Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 1000 Piece/Pieces per Week negotiable |
Delivery Time | 5-8 work days |
Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Measuring Range | -1999~9999 |
Accuracy | 0.2% FS ±1 or 0.5% FS ±1 |
Resolution | 1, 0.1, 0.01 or 0.001 |
Temperature Compensation | 0~50 |
Light Column Accuracy | The light column display accuracy is 1% |
Brand Name | KACISE |
Model Number | KDI Series |
Certification | CE |
Place of Origin | china |
View Detail Information
Explore similar products
4 - 20mA Output Fluid Level Meter Hygienic Tuning Fork Densitometer Insulation
High accuracy Submersible Water Liquid Level Sensor Transmitter For power,
High Frequency Radar Fluid Level Meter Hot Water Level Sensor No Pollution
70m Measuring Range Radar Type Level Transmitter 26GHz Frequency High Accuracy
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 1000 Piece/Pieces per Week negotiable |
Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Measuring Range | -1999~9999 | Accuracy | 0.2% FS ±1 or 0.5% FS ±1 |
Resolution | 1, 0.1, 0.01 or 0.001 | Temperature Compensation | 0~50 |
Light Column Accuracy | The light column display accuracy is 1% | Brand Name | KACISE |
Model Number | KDI Series | Certification | CE |
Place of Origin | china | ||
High Light | KDI Series Display Controller |
KDI Series Display Controller with AC/DC Switching Power Supply Option
Introduction
KACISE's KDI Series Display Controller offers an AC/DC switching power supply option. This flexibility allows users to choose the power source that best suits their application environment. Whether in an area with AC power or where DC power is more convenient, the controller can operate smoothly. It helps reduce the need for additional power conversion equipment, and KACISE's attention to detail in providing this option ensures the controller's usability in diverse scenarios.
Features
· New concept of computer digital auto-tuning
· Clear and clear measurement display
·· Support multi-machine network communication, communication protocol can be freely set
· Unique full open user-defined interface
· Set parameter power-off permanent retention and parameter password lock
· Fully digital cold junction compensation
· Multi-size external structure size
· AC and DC switching power supply mode
Parameters
Matching with standard indexing temperature sensor:
Input Signal |
Indexing No. |
Resolution | Sensor | Range |
B | 1 |
Platinum30-platinum6 rhodium
|
400~1800℃ | |
S | 1 | Platinum10-platinum | 0~1600℃ | |
K | 1 | Nickel chromium-nickel silicon | 0~1300℃ | |
E | 1 |
Nickel chromium-constantan
|
0~1000℃ | |
J | 1 |
Iron-constantan
|
0~1200℃ | |
T | 0.1 |
Copper-constantan
|
-199.9~3200℃ | |
Wre | 1 |
Tungsten3-tungsten25
|
0~2300℃ | |
Pt100 | 1 | Platinum thermal resistance R0 = 100Ω | -199~650℃ | |
Pt100 | 0.1 | Platinum thermal resistance R0= 100Ω | -199.9~320.0℃ | |
Cu50 | 0.1 | Copper thermal resistance R0= 50Ω | -50.0~150.0℃ |
With standard signal transmitter:
Input Signal |
Standard Signal Range |
Input Resistance | Matching Transmitter | Measuring Range |
various mV signal 0~10mA 4~20mA 0~5V 1~5V 30~350Ω |
≥10MΩ ≤250Ω ≤250Ω ≥250KΩ ≥250KΩ |
hall transmitter compatible with DDZ-II type instrument compatible with DDZ-III type instrument compatible with DDZ-II type instrument compatible with DDZ-III type instrument compatible with remote pressure resistors |
set according to user needs.
range: -1999~9999 |
Main Technical parameters
Input Signal | Analog |
Resistance: standard thermal resistance (remote pressure resistance such as Pt100, Cu50)
Galvanic couples: standard thermocouples ( B, S, K, E, J, T, WRe, etc.)
Current: 0~10mA, 4~20mA, 0~20mA, etc. (Input impedance ≤250Ω) |
Measuring Range | -1999~9999 | |
Accuracy | 0.2% FS ±1 or 0.5% FS ±1 | |
Resolution | 1, 0.1, 0.01 or 0.001 | |
Temperature Compensation | 0~50 | |
Display Method |
-19999~9999 measured value display -19999~9999 set value display 0~100% measured value light column display LED operating status display |
|
Light Column Accuracy | The light column display accuracy is 1% | |
Control Method | Position ON / OFF with backlash | |
Output Signal |
Analog output
|
DC 0-5V (load capacity ≤250Ω) DC 1~5V (load capacity ≤250Ω) DC 0~10mA (load capacity ≤750Ω) DC 4~20mA (load capacity ≤500Ω) |
Switch output
|
Relay control output - Relay ON/OFF with backlash Contact capacity: AC220V/3A; DC24V/6A (resistive load)
Controllable silicon output-SCR (controllable zero-crossing pulse), can trigger controllable silicon: 400V/100A
Solid state relay output - SSR (solid state relay control signal) output, 6 ~ 24 / 30mA (voltage cannot be adjusted) |
|
Communication output
|
Interface mode - Standard serial two-way communication interface: RS-485, RS-232C, RS-422, etc. | |
Feed output | DC24V, load capacity ≤30mA | |
control method |
Optional 1~4 limit control, LED indication. The control mode is the relay ON/OFF with backlash (user can set it freely)
|
|
control accuracy | ±1 | |
Alarm mode | You can select 1~4 limit alarm, LED indication. The control mode is the relay ON/OFF with backlash (user can set it freely) | |
Alarm accuracy | ±1 | |
Temperature compensation | 0~5 0°C digital temperature automatic compensation | |
Parameter setting |
• Panel touch type press key digital setting • Parameter setting value is permanently hold when power off • Parameter setting value Password Lock |
|
Protection method |
• Input loop disconnection alarm (when thermocouple or resistance input), relay output, LED indication • Input over/under range alarm • Power under voltage automatic reset •Work abnormally automatic reset (watch dog) |
|
Online communication | The communication protocol is a two-wire system, a three-wire system or a four-wire system (e.g. RS485, RS232C, RS422, etc. ) can also be specially requested by the user. The baud rate of 300 to 9 6 0 0 b p s can be set freely by the internal parameters of the instrument. The interface and the main unit are separated by photo-electricity, and the communication distance can reach 1.2 km. The system adopts the master-slave communication mode. The whole control loop only needs one two (three, four) core cable, which can realize communication with the host computer. The upper computer can call the device number set by the user, and call the scene of each instrument at any time. Data, and can be used to set internal parameters of the instrument. Equipped with data collector and industrial control software, it can realize online communication between multiple instruments and one or more microcomputers. | |
Use environment |
• Ambient temperature 0~5 0°C • Relative humidity ≤ 85 R H • Avoid strong corrosive gases |
|
Power Supply |
Normal type : • A C 220 V + 10 - 1 5 % (50 Hz ± 2Hz linear power source ) Special type: • A C 90 ~ 260 V- - switch power • D C 24 V ±2 V- - switch-off power supply |
|
Power consumption |
• ≤5 W (A C 220 V linear power supply) • ≤4 W (A C 90 V~265 V switch power supply) • ≤4 W (D C 4 V power supply) |
|
Weight | 420g (AC220V linear power supply) |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us