China Uv-1800 Double Beam Uv Vis Spectrophotometer 1.8nm Spectral Bandwidth
China Uv-1800 Double Beam Uv Vis Spectrophotometer 1.8nm Spectral Bandwidth

  1. China Uv-1800 Double Beam Uv Vis Spectrophotometer 1.8nm Spectral Bandwidth

Uv-1800 Double Beam Uv Vis Spectrophotometer 1.8nm Spectral Bandwidth

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Supply Ability 1000 set/month
Delivery Time 3-7 days
Packaging Details paper carton
Wavelength Range 190~1100nm
Band Width 1.8nm (0.5nm, 1nm, 4nm, 5nm optional or 0.5 , 1, 2, 4nm adjustable)
Wavelength Accuracy ±0.3nm
Photometric Accuracy ±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
Dimensions(W*D*H) 560×450×230mm
Weight 28Kg
Brand Name HiYi
Model Number UV-1800
Certification CE, ISO13485, ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 1000 set/month Delivery Time 3-7 days
Packaging Details paper carton Wavelength Range 190~1100nm
Band Width 1.8nm (0.5nm, 1nm, 4nm, 5nm optional or 0.5 , 1, 2, 4nm adjustable) Wavelength Accuracy ±0.3nm
Photometric Accuracy ±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A) Dimensions(W*D*H) 560×450×230mm
Weight 28Kg Brand Name HiYi
Model Number UV-1800 Certification CE, ISO13485, ISO9001
Place of Origin China
High Light uv spectrophotometer uv 1800uv 1800 double beam uv vis spectrophotometer1.8nm double beam uv vis spectrophotometer

 UV-1800 Double Beam UV Vis Spectrophotometer

OVERVIEW

 

UV-1800 dual wavelength UV-Vis spectrophotometer, the successful implementation of the stringent requirements of high precision and high reliability of the measurement can meet the requirements of various applications, it can be used in biological research, biotechnology industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection , food hygiene, clinical testing, health and epidemic prevention and other fields to meet the requirements of various applications.

 

 

 

FEATURES

 

  • Improved optimization of optical design, import source and receiver creating a system of high performance and high reliability.
  • Automatic design, to achieve the most simple means of measurement.
  • LSI design greatly improves the scalability and reliability of the system.
  • Measurement data can be output through the printer with USB interface.
  • 1.8nm spectral bandwidth can be customized according to user requirements to install to meet the stringent requirements of pharmacopoeia.
  • Rich measurement methods, with a wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination (optional), dual-wavelength, three wavelength (optional) DNA protein measurement (option) and other measuring methods, can meet different measurements requirements, and can be displayed directly on a 6-inch screen.
  • It could be powered down to save the measurement parameters and data, user-friendly.
  • UV-1800 series dual-beam optical system, successfully achieved the perfect combination of high precision and high reliability of the measurement can meet the requirements of various applications, can be used in biological research, biotechnology industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection , food hygiene, clinical testing, health and epidemic prevention and other areas.
  • Realize spectral scanning by PC software control, more precise and flexible measurement requirements.
  • Wide wavelength range, which can meet various areas of the wavelength range of requirements.
  • Based on user requirements optional hole rack, manual four with rack, manual Eighth rack, automatic Eighth frame, glass frame, test tube rack, 1cm colorimetric frame, 5cm colorimetric frame, 10cm colorimetric racks.

 

SPECIFICATION

 

Optical System Double beam
Wavelength Range 190~1100nm
Band Width 1.8nm (0.5nm, 1nm, 4nm, 5nm optional or 0.5 , 1, 2, 4nm adjustable)
Wavelength Accuracy ±0.3nm
Wavelength Repeatability ≤0.1nm
Photometric Accuracy ±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
Photometric Repeatability 0.15% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
Stray Light ≤0.03% τ (220nm NaI,340nm NaNO2)
Stability 0.0005A/h@500nm
Noise ± 0.0002A @500nm
Baseline Flatness ± 0.001A
Photometric Mode T,A,C,E
Wavelength Setting Automatic
Photometric Display Range -4~4A
Display Mode 6 inches high brightness blue LCD
Detector Import Silicon Photodiode
Light Source Import Deuterium Lamp & Tungsten Halogen Lamp
Power Requirement AC 220V/50Hz 110V/60Hz
Power 120W
Dimensions(W*D*H) 560×450×230mm
Weight 28Kg

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2001

  • Total Annual:

    10000000-15000000

  • Employee Number:

    30~50

  • Ecer Certification:

    Verified Supplier

HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan... HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing HiYi Technology Co., Ltd
  • Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China
  • https://www.hiyipro.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement