Henan Universe Intraocular Lens Research and Manufacture Co., Ltd.
Payment Terms | T/T |
Supply Ability | 10000 pcs per month |
Delivery Time | 30 days |
Material | Hydrophilic acrylate |
Size | 3.5mm |
Drainage Hole | 4 |
Body Thiness | 0.2mm |
Sterilization Method | Moist heat |
Shelf Life | 3 years |
Brand Name | Universe |
Model Number | FPT |
Certification | ISO13485, ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
3.5mmX3.0mm Glaucoma Drainage Device Implant ISO Aqueous Tube Shunt
Nonpenetrating Trabeculectomy Glaucoma Drainage Implant OEM ODM
CE Hydrophilic Acrylate Glaucoma Valve Implant 0.7mm Notch Width
ISO9001 0.2mm Thick Glaucoma Drainage Implant For Surgery
Product Specification
Payment Terms | T/T | Supply Ability | 10000 pcs per month |
Delivery Time | 30 days | Material | Hydrophilic acrylate |
Size | 3.5mm | Drainage Hole | 4 |
Body Thiness | 0.2mm | Sterilization Method | Moist heat |
Shelf Life | 3 years | Brand Name | Universe |
Model Number | FPT | Certification | ISO13485, ISO9001 |
Place of Origin | China | ||
High Light | Penetrating Trabeculectomy Glaucoma Drainage Implant ,Glaucoma Drainage Implant 3.5mm ,ISO13485 glaucoma drainage device |
Implantable Glaucoma Devices for Penetrating Trabeculectory
Glaucoma is a progressive optic neuropathy that is the second leading cause of preventable blindness worldwide, after cataract formation. A rise in the intraocular pressure (IOP) is considered to be a major risk factor for glaucoma and is associated with an abnormal increase of resistance to aqueous humour outflow from the anterior chamber. Implantable Glaucoma Devices have been developed to provide an alternative pathway through which aqueous humour can effectively exit the anterior chamber, thereby reducing IOP.
Implantable Glaucoma Devices for Penetrating Trabeculectomy Material
Glaucoma Value Model FPT for Glaucoma Surgery is produced biomaterial ethoxyl methacrylate ester/methyl methacrylate copolymer(2-HEMA-co-NMA) which is nontoxic, has no immune response, has good biological compatibility, and cannot be absorbed by tissue. As materials of intraocular lens, it has been clinically applied in ophthalmology for more than ten years, and is universally accepted as good intraocular implantation material by ophthalmology circle.
Implantable Glaucoma Devices for Penetrating Trabeculectomy Material Structure and Working Mechanism
Glaucoma Valve Model FPT for Glaucoma Surgery has four holes. Used for fixation on sclerotic bed and osmosis of aqueous humor, implant the Glaucoma Valve Model FPT for Glaucoma Surgery into resected deep sclerotic bed to form acavity which is called aqueous humor pond or depressurizing room, the upper bottom of linguiform one is exposed to the outside of sclerotic valve, that is made for aqueous humor being drained from the pond, cavity to the underside of conjunctiva, and promoting the formation of new aqueous humor channel, and thus to acheive the goal of reducing intraocular pressure.
Characteristics of Implantable Glaucoma Devices for Penetrating Trabeculectomy
1.Raw material: Hydrophilic acrylate. .
2.Which has good biological compatibility, and cannot be absorbed by tissue. .
3. Prohibit the growth of fibrocyte, and prevent the formation of filter channel cicatricle. .
4. To impel the formation of new aqueous humor drainage channel. .
5. Distributary of aqueous humor is formed after the implantation of drainage device.
6. It is safe for long-term usage, and intraocular pressure can be effectively controlled. .
7. To increase the success rate and reliability of Glaucoma operation.
Company Details
Business Type:
Manufacturer
Year Established:
1991
Total Annual:
10000000-15000000
Employee Number:
130~150
Ecer Certification:
Verified Supplier
Henan Universe Intraocular Lens Research and Manufacture Co., Ltd. was founded in 1991, is one of the first enterprises in China to produce intraocular lenses and related products. It has introduced advanced American technology and established a complete automated production line, integrating R... Henan Universe Intraocular Lens Research and Manufacture Co., Ltd. was founded in 1991, is one of the first enterprises in China to produce intraocular lenses and related products. It has introduced advanced American technology and established a complete automated production line, integrating R...
Get in touch with us
Leave a Message, we will call you back quickly!