China factories

China factory - Shenzhen HRD SCI&TECH CO.,Ltd

Shenzhen HRD SCI&TECH CO.,Ltd

  • China,Shenzhen ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Powerwell Max Series High Frequency Ups 10-40kva 380/220vac
China Powerwell Max Series High Frequency Ups 10-40kva 380/220vac

  1. China Powerwell Max Series High Frequency Ups 10-40kva 380/220vac
  2. China Powerwell Max Series High Frequency Ups 10-40kva 380/220vac

Powerwell Max Series High Frequency Ups 10-40kva 380/220vac

  1. MOQ: 5PCS
  2. Price: 2050USD-11000USD/PCS
  3. Get Latest Price
Payment Terms TT or LC
Supply Ability 1000PCS/MONTH
Delivery Time 4weeks after down payment
Packaging Details 1PCS/CTN
Warranty 3 years after shipment
Brand Name HRD/ODM/ODM
Model Number PWM3310,PWM3320,,,PWM3340
Certification CE, ISO9001
Place of Origin Shenzhen China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms TT or LC Supply Ability 1000PCS/MONTH
Delivery Time 4weeks after down payment Packaging Details 1PCS/CTN
Warranty 3 years after shipment Brand Name HRD/ODM/ODM
Model Number PWM3310,PWM3320,,,PWM3340 Certification CE, ISO9001
Place of Origin Shenzhen China
High Light high frequency ups 40kva380vac high frequency upshigh frequency online ups 10kva

POWERWELL series Online HF UPS 3/3phase 10-40kVA, 380/220Vac,Line to Line

 

Powerwell Max series 3 phase  UPS  is a high end uninterruptible power supply, which has adopted the world leading electrical and electronic technology to increase performance and  super high reliability(MTBT>200,000h). 3nos high speed DSPs with completed digital control fully ensure highest quality of power supply and UPS reliability. Being kin to 1.0 input power factor and less than 2% THDi lead this UPS green and energy saved. It also offers humanization design: full front access of service ability, user- friendly touch screen. 

Perfect Applications:

Internet Service, Middle Data Center, Medium-scale network system / computing center, bank and securities, business server group, Medium-scale office automation, precision equipment, etc.

Features: complete digital control technology

Fully digital control with two DSPs, all the subsystems are digital controlled including the IGBT rectifier, inverter, charger, discharger.

Excellent electrical properties

True online double conversion offers the safe and effective power protection for various loads, with strong output load capacity

High input power factor, green and energy-saving

Input with PFC and input PF of the whole UPS up to 0.99, THDi less than 2%

Dual AC input source supportable

Supportable AC and bypass separate input AC source

Strong environmental adaptability 

Wide input voltage and frequency range, adaptation to all kinds of power grid and almost any kinds of generator

Comprehensive protection measures 

Surge Protection, short circuit protection, and other protection to ensure the reliability of UPS system;

IGBT and SCR adopt the advanced EUPEC power module;

The adoption of advanced technology (IGBT driving technology, IGBT soft over-current shutdown, VCE protection) highly improves the reliability and safety of inverter.

Similar modular design

Each phase main board are designed like rack for easy assembling and maintenance

Inbuilt battery pack plug-in design for easy use

Intelligent battery management (ABM)

Adopting the intelligent battery management, extending battery lifespan extremely;

Intelligent interval  three-stage charging process( constant current, constant voltage, float charging and charger shut off, when battery voltage decrease to a lower level, charger restarts to work);

Automatic temperature compensation,( -0.11% per °C ), to extremely extend battery life by 30% and minimize the maintaining work;

 

Online detecting battery status

The max battery charging current can set by end users according to the battery features, to avoid any damage caused by the big charging current;

Back up time displayed on the LCD screen

Periodic self-test battery, detecting the battery problems timely

With battery inverse connection, over voltage / current protection, to protect the battery

Cold start and AC start Function

Directly start the UPS through battery or start UPS through Mains only.

Superior network monitoring capabilities 

Communication port (RS232, RS485, dry contact and so on) connecting with computer, SNMP card optional,

Easy-maintenance design (MMTM<0.5h)

a) Adopts the full front maintenance design, reducing the restrictions on the installation space, and saving the space of computing center

b) Modular design class, convenient and easy site maintenance

c) With manual maintain bypass

d) Battery replacement without disrupting the UPS running

e) Historical records classified with search function, events up to1,000 items

Advanced parallel technology:

With digital control technology for cycle current control, parallel system with very high reliable and up to 6units, and sharing common battery;

Friendly interface with touch screen :

 

Model PWM3310 PWM3315 PWM3320 PWM3330 PWM33040
Main Input
Grid System 3 Phases + Neutral + Ground
Rated Input Voltage 380/400/415VAC (Line-Line),50/60Hz
Input Voltage Range 304~478Vac (Line-Line),full load;
228V~304Vac (Line-Line),load decreases linearly according to the min phase voltage
Input Frequency Range 40Hz~70Hz
Input Power Factor >0.99
Input Current THDi <4% (full Linear Load) <3% (full Linear Load)
Bypass Input
Rated Bypass Voltage 380/400/415VAC (Line-Line),50/60Hz
Bypass Voltage Range Selectable, default -20%~+15%;Upper limit: +10%, +15%, +20%, +25%;
Lower limit: -10%, -15%, -20%, -30%, -40%
Bypass Frequency Range Selectable, ±1Hz, ±3Hz, ±5Hz
Bypass Overload 125% Long term operation;125%~130% for 10min;130%~150% for 1min;
Output
Rated Inverter Voltage 380/400/415VAC (Line-Line),50/60Hz
Output Power Factor 1.0 1.0
Voltage precision ±1.5%(0-100% linear load)
Transient Response <5% for step load (20% - 80% -20%)
Transient recovery < 30ms for step load (20% - 100% -20%)
Output Voltage THDu <1% (linear load),<5.5% (non-linear load) <1% linear load;<6% (non-linear load)
Inverter Overload <110%, 60min;110%~125%,10min;125%~150%,1min;
Frequency Regulation 50/60Hz±0.1%
Synchronized Range Settable, ±0.5Hz ~ ±5Hz, default ±3Hz
Synchronized Slew Rate Settable, 0.5Hz/S ~ 3Hz/s, default 0.5Hz/s
Battery And Charger
Battery Rate Voltage ±192-240VDC
Charger precision 1%
Charger Power max=20% System Power
Efficiency
Normal Operation 95%max >95% >96%
Battery Operation 94.5%max >95% >96%
System
Display      7 inch touch screen
Interface Standard: RS232, RS485
Option: SNMP, Dry Contact, Parallel kit,Battery cold start
Environmental
Operation Temperature 0 ~ 40 ℃
Storage Temperature -40 ~ 70 ℃
Relative Humidity 0 ~ 95% (Non condensing)
Noise (1 meter) 58dB @ 100% load, 52dB @ 45% load 65dB @ 100% load, 62dB @ 45% load
Physical data
Dimension
(W*D*H,mm)
250*660*530 250*840*715 250*660*530 250*840*715 250*680*770 350*738*1335 250*680*770 350*738*1335 250*836*770 500*840*1400
Weigh(Kg) 31 51.5
(without battery)
31 51.5
(without battery)
50 89
(without battery)
52 89
(without battery)
61 140

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2010

  • Total Annual:

    15,000,000-200,00,000

  • Employee Number:

    300~500

  • Ecer Certification:

    Verified Supplier

  About  HRD ,founded in 2010, after more than 14 years fast development,HRD has grown into a large leading professional UPS manufacturer with ISO9001:2015 , ISO14001,ISO18001 certified Based on  strong high level professional R&D team with...   About  HRD ,founded in 2010, after more than 14 years fast development,HRD has grown into a large leading professional UPS manufacturer with ISO9001:2015 , ISO14001,ISO18001 certified Based on  strong high level professional R&D team with...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen HRD SCI&TECH CO.,Ltd
  • 1st floor, 56A building, Bao’tian Industrial Park,Xixiang Town Bao’an District, Shenzhen City
  • https://www.hrdups.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement