China factories

China factory - Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

  • China,Shanghai ,Shanghai
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China 40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter
China 40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter

  1. China 40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter
  2. China 40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter
  3. China 40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter
  4. China 40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter
  5. China 40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter
  6. China 40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter
  7. China 40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter
  8. China 40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter
  9. China 40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter
  10. China 40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter

40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter

  1. MOQ: 1pc
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T
Supply Ability 500pcs per month
Delivery Time 7-10 working days
Packaging Details In Carton or Wooden Box
Product Name Water Electromagnetic Flowmeter
Pipeline Diameter 150
Accuracy 0.5%
Output 4-20mA / Pulse / RS485
Electrode 316SS, Hc, Ta, Ti, Others
IP Class IP65/IP68
Power supply 220VAC/110VAC, Battery
Connection Flange, Clamp, Thread, Clamping
Type Electromagnetic Flow Meter
Medium Sea water, Conductive Fluid, Liquid, Milk Beer Drink Water, Conductivity>0.5us/㎡
Pressure 0.6MPa,1.0MPa,1.6MPa,2.5MPa,4.0MPa
Working pressure 1.6MPa, DIN, JIS
Brand Name
Model Number MLF
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 500pcs per month
Delivery Time 7-10 working days Packaging Details In Carton or Wooden Box
Product Name Water Electromagnetic Flowmeter Pipeline Diameter 150
Accuracy 0.5% Output 4-20mA / Pulse / RS485
Electrode 316SS, Hc, Ta, Ti, Others IP Class IP65/IP68
Power supply 220VAC/110VAC, Battery Connection Flange, Clamp, Thread, Clamping
Type Electromagnetic Flow Meter Medium Sea water, Conductive Fluid, Liquid, Milk Beer Drink Water, Conductivity>0.5us/㎡
Pressure 0.6MPa,1.0MPa,1.6MPa,2.5MPa,4.0MPa Working pressure 1.6MPa, DIN, JIS
Brand Name Model Number MLF
Place of Origin China

                                    40mm Electromagnetic Flow Meter Water 80 Deg Heat Meter BTU Meter

 

1. Introduction

MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction, and is composed of sensors and converters. Used to measure the conductivity of liquid or solid. In general, its conductivity should be greater than 5μs/cm (tap water and raw water conductivity is about 100 ~ 500μs/cm), and it can also be used to measure acid, alkali, brine, pulp or pulp and other media. However, these media cannot contain a large amount of magnetic substances and bubbles.

 

2.Working Principle

The principle of the sensor is based on Faraday’s law of electromagnetic induction.It is installed a pair of detection electrodes on the pipe wall,where the measurement pipe axis and magnetic field lines are vertical. When the conductive liquid cuts magnetic field lines and produces induced electromagnetic force.Which can be measured by the two electrodes on the meter pipe.The result can be calculated by formula: Induced electromotive force,(flow signal)E=KBDV

E——Induced electromotive force,V;

K——meter constant;

B——Magnetic flux density,T;

D——Internal diameter of measuring pipe,m;

V——Average velocity of pipe section,m/s.

MLF Series Electromagnetic Flow Meter

Assume the volume of liquid as qv(m3/s),qv=πD2V/4),so in the formula E=(4kB/πD)qv=kqv,K is meter constant,K=4kB/πD.

Actually, the electromagnetic flow meter consists of two parts, transmitter and sensor, the measuring electrodes inspect the electromotive force, and transmit to the converter, the converter provides excitation current.E is usually called a flow signal, after processing the flow signal by converter, output 4~20 mA/pulse(or frequency) signal which is proportional to the flow rate, then the flow rate recording,adjusting can be achieved.

 

 

3. Specification

MLF Type Divided Type Integrated Type Explosive Proof Integrated Type Battery Powered Type Heat Energy Type
Accuracy ±0.2% or ±0.5%
Pipeline Diameter DN10-DN2000 DN10-DN600 DN25-DN2000
Flange GB, ANSI, JIS, BS, Others
Pressure DN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner Material CR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity ≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection Class IP65, IP66, IP67, IP68
Medium Temperature -25~180
(Please refer to liner material)
-25~80(Please refer to liner material) -25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence <±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability ≤±0.1% or ±0.25%
Analog Output Error ≤±0.02mA
Velocity 0.3~10m/s
Electrical connection M20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output 4-20mA, Pulse, RS485, Hart, Profibus

 

 

4.Selection of Electrode Materials

 

316L Good resistance to the corrosion of nitric acid, <5% sulfuric acid under room temperature, acetic acid, alkaline fluid, sulfite under certain pressure, seawater and scetic acid, etc. It can be widely used in petrochemical urea, vinylon.
Hb Good resistance to the all the concentration of hydrochloric acid below the boiling point, also resistance tothe corrosion of non-oxidizing acid, alkali, salt like sulfuric acid phosphoric acid hydrofluoric acid, organic acids.
Hc Resistance to the corrosion of oxidizing acids like metric acid, mixed acid. The mixture of chromium acid and sulfuric acid, and salts of oxidative, like Fe3+, Q3+, and some other oxidants, like hypochlorite salt solution higher than normal tmperature and seawater.
Ti Resistance the corrosion of seawater, various chlorides, hypochlorite, oxidizing acid(including fuming nitric acid), and organic acid or alkali, but don't be resistance to the corrosion of pure reducint acid(like sulfuric acid, hydrochloric acid). But if acid includes oxidants(like nitric acid, Fe3+, Q3+), the corrosion resistance will decrease.
Ta Good corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-Ir Have good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten Carbide For pulp and sewage, good resistance to solid particle interference.

 

 

5. Configuration

MLF Series Electromagnetic Flow Meter Configuration
Model MLF
Sensor Installation S Flange Type Sensor
C Insertion Type Sensor
O Others
Pipeline Diameter 10 10mm
15 15mm
20 20mm
......  
2000 2000mm
Electrode Installation F Standard Fixed Type
Electrode Material A 316L SS
B Hb
C Ta
D Ti
E Hc
F Tungsten Carbide
G Others
Liner Material R Rubber
P PTFE
O Others
Pipe Material B 304 SS (Standard)
C 316 SS
Flange Type G GB (Standard)
A ANSI
J JIS
B BS
O Others  
Flange Material A 304 SS
B 316 SS
C #20 Carbon Steel (Standard)
Cover Material D 304 SS
E 316 SS
F Carbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange 0 Without Matching Flange (Standard)
1 With Matching Flange
Ground Ring 0 Without Ground Ring (Standard)
1 With Ground Ring
Rated Pressure 10 1.0MPa
16 1.6MPa
25 2.5MPa  
40 4.0MPa
Working Temperature E ≤60℃
H ≤180℃(Divided Type)
Type I Integrated Type
D Divided Type
Output P Pulse
A 4-20mA
G RS485
H Hart
Q Others
Power Supply 0 220VAC
1 24VDC
2 Battery-powered
Protection Class 0 IP65 (Integrated/Divided Type)
1 IP67 (Divided Type)
2 IP68 (Divided Type)
Other Features R Heat Energy Function
P With PT1000
B Without PT1000
Explosion Proof 0 None
EX Explosive Proof

 

6. Maintance

The electromagnetic flowmeter has a self-diagnostic function. In addition to power supply and hardware circuit failures, the system also alarms other failures in general use. These messages will give corresponding prompts in the lower right corner of the screen.


1 Maintenance and repair
a) The sensor installation site should meet the requirements of Section 4, please keep the housing tidy;
b) The transmitter should be placed in a clean, ventilated and dry place;
c) It needs to be inspected every two years. For high-precision users, the instrument needs to be submitted for review.

2 Transportation and storage
a) The instrument must be packaged before transportation, and be handled with care when loading and unloading.
b) The storage place must be dry and ventilated to avoid corrosive gases, and the ambient temperature should not be too low or too high;
c) The storage time should not exceed three years.

3. Unpacking inspection
a) The package cannot be opened with a heavy hammer, be careful not to damage the instrument
b) Check the contents carefully according to the packing list.

 

 

 7.Company Profile

 

Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.


Our products are widely used in various fields, including electricity, chemical industry, metallurgy, brewing, oil and gas, textile, water conservancy, environmential protection, etc.

We own independent-courtyard modemized manufacturing workshops and an open office building. Melan has accumlated production and management experience in instruments from European and American and domestic famous companies.

We own first-class talent team, and all the products have reached advanced level at home and abroad. We provide our customers with complete and professional test control solutions and high-tech and high-quality products.

Melan is your reliable friend and partner. We are willing to try our best as dedication and perfection as motivation.

 

8.FAQ

Q: How long will you give me the reply?
A: We will contact you in 5 hours as soon as we can.

Q: What is the warranty of your prducts?
A: Our warranty is 12 months after the shipping date.

Q: What is the lead time of your products?
A: Normally our factory lead time is 10-12 working days.

Q: Can I OEM your products?
A: OEM and ODM customization are welcomed.

Q: What is your MOQ?
A: We have no MOQ limit, small quantity order is acceptable.

Q:What is the transport?
A: Express such as DHL, FedEx, UPS for freight prepaid, and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by sea.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2019

  • Total Annual:

    $1000000-$2000000

  • Employee Number:

    >50

  • Ecer Certification:

    Site Member

Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.   Our products are widely used in various fields, including electricity, chemical ... Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.   Our products are widely used in various fields, including electricity, chemical ...

+ Read More

Get in touch with us

  • Reach Us
  • Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
  • No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China
  • https://www.industrial-flowmeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement