FP300 Addressable Fire Alarm Panel

  1. MOQ: 1 set
  2. Price: USD 600 - 750 / set
  3. Get Latest Price
Payment Terms T/T, Western Union, MoneyGram, D/P, D/A, L/C
Supply Ability 1000 SET / week
Delivery Time 1-10 work days
Packaging Details Carton size : 30X20X8 cm
Product name Control Panel
Mains Supply 230VAC (-15%, +10%). 47 ~ 63Hz. Max current 0.8A
Mains Fuse T3.15AL250V
Operating Voltage 18.5 ~ 30VDC
Recommended Mains Cable: Screened or standard/black mains cable, Screened or standard/black mains cable
cable size 0.75mm2
Max. Charging Current 1.2A
Max. Battery Supply Current 4A (when the Mains is disconnected)
Brand Name HiYi
Model Number FP300
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, MoneyGram, D/P, D/A, L/C Supply Ability 1000 SET / week
Delivery Time 1-10 work days Packaging Details Carton size : 30X20X8 cm
Product name Control Panel Mains Supply 230VAC (-15%, +10%). 47 ~ 63Hz. Max current 0.8A
Mains Fuse T3.15AL250V Operating Voltage 18.5 ~ 30VDC
Recommended Mains Cable: Screened or standard/black mains cable, Screened or standard/black mains cable cable size 0.75mm2
Max. Charging Current 1.2A Max. Battery Supply Current 4A (when the Mains is disconnected)
Brand Name HiYi Model Number FP300
Certification CE Place of Origin China
High Light FP300 Addressable Fire Alarm PanelHiYi Addressable Fire Alarm PanelFP300 Addressable Fire Alarm Control Panel

Intelligent LPCB Approved Addressable Fire Alarm System Control Panel

Addressable Fire Alarm System
FP300 Addressable Fire Alarm Control Panel

 

OVERVIEW

 

The purpose of the FP300 Fire Alarm Control Panel (FACP) is to monitor input signals, give indications and possibly activate outputs as programmed.
It is designed to comply with EN 54-2 with qualities of simple installation, operation and easy maintenance. The FP300 panel is an addressable fire detection panel with 1 loop of 324 addressable points and expansion capabilities. It is compatible with other peripherals made by our company with its own protocol.

 

FEATURES & BENEFITS

 

  • Up to 324 addresses on one loop.
  • An easy to read, 4.3'' color screen LCD with a resolution of 480×272.
  • Zone indication and control panel(ZCP) for 32 zones gives a quick indication of the location of an alarm.
  • Record capacity of 1000 historical events for each of historical fire, historical fault and historical operation.
  • An independently programmable conventional sounder circuit output.
  • Integral power supply and battery.
  • Integral printer.
  • Flexible and intuitive cause and effect programming on front panel.
  • Zone test, point test and module start/stop testing facilitate the commissioning
  • U-disk interface makes the load and save of configuration or historical data convenient for system commissioning and maintenance.
  • Hierarchy management with three access levels.
  • Anti-tamper protection by a key lock.
  • CAN bus for interconnection of up to 20 FACPs and RS485 for connection with up to 30 fire indicating panels per FACP.
     

 

APPLICATION

 

Fire alarm system is mostly used for laying fire system in office and commercial places. Any building needs fire alarm system, which can effectively prevent the occurrence of fire and give warning from the source.

 

PRODUCT PARAMENTERS

 

Mains supply 230VAC (-15%, +10%). 47 ~ 63Hz. Max current 0.8A
Mains fuse T3.15AL250V

Operating voltage

18.5 ~ 30V
Recommended mains cable Recommended mains cable
Screened or standard/black mains cable, cable size 0.75mm2
Power rating Imax.a=1.2A; Imax.b=2.6A; Imin=0.65A
Max. charging current 1.2A
Max. internal resistance of battery 1.5Ω
Battery fuse F8AL250V
Quiescent current (full loaded) < 0.4A

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2001

  • Total Annual:

    10000000-15000000

  • Employee Number:

    30~50

  • Ecer Certification:

    Verified Supplier

HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan... HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing HiYi Technology Co., Ltd
  • Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China
  • https://www.hiyipro.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement