China Closed Type Industrial Water Cooling Towers 1000000 Kcal/H Cooling Capacity
China Closed Type Industrial Water Cooling Towers 1000000 Kcal/H Cooling Capacity

  1. China Closed Type Industrial Water Cooling Towers 1000000 Kcal/H Cooling Capacity
  2. China Closed Type Industrial Water Cooling Towers 1000000 Kcal/H Cooling Capacity
  3. China Closed Type Industrial Water Cooling Towers 1000000 Kcal/H Cooling Capacity

Closed Type Industrial Water Cooling Towers 1000000 Kcal/H Cooling Capacity

  1. MOQ: I UNIT
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T
Supply Ability 300 UNIT/MONTH
Delivery Time 48 DAYS
Packaging Details PALLET WITH FILM WRAPPING FOR CONTAINER OCEAN TRANSPORT
Inlet/Outlet DN (mm) 125
Cooling Capacity (Kcal/h) 1000000
Unit Heat Rejection (KW) 1162
Unit Airflow (m3/h) 25000*4
Spray Water Flow Rate (m3/h) 143
Unit Dimension L × W × H (mm) 5900*2340*3870
Brand Name YANYE /JIANGFAN
Model Number YCT ,YNT .CLA
Certification iso 9001 2008
Place of Origin SHANGHAI

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 300 UNIT/MONTH
Delivery Time 48 DAYS Packaging Details PALLET WITH FILM WRAPPING FOR CONTAINER OCEAN TRANSPORT
Inlet/Outlet DN (mm) 125 Cooling Capacity (Kcal/h) 1000000
Unit Heat Rejection (KW) 1162 Unit Airflow (m3/h) 25000*4
Spray Water Flow Rate (m3/h) 143 Unit Dimension L × W × H (mm) 5900*2340*3870
Brand Name YANYE /JIANGFAN Model Number YCT ,YNT .CLA
Certification iso 9001 2008 Place of Origin SHANGHAI
High Light induced draft crossflow cooling towerbac closed circuit cooling tower

industrial cooling tower, water cooling towers.closed cooling tower

 

 

YanYe cooling equipment is widely used in petrochemical, pharmaceutical, steel, automotive, foundry, nuclear power plants, power plants, glass manufacturing, IT factories, food and other fields, and air withered systems, induction furnace, continuous casting equipment, mold, glass melting furnace, air compressors, injection molding machines, welding equipment, painting equipment and other facilities, and to partners in various fields to provide professional technical support and services.

 
Description Closed Cooling Tower, Cross flow
Model KBL-22
Operating Conditions
Nominal Flow Rate (m3/h) 200
Inlet/Outlet DN (mm) 125
Water Makeup/Bleed-off DN(mm) 40
Cooling Capacity (Kcal/h) 1000000 Kcal/h
Unit Heat Rejection (KW) 1162 kw
Unit Fan Motor (KW) 2.2 kw*4
Unit Airflow (m3/h) 25000*4
Spray Pump’s Delivery Lift (m) 12.5
Spray Pump Power (KW) 7.5 kw
Spray Water Flow Rate (m3/h) 143 m3/h
Main Water Pump’S Delivery Lift (m) 45
Main Water Pump’S Power (KW) 30
Main Water pump’s Flow Rate (m3/h) 140
Operation Work pressure 0.15--0.45 Mpa
Unit Dimension L × W × H (mm) 5900*2340*3870
Shipping Weight (kg) 4950
 
Supply Scope
Main Machine Cooling Coil Spec.

High-quality seamless 316L SS Coils

∮=19mm δ=1.0mm

Header Pipe Galvanized steel with stainless liner
Flange Stainless Steel
Shell Upper Shell High-quality 316L steel plate
Water Basin High-quality 316L steel plate
Fan System Fan Motor grade: IP55; Insulation: F; Alum-alloy blades; Axial Flow
Water Eliminator Anti-corrosion PVC
Wind Louvre Anti-corrosion; Sun sheltering; drift elimination
Spray System Spray Pump Cast iron
Spray Pipe PVC
Spray Nozzles ABS basket nozzles of umbrella style
Spare Parts

Drainage valve 1 unit,

Pressure meter 1 unit,

Thermometer 1 unit;

Mechanical seal for pump 1 unit,

Hand tools 1 set;

Sealing tapes 1 set;

Counter flange 1 set;

Float bulb 1 unit;

Basin filter 1 unit;

Control Panel Temperature controller Standard
Spray Pump Control Standard
System Malfunction Alarm Standard
Basin Level Alarm Standard
Fan Control System Standard
Electrical Brandname (otherwise please specify)
Power Nature 380V/3P/50HZ (otherwise please specify)
Please specify if more complicated and special functions are required.
 
 
 
 
 
 
 
 
 
 
Advantages of Closed Circuit Cooling Tower (CCCT)
 
 
Personnel Health Protection
Open cooling water system is subject to water pollution and, as a result, the bacteria of miscellaneous sorts proliferate fast to become a grave threat to human health by dissipating the bacteria containing vapor. A popular disease from open water cooling system is legionnaire that endangers human life by causing pneumonia, which is especially true for people living & working in the buildings with central air conditioners. Closed circuit cooling tower has the largest proportion of cooling water circulating inside enclosed loop, thus is not subject to water pollution. The specially designed louvers not only reduce the limited spray water drift to minimum level, but also effectively stop outside sunlight and particles from entering the tower basin cultivating the growth of bacteria.
Tube Scaling Prevention
Most scaling & fouling problems are caused by impurities brought into cooling tubes by process cooling water, which will easily damage heat rejection equipment like melting furnaces, some cases of which involve personnel safety issues. For other equipments like central air conditioner, generators, compressors etc, scaling problems are one of the main reasons for lower operation efficiency and souring maintenance cost. Closed circuit cooling tower eliminates the scaling problems by running de-mineralized process water inside the closed circuit cooling coils so that scaling problem is reduced to the lowest level if not completely eradicated.
Energy Saving
Variable frequency control ( VFC) is an option for flexible adjustment of the number and speed of working cooling fans to ambient temperature changes, the data of which can be preset at a certain figure. During winter season, the spray water stops automatically when ambient temperature drops to a certain level using only a set number of operating fans to satisfy the reduced cooling requirements.
Water Saving
CCCT system adopts 100% closed circuit circulation for process fluid that saves water from loss in any form. Special baffle is used to reduce unavoidable spray water loss to the lowest point without negative impact on the cooling efficiency. The prominent water saving nature is one of the most important factors deciding the popular use of closed circuit cooling tower.
Space Saving
Closed circuit cooling tower is designed to operate within very limited space, accounting for 1/4-1/5 that of open cooling system, saving any form of ground construction. The effective drift eliminator baffle enables closed circuit cooling towers to be used indoors close to production line without wetting the groud.
Investment Saving
Closed circuit cooling tower has self-attached water basin and fully enclosed cooling coils for preservation of cooling water that saves any form of ground construction cost. Under open cooling tower system, the large water pool is a necessity to supply all process cooling water, and the related investment will be of no use if the open cooling tower is to be re-installed to a different site.
User Friendly
Yanye closed circuit cooling tower can be controlled via remote control panel with clearly defined functional push-buttons and digital display system. Automatic Light & Sound alarm system is installed to remind the operator of extreme working conditions of the cooling system for on time adjustment; VFC technology is available for automatic setting of the cooling tower operation data following ambient changes without human interference. Computer control system is also possible under highly sophisticated cooling system requirements.
Longer Life Expectancy
Instead of adopting wooden structure or PVC cooling fills, closed circuit cooling tower is composed of copper or carbon steel cooling coils, zink-aluminum galvanized steel case and stainless steel structures etc that prolongs the trouble-free service life of closed circuit cooling tower.
Easy Installation and Maintenance
The installation of closed circuit cooling tower includes merely the connection of piping and electrical system that can be done even by technical workers without training.
Due to the scaling-free nature of closed circuit cooling tower, a great deal of human efforts for monthly or quarterly maintenance can be saved, which are normally neglected due to the busy production schedule and tend to cause sudden stop with long accummulation of scalings.
Choosing closed circuit cooling tower comes to be part of our responsibility for protection of life and environment with safe & saving industrial cooling solutions

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company,Seller,Other

  • Year Established:

    2008

  • Total Annual:

    2000-4999

  • Employee Number:

    100~200

  • Ecer Certification:

    Active Member

Shanghai Yanye industrial Cooling Equipment Co., Ltd ( YANYE Cooling ) is a manufacturing plant for provision of various industrial & commercial cooling solutions. The system ranges from the cooling of water to gas, oil and miscellaneous industrial fluid mediums, with a strong emphasis on the ma... Shanghai Yanye industrial Cooling Equipment Co., Ltd ( YANYE Cooling ) is a manufacturing plant for provision of various industrial & commercial cooling solutions. The system ranges from the cooling of water to gas, oil and miscellaneous industrial fluid mediums, with a strong emphasis on the ma...

+ Read More

Get in touch with us

  • Reach Us
  • SHANGHAI YANYE INDUSTRIAL EQUIPMENT CO.,LTD
  • https://www.industrialwatercoolingtowers.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement