Payment Terms | T/T, L/C, Western Union |
Supply Ability | USD1000/SET |
Delivery Time | 10-15days |
Packaging Details | Nude packing |
Type | DZL/SZL type |
Standard | GB ,ASME |
Material | Boiler Steel |
Capacity | 1ton-20ton |
Brand Name | YONGXING |
Model Number | DZL |
Certification | ISO9001,ISO14001,SGS,BV |
Place of Origin | HENAN |
View Detail Information
Explore similar products
Steel Q345R Material Coal Fired Steam Boiler In Textile Industry 4 Ton Chain
Large Stove Sawdust Fired Boilers / Wood Pellet Fired Steam Boiler 6000Kg Steam
Industrial Steam Generator Furnace Q345R Steel Plate Material Furnace High
8 Ton Coal Fired Steam Boiler With Energy Saving Light Chain Grate ISO9001
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | USD1000/SET |
Delivery Time | 10-15days | Packaging Details | Nude packing |
Type | DZL/SZL type | Standard | GB ,ASME |
Material | Boiler Steel | Capacity | 1ton-20ton |
Brand Name | YONGXING | Model Number | DZL |
Certification | ISO9001,ISO14001,SGS,BV | Place of Origin | HENAN |
High Light | coal fired water tube boiler ,coal fired central heating boilers |
DZL 6 ton industrial automatic coal fired steam boiler with chain grate stoker
Introduction
1. The DZL series boiler is a horizontal three return fire tube boiler, and the combustion equipment is a chain grate.
2. The water-cooling wall on the left and right sides of the furnace is a radiant heating surface, the two wings of the furnace are convective heating surfaces, the convection heating surface of the threaded tobacco pipe is arranged in the drum, and the front and rear arches are made of a heat-resistant concrete integrally cast enamel. The outside of the boiler main body is a shield housing.
3. The fuel falls from the coal hopper the front part of the grate. As the grate runs, the coal undergoes preheating, retorting, ignition, and burning. The slag falls into the slag bucket, and is discharged from the furnace at any time by the slag removing machine.
5. The rear arch can form a vortex and air to fully mix, and heat the front arch to improve the fire condition.
6. The upper wing of the arch exits into the two-wing convection water wall bundle, enters the threaded pipe through the front smoke box, passes the economizer and the dust collector, led by the induced draft fan to the chimney.
Auxiliary Data
Parts Type
1. Chain Grate Travelling grates OR flake type chain grates
2. Induced Draft Fan GY1-18 4#Right 0°, Electromotor Y 132S-4B3
3. Forced Draft Fan 4-72-3.2A Right 315°, Electromotor Y 90L-2
4. Electric Pump JGGC2-8X13, Electromotor Y 90L-2
5. Govenor Stepless speed governor, Electromotor YCT112-4A
6. Ash Extractor Screw type, Electromotor Y 90S-6
7. Dust Collector Multi-tube XTD-1
Data sheet 1
Parameter | Data |
Rated evaporation capacity | 6 ton/h |
Rated working pressure | 1.25MPa |
Rated steam temperature | 193℃ |
Water-supply temperature | 20℃ |
Boiler heating area | 216.4㎡ |
Grate area | 7.54㎡ |
Thermal efficiency | 80.32% |
Exhaust temperature | 125℃ |
Boiler Water volume | 10.2m³ |
Dimension(L*W*H) | 7.42m*3m*3.67m |
Data sheet 2
Model | DZL1-A II | DZL2-A II | DZL 4-A II | DZL8-A II |
Rated evaporation capacity (T) | 1 | 2 | 4 | 8 |
Rated working pressure (MPa) | 0.7/1.0/1.25 | 0.7/1.0/1.25 | 1.25/1.6 | 1.25/1.6 |
Rated steam temperature (℃) | 170/184/194 | 170/184/194 | 194/204 | 194/204 |
Water-supply temperature(℃) | 20 | 20 | 20 | 20 |
Boiler heating area (㎡) | 57.47 | 89.4 | 124.9 | 432.22 |
Grate area (㎡) | 2.7 | 3.45 | 5.9 | 10.81 |
Exhaust flue gas temperature (℃) | 120.7 | 157 | 167 | 163.41 |
Thermal Efficiency (%) | 80.42 | 78.4 | 79.7 | 79.36 |
Size (m) | 5.27*2.5*3.15 | 5.4*2.4*3.48 | 6.18*2.95*3.35 | 9.05*3.2*4.- |
General standard
1. The boiler assembly shall be in accordance with ,2000 edition and JB/ t7985-2002, .
2. The boiler is designed according to normal pressure. The top of the furnace body is provided with an air outlet. The boiler runs without pressure and the combustion operation is safe and reliable. Atmospheric hot water boilers can be installed in any place where they are used, and are not subject to a wide range of annual inspection procedures, and have been rapidly developed in recent years.
Welcome inquiry more specifications if u need .
Quckly installed boiler | |||||
boiler model | Unit | DZL1-0.7/1.0-AII | DZL2-0.7/1.0-AII | DZL4-0.7/1.25/1.6-AII | DZL6-1.25/1.6-AII |
capacity | ton/h | 1 | 2 | 4 | 6 |
rated pressure | Mpa | 0.7/1.0 | 0.7/1.0 | 0.7/1.25/1.6 | 1.25/1.6 |
rated steam temeperature | ℃ | 170/184 | 170/184 | 184/193/204 | 193/204 |
feed water temperature | ℃ | 20 | 20 | 20 | 105 |
radiation area | ㎡ | 4.21 | 6.43 | 10.55 | 16.95 |
convection area | ㎡ | 20.68 | 39.23 | 90.45 | 134.87 |
economizer area | ㎡ | 9.66 | 16.56 | 16.56 | 53.13 |
valid grate area | ㎡ | 1.852 | 3.15 | 5.18 | 8.395 |
applicable fuel | * | COAL | COAL | COAL | COAL |
exhaust gas temperature | ℃ | 152/160 | 152/161 | 163/163.8/169.5 | 163/169 |
design efficiency | % | 77.73/77.24 | 78.53/78.18 | 79.37/79.30/78.96 | 79.83/79.19 |
fuel consumption | kg/h | 170.74/172.93 | 341.71/343.63 | 673.22/676.27/682.11 | 866.39/877.51 |
max part size for delivery | mm | 5488*2254*2782 | 5694*2704*3324 | 6743*2954*3508 | 8244*2951*3704 |
TWO PART ASSEMBLED BOILER | ||||||||
boiler model | Unit | SZL6-1.25/1.6-AII | SZL8-1.25/1.6-AII | SZL10-1.25/1.6-AII | SZL12-1.25/1.6-AII | SZL15-1.25/1.6-AII | SZL20-1.25/1.6-AII | SZL25-1.25/1.6-AII |
capacity | ton/h | 6 | 8 | 10 | 12 | 15 | 20 | 25 |
rated pressure | Mpa | 12.5/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 |
rated steam temeperature | ℃ | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 |
feed water temperature | ℃ | 105 | 105 | 105 | 105 | 105 | 105 | 105 |
radiation area | m2 | 18.19 | 22.14 | 25.8 | 25.8 | 34.117 | 53.78 | 99.21 |
convection area | m2 | 121.9 | 158.86 | 200.38 | 250.17 | 331.616 | 411.8 | 457.78 |
economizer area | m2 | 53.13 | 104.64 | 130.8 | 174.4/261.1 | 117.72/117.2 | 212.4 | 476.16 |
valid grate area | m2 | 7.55 | 9.34 | 10.98 | 12.78 | 16.24 | 20.84 | 24.76 |
applicable fuel | COAL | COAL | COAL | COAL | COAL | COAL | COAL | |
exhaust gas temperature | ℃ | 165.78/169.85 | 161/165 | 160/162 | 158/150 | 156.7/159.4 | 153/159 | 152/156 |
design efficiency | % | 80.11/79.44 | 79.95/79.98 | 80.55/80.28 | 80.68/80.72 | 80.48/80.56 | 81.09/80.77 | 81.38/81.26 |
fuel consumption | kg/h | 863.28/874.78 | 1153.42/1161.38 | 1430.96/1442.74 | 1714.5/1721.8 | 2167.89/2164.7 | 2868.63/2884.7 | 3551/3556 |
max part size for delivery | mm | 7100*2800*3500 7300*2540*2330 | 7300*3000*3500 7400*2700*2330 | 7600*3200*3500 7700*2900*2330 | 7600*3200*3500 8500*2900*2330 | 7350*3373*3505 8904*3370*1100 | 7814.7*3573*3511 9439*3768*1100 | 8478*2600*2740 Bulk packing |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Trading Company,Seller
Year Established:
2000
Total Annual:
100-500
Employee Number:
500~1000
Ecer Certification:
Active Member
Yongxing Boiler Group Co., Ltd. is a group company specializing in research, development, manufacturing, sales and installation services for various boilers and various thermal energy machinery and equipment. Yongxing Boiler occupies an area of 60,000m2, with fixed assets of 15 mil... Yongxing Boiler Group Co., Ltd. is a group company specializing in research, development, manufacturing, sales and installation services for various boilers and various thermal energy machinery and equipment. Yongxing Boiler occupies an area of 60,000m2, with fixed assets of 15 mil...
Get in touch with us
Leave a Message, we will call you back quickly!