃

Good environmental adaptability

Wide temperature compensation correction algorithm, can meet -40~+70℃ application

Strong anti-interference

Methane "fingerprint spectrum" laser absorption detection technology, anti-poisoning, anti-water vapor and other gas interference;

Strong structural protection

Stainless steel material design, meets the explosion-proof level Exia IIC T6 Ga

Low cost

Long service life, low power consumption, modular design, easy to integrate

 

 

Dimensions

 

Technical Parameters:

Parameters Technical Indicators
Measuring gas Methane
Measuring principle TD-LAS
Detection mode Dispersive
Measuring range 0-20% VOL (customizable)
Measurement error @25℃ <+0.06%VOL,0-1%VOL
<+6%True value,1-20% VOL
Lower detection limit 0.2% VOL
Minimum resolution 0.01% VOL
Response time T90<15s
Operating voltage 3.0VDC ~3.6VDC
Average operating current <30mA
Peak current <210mA
Output mode Standard TTL serial port
Operating temperature -40℃~ +70℃
Operating humidity 0 ~ 99% RH (condensation)
Explosion proof sign Ex ia IICT6 Ga
Intrinsic safety parameter Ui:3.3V Ii:50mA
Pi:0.250W Ci:20uF
Li:3.14uH
Protection degree IP66
Product weight 255g
Products dimensions φ41.7mmx63.6mm
 

Communication Interface and Definition

Interface form: SH1.0mm/4P

Cable length: 200mm

Number Color Interface definition
1 Red VCC
2 Black GND
3 Blue RX
4 Green TX
 

Communication Protocol

(1) Communication interface configuration

UART serial port: Baud rate: 115200, data bits: 8 bits,

Stop bit: 1 bit, parity bit: no check

(2) Description of communication protocol

Byte sequence number Function code Byte number Unit Example
0 Head of frame 1 - A
1-7 Concentration 7 %VOL +000.00
8 Blank space 1 - <SP>
9-13 Ambient temperature 5 +23.7
14 Blank space 1 - <SP>
15-21 Ambient air pressure 7 hPa 1006.22
22 Blank space 1 - <SP>
23-27 Intensity of light 5 - +16.1
28 Blank space 1 - <SP>
29-35 Gain coefficient 7 - B+6.0
36 Blank space 1 - <SP>
37-38 Fault code 2 - 00
39 Blank space 1 - <SP>
40-41 Xor check code 2 - 3D
42 Carriage return character 1 <CR>: <CR>:
43 Line break character 1 <LF> <LF>

After the sensor is powered on, it goes through a period of preprocessing (6-10s) and then begins to periodically (1Hz) output a fixed-length string. The string format is shown in the figure above.

 

Output string parsing (sample):

A 000.00 + 24.0 + 1006.22 + 16.1 + 006.0 B 00 13

A: the frame head;

+000.00: methane concentration value, two decimal places reserved, unit %vol;

+ 24.0: the environment temperature, the unit ℃;

1006.22: the environment pressure, the unit hPa;

16.1: the laser light intensity and effective range 3.6 21.6;

006.0: magnification factor, normal range 1.0-126.0;

00: fault codes

01: abnormal optical signal; 02; Ambient temperature or abnormal pressure; Optical signal is too strong; 04 laser temperature anomaly;

05: light signal is too weak;

13: xor check code

 

Fault Code

Fault code Meaning Fault code Meaning
0 Sensor working properly 3 The laser signal is strong
1 The photodetector signal is abnormal 4 Laser temperature anomaly
2 Temperature and pressure sensor abnormal 5 The laser signal is too weak

 

 

Support and Services

Our Gas Detector Sensor services include expert assistance with troubleshooting and repairs, as well as maintenance, calibration, and testing to ensure precise operation. We provide product manuals and documentation, and offer guidance on selecting and customizing products. We aim to provide top-notch service to ensure your gas detectors operate effectively and reliably.


Packing and Shipping:
Product Packaging:
Gas Detector Sensor unit
User manual
Mounting hardware
Calibration certificate
Shipping Information:
Expected delivery time: 5-8 business days

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement