CertifiCAT-partsion | CE |
Supply Ability | 10000 Set / Sets per Month |
Delivery Time | 7-10working days after received deposit |
Packaging Details | Packed in foam firstly,and then reinforced with strong carton box for outer packing |
Display status | working&loading&battery |
Input Voltage | 140-275Vac |
Transfer Time | ≤8ms |
Operating Temperature | 0~40℃ |
Output | 220V ± 10% |
AppliCAT-partsion | MEDICAL/Office/Workshop |
Wave Form | Pure Sine Wave Home UPS |
Power Factor | 100% load ≥ 0.98 |
Brand Name | GSKA |
Model Number | UPS uninterruptible power supply |
Place of Origin | Donggaun,china |
View Detail Information
Explore similar products
LCD Display 10KVA 50Hz Uninterruptible Power Supply
Microprocessor Control Self Diagnostic 700VA 12V 7AH Online UPS
Short Circuit Protection 1000W 50 Hz Uninterruptible Power Supply
Three In One Out 10KVA 15KVA 20KVA LF Online UPS Battery
Product Specification
CertifiCAT-partsion | CE | Supply Ability | 10000 Set / Sets per Month |
Delivery Time | 7-10working days after received deposit | Packaging Details | Packed in foam firstly,and then reinforced with strong carton box for outer packing |
Display status | working&loading&battery | Input Voltage | 140-275Vac |
Transfer Time | ≤8ms | Operating Temperature | 0~40℃ |
Output | 220V ± 10% | AppliCAT-partsion | MEDICAL/Office/Workshop |
Wave Form | Pure Sine Wave Home UPS | Power Factor | 100% load ≥ 0.98 |
Brand Name | GSKA | Model Number | UPS uninterruptible power supply |
Place of Origin | Donggaun,china | ||
High Light | Pure Sine Wave UPS Inverter ,275Vac UPS Inverter |
Pure Sine Wave UPS Inverter Direct Flow AC Power Inductor Device
Functional effect:
With the increasing demand of computer appliCAT-parts-partsion system for power supply, UPS has been paid more and more attention, and gradually developed into a power protection system with voltage stability, frequency stability, filtering, anti-electromagnetic and radio frequency interference, anti-voltage surfing and other functions. Especially in the grid line and power supply quality is not too high, anti-interference technology is backward, and the computer system on the power supply requirements are relatively high, the role of UPS is more obvious.
The protection function of UPS is first shown in the voltage regulation of the mains power supply. The input voltage range of UPS is relatively wide, generally from 170V to 250V, and the quality of the output power supply is quite high. The backup UPS output voltage is 5%~8%, and the output frequency is stable at 1Hz. As shown in Figure 1, the output voltage of the online UPS is stable within 3%, and the output frequency is stable at 0.5Hz. When the mains is normal, UPS power is equivalent to AC mains voltage regulator; At the same time, the battery is charged by the mains, which is also equivalent to the charger. In the case of a sudden mains failure, the UPS automatically switches to the battery power supply to keep the computer running properly and protect software and hardware from damage.
Model | GSKA-500 | GSKA-800 | GSKA-1000 | GSKA-1500 | GSKA-2000 | GSKA-2500 | GSKA-3000 | GSKA-5000 | |
Rated Capacity | 500VA | 800VA | 1000VA | 1500VA | 2000VA | 2500VA | 3000VA | 5000VA | |
Rated Power | 300W | 500W | 700W | 1050W | 1400W | 1800W | 2100W | 3500W | |
Transformer | Toroidal transformer | ||||||||
Interface | LED graphic | ||||||||
Display status | working&loading&battery | ||||||||
Working mode | PV(Photovoltaic priority)/AC(AC priority) optional | ||||||||
Input | Voltage | 140-275Vac | |||||||
Frequency | 45-65Hz | ||||||||
Output | Voltage | 220Vac±3% for inveter; 195v-240V for avr | |||||||
Frequency | 50/60Hz ± 0.3Hz, subject to the main | ||||||||
Wave Form | Pure sine wave | ||||||||
Wave Distortion | ≤3% | ||||||||
Protection | overload/high temperature/output high voltage /output low voltage/ battery low voltage shortcircuit/over-charge/over-discharge/reversed polarity(optional) | ||||||||
Transfer Time | ≤4ms | ||||||||
Battery Voltage | 12VDC | 24VDC | 48VDC | ||||||
Charge Voltage | 13.6V±0.3V | 27.2V±0.6V | 54.5V±1V | ||||||
Low Battery Voltage Limit | 10.9V±0.3V | 21.8V±0.5V | 42V±1V | ||||||
Protections Battery Low Voltage Protection Point | 10.2V±0.3V | 20.5V+0.5V | 41V±1V | ||||||
Charge Current | Max.10A/15A/20A optional | ||||||||
Environmental | Operating Temperature | 0~40℃ | |||||||
Relative Humidity | 10%~90%RH,non-condensing | ||||||||
Storage Temperature | -15-45℃ | ||||||||
Packing | Machine Size(mm) | 280x144x213 | 385x190x320 | ||||||
Qty/Ctn | 4 | 4 | 2 | 2 | 1 | 1 | 1 | 1 | |
Carton Size(mm) | 785x305x240 | 415x410x245 | 410x290x320 | ||||||
CartonG.W.(kg) | 22 | 26 | 17.2 | 19.1 | 410x290x321 |
Company Details
Business Type:
Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company
Year Established:
1985
Total Annual:
4Million-5Million
Employee Number:
50~100
Ecer Certification:
Active Member
Since establishment in 1985, Guangdong ALI Testing Equipment Co., Ltd, a wholly-owned subsidiary of GSKA Group has been providing a wide and complete range of products and services to the society. GSKA has now 16 offices, warehouses and service centres in China, with head office loCAT-part... Since establishment in 1985, Guangdong ALI Testing Equipment Co., Ltd, a wholly-owned subsidiary of GSKA Group has been providing a wide and complete range of products and services to the society. GSKA has now 16 offices, warehouses and service centres in China, with head office loCAT-part...