CertifiCAT-partsion | CE,GS,EPA,CARB,CSA |
Payment Terms | L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal |
Supply Ability | 500 pieces per Month |
Delivery Time | one weeks on receipt of official sales contract |
Packaging Details | Standard plywood and wood package.the actual package size against goods size and handle requires. Si |
Port: | HongKong or ShenZhen,ShangHai,Dalian as required |
Excitation Mode | AC Rotating Exciter |
SpecifiCAT-partsion | Packing Dimension(mm): 741x537x685 |
Alternator | Brushless Self-excited |
Controller | SmartGen, Deepsea, etc |
Cooling method | Automatic Transfer Switch |
Phase | 1 Phase/3 Phase |
Noise | 75dB |
Brand Name | GSKA |
Model Number | BC8500/BC8500T, BC10000/BC10000T,BC12000/BC12000T |
Place of Origin | China OEM |
View Detail Information
Explore similar products
Silent Small Diesel Generator
Water Pump Small Diesel Generator 2.8KW / 4KW / 6.5KW
Silent Portable Small Diesel Generator , 4 Stroke Generator
Open Frame Air Cooled Small Diesel Generator Silent KM290FT
Product Specification
CertifiCAT-partsion | CE,GS,EPA,CARB,CSA | Payment Terms | L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal |
Supply Ability | 500 pieces per Month | Delivery Time | one weeks on receipt of official sales contract |
Packaging Details | Standard plywood and wood package.the actual package size against goods size and handle requires. Si | Port: | HongKong or ShenZhen,ShangHai,Dalian as required |
Excitation Mode | AC Rotating Exciter | SpecifiCAT-partsion | Packing Dimension(mm): 741x537x685 |
Alternator | Brushless Self-excited | Controller | SmartGen, Deepsea, etc |
Cooling method | Automatic Transfer Switch | Phase | 1 Phase/3 Phase |
Noise | 75dB | Brand Name | GSKA |
Model Number | BC8500/BC8500T, BC10000/BC10000T,BC12000/BC12000T | Place of Origin | China OEM |
High Light | Electric Start Small Diesel Generator ,AC Rotating Exciter Diesel Generator |
Convenient Small Diesel Generator Super Quiet Electric Start OEM
The crankshaft of the diesel engine rotates the generator, which has DC generator and AC generator:
Dc generator is mainly composed of generator housing, magnetic pole core, magnetic field coil, armature and carbon brush. Working power generation principle: When the diesel engine drives the armature of the generator to rotate, because of the remanent magnetic core of the magnetic pole of the generator, the armature coil will cut the magnetic force line in the magnetic field. According to the principle of electromagnetic induction, the magnetic induction generates current and output current through the carbon brush.
The alternator consists of a permanent magnet (called a rotor) made of magnetic material with alternating north and south poles, and an armature coil (called a stator) made of silicon cast iron and wound with multiple sets of series coils. Working power generation principle: the rotor is driven by the diesel engine to cut the axial magnetic force line, the stator alternately arranged magnetic poles in the coil core to form an alternate magnetic field, the rotor rotates a circle, the direction and size of the flux change many times, due to the transformation of the magnetic field, the size and direction of the induction current will be generated in the coil and the current is conveyed by the stator coil.
Regulating characteristics:
Voltage regulation and frequency regulation are different: in a system, the frequency value is the same regardless of the region, the balance of active power is the balance of the whole system; The voltage level is not consistent in different areas of electricity consumption, reactive power balance is mainly in different areas of balance, power plant voltage regulation ability can only reach a small area around it.. Generator in parallel operation, more of a unit used this method to adjust the function of frequency and voltage for the system was not significant, it mainly is to adjust the load distribution between the group, especially in a large system of small units, output size not happen a material impact on voltage and frequency, can be adjusted according to the need of unit. So the regulation of a small generator connected to the grid is much simpler.
When the active power output of the generator is maintained unchanged, the reactive power output and power factor of the generator can be changed by changing the excitation. When the excitation current remains unchanged, increase the active power output, the reactive power output of the generator will decrease, if it is not reduced, it must increase the excitation accordingly.
GENERATOR | Model | GSKA-8500SE | |
Frequency(HZ) | 50 | 60 | |
Max. output(kw) | 6.5 | 7.0 | |
Rated output(kw) | 6 | 6.5 | |
Rated. AC voltage(v) | 120, 220, 230, 240 | ||
Power factor(cosΦ ) | cosΦ =1 | ||
DC output (v) | 12V/8.3A | ||
Phase | Single phase | ||
Alternator type | self-excited, 2-pole, single phase alternator | ||
Starting system | Electric | ||
Operating noise level(at 7m) | 68~72 | ||
Fuel tank capacity(L) | 16 | ||
Continues work(hr) | 7.8 | 7.4 | |
ENGINE | Model | HR192FB | |
Engine type | Single-cylinder, vertical, 4-stroke air-cooled diesel engine | ||
Bore× stroke(mm) | 92×75 | ||
Fuel | 0# or -10# light diesel fuel | ||
LubriCAT-parts-partsion oil volume(L) | 1.65 | ||
Combustion system | Direct lnjection | ||
STANDARD FEATURES | Voltmeter | yes | |
AC Output Socket | 2 | ||
AC circuit breaker | yes | ||
Oil warning light | yes | ||
Oil alert | yes | ||
OPTIONAL FEATURES | DC circuit breaker | optional | |
Calculagraph | optional | ||
Big Wheel | optional | ||
Three phase voltage | optional | ||
Current meter | optional | ||
ATS | optional | ||
Remote control | optional | ||
Welding | optional | ||
DIMENSIONS | Dimension(L× W× H)(mm) | 910× 535× 700 | |
Net weight(kg) | 155 | ||
20FT | 72 |
Company Details
Business Type:
Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company
Year Established:
1985
Total Annual:
4Million-5Million
Employee Number:
50~100
Ecer Certification:
Active Member
Since establishment in 1985, Guangdong ALI Testing Equipment Co., Ltd, a wholly-owned subsidiary of GSKA Group has been providing a wide and complete range of products and services to the society. GSKA has now 16 offices, warehouses and service centres in China, with head office loCAT-part... Since establishment in 1985, Guangdong ALI Testing Equipment Co., Ltd, a wholly-owned subsidiary of GSKA Group has been providing a wide and complete range of products and services to the society. GSKA has now 16 offices, warehouses and service centres in China, with head office loCAT-part...
Get in touch with us
Leave a Message, we will call you back quickly!