Payment Terms | Western Union, L/C, T/T |
Supply Ability | 1000SETS/YEAR |
Packaging Details | WOOD BOX,CARTON BOX,PALLETS |
Color | red |
Certificate | CE,ISO9001,ISO14001 |
Motor | 380v,50hz,3ph |
thermal power | 35kw-10500kw |
Brand Name | YONGXING |
Model Number | BHG5-BHG350P |
Certification | CE,ISO9001,ISO14001,SGS |
Place of Origin | ZHEJIANG |
View Detail Information
Explore similar products
3500kw Industrial Natural Gas Burners Heavy Oil Burner Two Stage Operation
Lpg Industrial Gas Burner / Gas Fired Burner High Strength Alloy Steel Material
Steam Boilers Oil And Gas Burner Dual Fuel Gas Furnace Burners Easy Operate
380v 50hz Light Industrial Gas Burner Compact Industrial Propane Gas Burners
Product Specification
Payment Terms | Western Union, L/C, T/T | Supply Ability | 1000SETS/YEAR |
Packaging Details | WOOD BOX,CARTON BOX,PALLETS | Color | red |
Certificate | CE,ISO9001,ISO14001 | Motor | 380v,50hz,3ph |
thermal power | 35kw-10500kw | Brand Name | YONGXING |
Model Number | BHG5-BHG350P | Certification | CE,ISO9001,ISO14001,SGS |
Place of Origin | ZHEJIANG | ||
High Light | gas furnace burners ,gas package burners |
Italian baltur brand 300kw single gas burner lpg diesel oil burner for steam boiler
single gas burner single-stage operation (on/off) can adapt to any type of combustion chamber. Air and gas are mixed in the combustion head. By adjusting the combustion air and the combustion head, the best combustion parameters can be obtained. The combustion gas is recirculated in the combustion head. It can minimize the emission of pollutants, especially nitrogen oxides (NOx).
The washing unit can be directly removed without removing the burner from the boiler, and the maintenance is convenient. Manually adjust the air flow. A gas train with a leak can be selected.
It is equipped with a seven-hole coupling with a flange and an insulating seal that is attached to the boiler.
The structural feature burner includes a lightweight aluminum alloy fan component, a high performance centrifugal fan with a combustion air inlet for the flow regulating device, and an automatic closing damper.
Sliding flanges paired with various boiler flanges adjust the position of the burner into the boiler. Adjustable burner with steel blast tube and flame spreader.
Single-phase motors drive the fans. The gas train consists of a complete combination of operating valves, safety valves, minimum pressure switches, pressure regulators and gas filters (except for individual valve groups).
Burner automatic control unit and command equipment in line with European EN298 standard. The ionizing electrode detects the flame. A seven-hole coupling outlet is provided for the burner electrical and thermostat.
The microampere meter can be connected to the ionization cable. The standard configuration of electrical protection class IP40, if required, provides electrical protection rating. Silencing plastic protective cover.
Single gas burner for boiler will supply u highest buying experience :
1. CE standard ,comply with 90/396/EEC;PIN63AP6680
2. EMC comply with 89/336/EEC
3. Burner comply IP40,EN60529 protection
4. Burner gas valve comply with EN676
5. Two-stage operation (high/low flame).
6. Compatible with any type of combustion chamber, according to EN303 standard
7. High blowing efficiency, low electrical input, low noise.
8. Air-gas mixing at blast-pipe.
9. Maintenance facilitated by the fact that the mixing unit can be removed without having to remove the burner from the boiler.
Natural gas burner for boiler with famous part ,long life time:
SIEMENS CONTROLLER
DUNGS VALVE
DANFOSS NOZZLE
SUNTEC OIL PUMP
BRAHMA/PARKER SOLENOID VALVE
FIDA TRANSFERMA
SIEMENS SERVOMOTOR
Natural gas burner for boiler DATASHEET FOR REFERENCE
NATRUAL GAS BURNER EMAIL: bettysun001@vip.126.com | |||||||
MODEL | GAS COMBUSTION | BURNER OUTPUT | MAIN SUPPLY | Motor | CONTROL METHOD | ||
NM3/HR | KW | ||||||
MIN | MAX | MIN | MAX | KW | |||
SINGLE STAGE CONTROL | |||||||
YXG5 | 3 | 5.7 | 30.06 | 56.3 | 1N-220V 50HZ | 0.11 | ONE STAGE |
YXG6 | 3 | 5.7 | 30.06 | 56.3 | 1N-220V 50HZ | 0.11 | ONE STAGE |
YXG11 | 4.8 | 10 | 48.8 | 99 | 1N-220V 50HZ | 0.11 | ONE STAGE |
YXG10 | 4.8 | 99 | 48.8 | 99 | 1N-220V 50HZ | 0.15 | ONE STAGE |
YXG17 | 7 | 17 | 69 | 169 | 1N-220V 50HZ | 0.15 | ONE STAGE |
YXG20 | 5.85 | 20.1 | 80 | 200 | 1N-220V 50HZ | 0.37 | ONE STAGE |
YXG30 | 6 | 30 | 60 | 300 | 1N-220V 50HZ | 0.37 | ONE STAGE |
YXG35 | 9 | 35.8 | 90 | 359 | 1N-220V 50HZ | 0.37 | ONE STAGE |
YXG34 | 12 | 38 | 118 | 338 | 3N-380V 50HZ | 0.37 | ONE STAGE |
YXG40 | 19 | 43 | 185 | 425 | 3N-380V 50HZ | 0.55 | ONE STAGE |
YXG50 | 17 | 60 | 169 | 586 | 3N-380V 50HZ | 0.55 | ONE STAGE |
TWO STAGE CONTROL | |||||||
YXG20P | 5.85 | 20.1 | 80 | 200 | 1N-220V 50HZ | 0.37 | TWO STAGE |
YXG30P | 6 | 30 | 60 | 300 | 1N-220V 50HZ | 0.37 | TWO STAGE |
YXG35P | 9 | 35.8 | 90 | 358 | 1N-220V 50HZ | 0.37 | TWO STAGE |
YXG34P | 12 | 38 | 118 | 338 | 3N-380V 50HZ | 0.37 | TWO STAGE |
YXG40P | 19 | 43 | 185 | 425 | 3N-380V 50HZ | 0.55 | TWO STAGE |
YXG50P | 17 | 60 | 169 | 586 | 3N-380V 50HZ | 1.5 | TWO STAGE |
YXG60P | 25 | 75 | 248 | 738 | 3N-380V 50HZ | 1.5 | TWO STAGE |
YXG100P | 28 | 101 | 280 | 995 | 3N-380V 50HZ | 2.2 | TWO STAGE |
YXG120P | 35 | 121 | 350 | 1200 | 3N-380V 50HZ | 2.2 | TWO STAGE |
YXG150P | 42 | 144 | 414 | 1428 | 3N-380V 50HZ | 3 | TWO STAGE |
YXG200P | 60 | 202 | 590 | 2000 | 3N-380V 50HZ | 3 | TWO STAGE |
YXG250P | 50 | 253 | 490 | 2500 | 3N-380V 50HZ | 7.5 | TWO STAGE |
YXG300P | 66 | 313 | 657 | 3100 | 3N-380V 50HZ | 7.5 | TWO STAGE |
YXG350P | 93 | 350 | 924 | 3500 | 3N-380V 50HZ | 9 | TWO STAGE |
BQ SEARIES
YONGXING BOILER GROUP CO.,LTD ------Bonarate burner sales@yxboiler-factory.com | |||||||
BQ SERIES GAS BURNER | |||||||
Burner model | Suitable for boiler (TON/H) | Burner thermal power (KW) | Burner thermal power (CAL/H) | Gas Consume (NM3/H) | Fan power (KW) | Applicable fuel | Adjust Method |
BQ6 | 1 | 175-940 | 151,000-808,000 | 17.5-94 | 1.5 | CITY GAS, NATURAL GAS, LPG GAS gas heat value 36Mj/M3 | Z-Sliding two stage R-Mechanical ratio control E-Electronic proportional control |
BQ10 | 1.5 | 300-1750 | 258,000-1,505,000 | 30-175 | 3 | ||
BQ15 | 2 | 400-2250 | 344,000-1,935,000 | 40-225 | 4 | ||
BQ20 | 3 | 500-3500 | 430,000-3,010,000 | 50-350 | 7.5 | ||
BQ30 | 4 | 500-4080 | 430,000-3,509,000 | 50-408 | 10 | ||
BQ35 | 5 | 900-4780 | 774,000-4,110,000 | 90-478 | 12 | ||
BQ40 | 6 | 700-5400 | 602,000-4,644,000 | 70-540 | 13.5 | ||
BQ55 | 8 | 1000-8150 | 860,000-7,009,000 | 100-815 | 15 | ||
BQ70 | 10 | 1000-10500 | 860,000-9,030,000 | 100-1050 | 22 |
We need to ask you some details for sending you the more suitable quotation
1. what is the application of the burner ?(for food industry ,textile industry, chemical industry or others )
2. what is the capacity per hour do you need?(how many kw ?)
3. which fuel do you want to use for your boiler?(oil or gas,lpg,kerosene and etc ?)
Pls send us effiicent info to get the price soonest.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Trading Company,Seller
Year Established:
2000
Total Annual:
100-500
Employee Number:
500~1000
Ecer Certification:
Active Member
Yongxing Boiler Group Co., Ltd. is a group company specializing in research, development, manufacturing, sales and installation services for various boilers and various thermal energy machinery and equipment. Yongxing Boiler occupies an area of 60,000m2, with fixed assets of 15 mil... Yongxing Boiler Group Co., Ltd. is a group company specializing in research, development, manufacturing, sales and installation services for various boilers and various thermal energy machinery and equipment. Yongxing Boiler occupies an area of 60,000m2, with fixed assets of 15 mil...
Get in touch with us
Leave a Message, we will call you back quickly!