Payment Terms | L/C, T/T |
Supply Ability | 30 set per month |
Delivery Time | 20 days |
Packaging Details | Plywood |
MATERIAL | Stainless steel |
STATION | 1 Station |
CLAMP UNIT | Plug Pin Clamp Unit |
STANDARD | IEC60884.1, VDE0620 |
WEIGHTS | 4N, 20N, 30N, 50N |
GAUGES | Customizable |
Brand Name | HongCe |
Model Number | HC9928 |
Certification | Calibration certificate(cost additional) |
Place of Origin | China |
View Detail Information
Explore similar products
IEC60884-1 Plug Socket Tester Temperature Rising Tester 0-125A Testing Current
Switch Plug Socket Endurance Tester 6 Stations For Rotary Switch Synchronization
Figure 21 Plug Cord 999999 Flexibility Test Apparatus
VDE0620-1 Measuring Gauges For Checking Dimensions Of Germany Plugs And Sockets
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 30 set per month |
Delivery Time | 20 days | Packaging Details | Plywood |
MATERIAL | Stainless steel | STATION | 1 Station |
CLAMP UNIT | Plug Pin Clamp Unit | STANDARD | IEC60884.1, VDE0620 |
WEIGHTS | 4N, 20N, 30N, 50N | GAUGES | Customizable |
Brand Name | HongCe | Model Number | HC9928 |
Certification | Calibration certificate(cost additional) | Place of Origin | China |
High Light | electric socket tester ,electrical plug tester |
Standard:
IEC 60884-1 'Plugs and socket-outlets for household and similar purposes – Part 1: General requirements' clause 24.10, Figure 30
Standard description:
The plug is placed on a rigid steel plate provided with holes suitable for the pins of the plug as shown as an example in figure 30.
The distances between the centres of the holes (for example, d1 and d2) shall be the same as the distances between the centres of the circle circumscribed around the cross-sectional area of each pin in the standard sheet of the plug.
Each hole shall have a diameter equal to that of the circle circumscribed around the crosssectional area of the pin plus (6 ± 0,5) mm.
The plug is positioned on the steel plate in such a way that the centres of the circles circumscribing the pins coincide with the centres of the holes.
A pull P equal to the maximum withdrawal force as given in table 16, is applied, without jerks, for 1 min on each pin in turn, in the direction of the longitudinal axis of the pin.
The pull is applied within a heating cabinet at a temperature of (70 ± 2) °C, 1 h after the plug has been placed in the heating cabinet.
After the test, the plug is allowed to cool down to ambient temperature and it shall be verified that no pin has been displaced in the body of the plug by more than 1 mm.
Test sample: Plug, pin
Parameters:
Test station | 1 station |
Test weight | 50N*1, 20N*2, 30N*1, 4N*1 |
Gauges | provide 6A plug gauge, 10A plug gauge, 16 plug gauge, one each |
Socket | The socket plate should be made according to specific country's plug and socket requirements. |
Application:
It is used for testing the firmness of the plug and the plug pin. The plug is placed on a rigid steel plate provided with holes suitable for the pins of the plug. The distance between the centers of the holes shall be the same as the distances between the centers of the circle circumscribed around the cross-sectional area of each pin in the standard sheet of the plug.
Test Method
1. Before first use, user should familiar with the relevant standards for more effective and proper using the test apparatus and completing the test.
2. The plug is positioned on the steel plate in such a way that the centers of the circles circumscribing the pins coincide with the centers of the holes. Then insert the test plug into the socket in the direction of the longitudinal axis of the pin. After that, the plug is placed in the heating cabinet with temperature (70 ± 2) °C, 1 h after, a pull force is applied inside a heating cabinet
3. Choose the clamping fixture according to the shape of the plug, and make it is firmly connected with the plug (ensure it will not loose when exert a pull force)
4. Choose the pull force weight according to the maximum withdrawal force as given in table 16 (can be achieved by the superposition), the weight is hooked in the ring of the clamp, handle with care, and don’t produce explosive tension.
5. The force is applied on each plug pin for 1 min, after the test, the plug is allowed to cool down to ambient temperature and it shall be verified that the displacement of any plug pin in the plug body should not excess 1 mm.
6. Pay attention to the cleaning of the device and maintenance of the sockets after the test is completed.
Picture View
Company Details
Business Type:
Manufacturer
Year Established:
2003
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou HongCe Equipment Co., Ltd (hereinafter referred to as HongCe) is located in Guangzhou, China, since 2003, engaged in developing and providing test equipment and detection system for electronic & electrical products, house appliances and other products. HongCe is professionally dedicate... Guangzhou HongCe Equipment Co., Ltd (hereinafter referred to as HongCe) is located in Guangzhou, China, since 2003, engaged in developing and providing test equipment and detection system for electronic & electrical products, house appliances and other products. HongCe is professionally dedicate...
Get in touch with us
Leave a Message, we will call you back quickly!