Payment Terms | L/C, T/T,, Western Union, MoneyGram |
Supply Ability | 100KM/Week |
Delivery Time | 7-15 working days |
Packaging Details | wooden drums according to quantity and container or required |
Model name | H07RN-F YC YCW, H05RN-F |
Conductor Type | Flexible Copper (claass5) |
High light | rubber insulated cable, rubber electrical cable |
size | 1.5-300mm2 |
Sheath | Chloroprene Rubber |
Voltage | 450/750V |
standard | IEC 60502-2,IEC 60228 |
insulation | CPE(Chlorinated Polyethylene) |
Brand Name | DONGJIAXIN |
Model Number | H07RN-F YC YCW, H05RN-F |
Certification | ISO,CE,IEC,TUV,KEMA |
Place of Origin | CHINA |
View Detail Information
Explore similar products
0.6/1kV 4 Core 26 gauge electrical wire , IEC 60502-1 pvc copper cable
N2XY YJV22 4 Core Xlpe Armored Power Cable , Low Voltage 10 Gauge 4 Wire Cable
AWM 2836 Parallel Industrial Electrical Cable Extruded Integral Insulation Hook
AWG UL2464 18AWG Industrial Electrical Cable , Mechanical Machine 2.5 Mm House
Product Specification
Payment Terms | L/C, T/T,, Western Union, MoneyGram | Supply Ability | 100KM/Week |
Delivery Time | 7-15 working days | Packaging Details | wooden drums according to quantity and container or required |
Model name | H07RN-F YC YCW, H05RN-F | Conductor Type | Flexible Copper (claass5) |
High light | rubber insulated cable, rubber electrical cable | size | 1.5-300mm2 |
Sheath | Chloroprene Rubber | Voltage | 450/750V |
standard | IEC 60502-2,IEC 60228 | insulation | CPE(Chlorinated Polyethylene) |
Brand Name | DONGJIAXIN | Model Number | H07RN-F YC YCW, H05RN-F |
Certification | ISO,CE,IEC,TUV,KEMA | Place of Origin | CHINA |
High Light | 750V Industrial Electrical Cable ,h05rnf cable ,CPE rubber insulated wire |
450/750V Copper Conductor Rubber Insulated Rubber Jacket 1~6mm² Ordinary Duty Cable
Working temperature:
H07RN-F model rated voltage U0/U IS 450/750V
H05RN-F model rated voltage U0/U IS 300/500V
H05RR-F model rated voltage U0/U IS 300/500V
Long time allow working temperature of wire core cant be higher than 60
Characteristic:
1. The long-term working temperature of conductor should be no longer than 65°C
2. W type cables have weather-proof character and certain grease-proof character and are suitable for outdoor usage and the occasion with greasy dirt.
3. ZR type cables have fire-retardant character.
Specification:
H05RN-F:
NO. | Cross section of conductor(mm²) | Conductor structure | Insulation thickness(mm) | sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
1 | 2×0.75 | 24/0.19 | 0.6 | 0.8 | 6.2±0.2 | 26.0 |
2 | 2×1 | 32/0.19 | 0.6 | 0.9 | 6.8±0.2 | 19.5 |
3 | 3×0.75 | 24/0.19 | 0.6 | 0.9 | 6.8±0.2 | 26.0 |
4 | 3×1 | 32/0.19 | 0.6 | 0.9 | 7.2±0.2 | 19.5 |
5 | 4×0.75 | 24/0.19 | 0.6 | 0.9 | 7.4±0.2 | 26.0 |
6 | 4×1 | 32/0.19 | 0.6 | 0.9 | 7.9±0.2 | 19.5 |
H07RN-F:
Cross section of conductor(mm²) | Conductor structure | Insulation thickness(mm) | sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
2×1 | 32/0.19 | 0.8 | 1.3 | 8.4±0.2 | 19.5 |
2×1.5 | 30/0.24 | 0.8 | 1.5 | 9.3±0.2 | 13.3 |
2×2.5 | 49/0.24 | 0.9 | 1.7 | 11.0±0.2 | 7.98 |
2×4 | 56/0.29 | 1.0 | 1.8 | 12.8±0.2 | 4.95 |
2×6 | 84/0.29 | 1.0 | 2.0 | 14.4±0.2 | 3.30 |
3×1 | 32/0.19 | 0.8 | 1.4 | 9.0±0.2 | 19.5 |
3×1.5 | 30/0.24 | 0.8 | 1.6 | 10.0±0.2 | 13.3 |
3×2.5 | 49/0.24 | 0.9 | 1.8 | 11.8±0.2 | 7.98 |
3×4 | 56/0.29 | 1.0 | 1.9 | 13.7±0.2 | 4.95 |
3×6 | 84/0.29 | 1.0 | 2.1 | 15.4±0.2 | 3.30 |
4×1 | 32/0.19 | 0.8 | 1.5 | 10.0±0.2 | 19.5 |
4×1.5 | 30/0.24 | 0.8 | 1.7 | 11.0±0.2 | 13.3 |
4×2.5 | 49/0.24 | 0.9 | 1.9 | 13.0±0.2 | 7.98 |
4×4 | 56/0.29 | 1.0 | 2.0 | 15.1±0.2 | 4.95 |
4×6 | 84/0.29 | 1.0 | 2.3 | 17.2±0.2 | 3.30 |
5×1 | 32/0.19 | 0.8 | 1.6 | 11.0±0.2 | 19.5 |
5×1.5 | 30/0.24 | 0.8 | 1.8 | 12.1±0.2 | 13.3 |
5×2.5 | 49/0.24 | 0.9 | 2.0 | 14.3±0.2 | 7.98 |
5×4 | 56/0.29 | 1.0 | 2.2 | 16.8±0.2 | 4.95 |
5×6 | 84/0.29 | 1.0 | 2.5 | 19.0±0.2 | 3.30 |
Testing process
▼Ordering Options:
For prompt quotation / supplies please make sure your inquiries and your orders are securing the following data :
1 International or Special Standard. (Alternatively, the precise usage of the cable.)
2 Rated voltage.
3 Copper or Aluminium conductors.
4 Size of each conductor.
5 Insulation material : PVC XLPE or others.
6 Number and identification of conductors.
7 Other requirements.
8 Packing.
9 Required delivery time.
10 Required validity.
If this all seems a litle too technical for you, then why not get in touch with us.We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.
▼ Company information:
30 years of experience in R & D, production and sales of wire and cable.
Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.
Annual revenue is about 500 million US dollars.
CNAS laboratory, more than 100 testing reports.
Products are widely used in real estate, municipal, industrial support, mobile communications etc
Company Details
Business Type:
Manufacturer
Year Established:
1990
Total Annual:
230701800.00-307602400
Employee Number:
200~300
Ecer Certification:
Verified Supplier
DJX Cable was first founded in 1990 and formally registered in 2003 as Shenzhen Dongjiaxin Wire&Cable co.,ltd.. In 2017, DJX established a group company Shenzhen Finecredit Group Co.,ltd. and started a group operation model with 4 wholly-owned subsidiaries. Group manufacturing base is located in... DJX Cable was first founded in 1990 and formally registered in 2003 as Shenzhen Dongjiaxin Wire&Cable co.,ltd.. In 2017, DJX established a group company Shenzhen Finecredit Group Co.,ltd. and started a group operation model with 4 wholly-owned subsidiaries. Group manufacturing base is located in...
Get in touch with us