China Cat5e SFTP 24AWG Extend To 350MHz 1000FT Solid Network PVC PE Cable
China Cat5e SFTP 24AWG Extend To 350MHz 1000FT Solid Network PVC PE Cable

  1. China Cat5e SFTP 24AWG Extend To 350MHz 1000FT Solid Network PVC PE Cable
  2. China Cat5e SFTP 24AWG Extend To 350MHz 1000FT Solid Network PVC PE Cable
  3. China Cat5e SFTP 24AWG Extend To 350MHz 1000FT Solid Network PVC PE Cable

Cat5e SFTP 24AWG Extend To 350MHz 1000FT Solid Network PVC PE Cable

  1. MOQ: 1000pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T
Supply Ability 2000pcs/day
Packaging Details Color Box+Packing Box 38*38*24cm
Delivery Time 15-45Days
Data Transfer Rate 100 Mbps
Length 1000 ft
Jacket Material PVC/PE
Frequency 100 MHz
Cable Type SFTP
Conductor Size 24 AWG
Certifications UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
Conductor aMaterial Bare Copper
Brand Name ITI-LINK
Model Number ITI-CT5SF-002
Certification UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
Place of Origin SHENZHEN

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 2000pcs/day
Packaging Details Color Box+Packing Box 38*38*24cm Delivery Time 15-45Days
Data Transfer Rate 100 Mbps Length 1000 ft
Jacket Material PVC/PE Frequency 100 MHz
Cable Type SFTP Conductor Size 24 AWG
Certifications UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS Conductor aMaterial Bare Copper
Brand Name ITI-LINK Model Number ITI-CT5SF-002
Certification UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS Place of Origin SHENZHEN
High Light 24AWG pe pvc cable350MHz pe pvc cable1000FT cat5e sftp

Cat5e SFTP 24AWG Extend To 350MHz Solid PVC PE High Speed Network Cable 1000FT

 

Description:

 

1. It provides a bandwidth of 100MHz within a distance of 90 meters. The typical application rate is 100Mbps.

 

 

2. This product is applied to shielded confidential systems with extremely high requirements for electromagnetic interference. It is used for indoor horizontal work area wiring and indoor local area network wiring.

 

 

3. The product selects high-quality oxygen-free copper as the transmission conductor. The electrical transmission performance is reliable and excellent, reaching and far exceeding the Category 5e system indicators.

 

 

4. On the outside of the four pairs of twisted-pair wires, a single-sided aluminum foil with a thickness of 0.06mm is longitudinally wrapped as a whole, and a tinned copper wire braided shielding layer is added. Compared with unshielded cables, on the premise of ensuring the same transmission bandwidth level, the anti-shielding interference ability of SFTP shielded cables is increased by 25dB and can reach 90dB. It can be used in environments with extremely high requirements for anti-electromagnetic interference. The overall shielding system has extremely high signal shielding and confidentiality.

 

 

· Bare solid copper conductor

· 100MHz

· RoHs/REAC Complied PVC/PE Jacket

· Rate temperature:60℃ 75℃

· InstallationTemperature: -30℃-+50℃

· CompliestoANSI/TIA-568-B.2&IS0/EC11801

· CE, RoHS, TUV, UL compliant, CPR, ETL, RCM, ISO9001

 

 

Product Description:

 

Cat 5e SFTP 4 X 2 X 24AWG  
Rev.: A ECN Description:  
Construction Item Description Electrical Property  

 

Conductor

 

Material

Bare Solid Copper(elongation:

19 ~ 24%)

Conductor Resistance at 20°C ≤ 9.5 Ω / 100m  
OD 24 AWG Resistance unbalance within a pair ≤ 2%  

 

 

 

 

 

Insulation

 

Material

 

HDPE 8303

Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

 

>1500 MΩ / 100m

 
OD 0.90 ± 0.02 mm Mutual capacitance 5600 pF / 100m MAX  
Average THK 0.20 mm Capacitance unbalance pair to ground at 800Hz or 1 kHz ≤ 160 pF / 100m  

 

 

 

Color

1p: white + 2 blue stripes & blue Characteristic impedance at 100MHz 100 ± 15 Ω  
2p: white + 2 orange stripes & orange

Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or

0.7 KV AC for 1 min

 

No breakdown

 
3p: white + 2 green stripes & green Mechanical Property  
4p: white + 2 brown stripes & brown

 

 

insulation

elongation before aging ≥ 300%  

 

 

Pair Twist

 

 

Lay & Direction

1p: S=20.0 mm (28%) tensile strength before aging ≥12 MPa  
2p: S=17.5 mm (24%)) elongation after aging ≥ 150 %  
3p: S=22.0 mm (32%) tensile strength after aging ≥10.5 MPa  
4p: S=15.5 mm (21%)

 

 

jacket

elongation before aging ≥ 150 %  
OD / tensile strength before aging ≥ 13.5 MPa  

 

Inner Assemble

Lay S=90 ± 5 mm elongation after aging ≥ 125 %  
Direction according to the drawing tensile strength after aging ≥ 12.5 MPa  
Filler / Packing  
OD / Drum NA  
Filler Ripcord 300D Master Carton NA  
Drain Wire Tinned Copper

 

 

 

 

Outside Shield

Shield Shield  
Construction /  
Material Polyester film/Aluminium Foil (PET/ALU)  
Coverage ≥ 115%  

 

 

 

 

Jacket

Material PVC, 50P, -20~75℃  
Hardness 81 ± 3  
OD 6.5 ± 0.2  
Average THK 0.50 ~ 0.60  

 

Color

according to the customer's requirements  
Marking Color

according to the customer's

requirements

 
Marking

according to the customer's

requirements

 

 

 

Electrical Properties
Conductor Resistance at 20°C NF EN 50289-1-2 / IEC 60189-1 ≤ 9.5 Ω / 100m
Resistance unbalance within a pair NF EN 50289-1-2/ IEC 60708 ≤ 2%

Dielectric Strength

Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min

 

 

NF EN 50289-1-3 / IEC 61196-1-105

 

 

No breakdown

Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

 

NF EN 50289-1-4 / IEC 60885-1

 

>1500 MΩ / 100m

Mutual capacitance NF EN 50289-1-5 /IEC 60189-1 5600pF / 100m MAX
Capacitance unbalance pair to ground at 800Hz or 1 kHz NF EN 50289-1-5 / IEC 60189-1 ≤ 160 pF / 100m
Characteristic impedance at 100MHz NF EN 50289-1-11/ IEC 61156-1 100 ± 15 Ω
Spark Test UL444 2000 ± 250VOC

 

 

Transmission Properties
CAT5e ANSI/TIA-568.2-D; IEC 61156-6; YD/T1019-2013

 

 

No.

 

Frequency

 

Attenuation (Max)

Propagation Delay

(MAX)

Propagation Delay Skew

(MAX)

 

Return Loss (Min)

 

NEXT (Min)

 

PS NEXT (Min)

 

EL-FEXT (Min)

 

PS EL-FEXT (Min)

MHz dB/100m ns/100m ns/100m dB(on 100m) dB(on 100m) dB(on 100m) dB(on 100m) dB(on 100m)
1 4 4.05 552 45 23.01 56.27 53.27 51.96 48.96
2 8 5.77 546.73 45 24.52 51.75 48.75 45.94 42.94
3 10 6.47 545.38 45 25 50.3 47.3 44 41
4 16 8.25 543 45 25 47.24 44.24 39.92 36.92
5 20 9.27 542.05 45 25 45.78 42.78 37.98 34.98
6 25 10.42 541.2 45 24.32 44.33 41.33 36.04 33.04
7 31.25 11.72 540.44 45 23.64 42.88 39.88 34.1 31.1
8 50 15.07 539.09 45 22.21 39.82 36.82 30.02 27.02
9 62.5 16.99 538.55 45 21.54 38.36 35.36 28.08 25.08
10 100 21.98 537.6 45 20.11 35.3 32.3 24 21
11                  
12                  
13                  
14                  
Remarks: * are the reference values

 

 

 

Notices:

 

1. Open the packaging, check the products carefully, and take them gently.

2. Please strictly follow the wiring standards during construction, and do not tie or excessively bend the network cables.

3. When making RJ45 network cable connectors, please follow the T568B or T568A standards to ensure the correct wire sequence and avoid problems such as disconnected lines or unstable network connections.

4.It is best to use a single network cable at a distance of no more than 100 meters to ensure optimal transmission performance.

5. Ensure that the shielded network cable is grounded during installation.

 

 

Applications:

 

Cat5e SFTP network cable, as a high-performance network transmission medium, is widely used in various scenarios that require extremely high data transmission speed, stability, and anti-interference ability. Its unique dual shielding design - including one layer of aluminum foil shielding and one layer of woven mesh shielding - effectively isolates electromagnetic interference (EMI) and radio frequency interference (RFI) from the external environment, ensuring the purity and integrity of data transmission.

 

1. Enterprise level data centers and server rooms

2. Industrial Ethernet applications

3. Security monitoring system

4. Smart Home and Building Automation

5. Audio and video transmission

 

In summary, the Cat5e SFTP network cable, with its excellent performance and wide application adaptability, has become an indispensable component in many fields such as modern network communication, industrial automation, security monitoring, and smart homes, providing a solid foundation for building efficient and stable network communication systems.

 

 

 

 

 

FAQ

UL/CE/RoHS/ETL/CPR Certificate Shielded Lan cable Cat5e SFTP 24AWG Extend To 350MHz PVC/PE Bare Solid Copper

 

Q1. Can I order samples of Lan cables?

A: Yes, we welcome sample order to test and check quality.

 

Q2. What about the lead time?

A: 3-5 days for Sample preparing ,8-10 working days for mass production.

 

Q3. Do you have a minimum order quantity limit for network cable orders?

A: Low MOQ, 1pc for sample checking is available.

 

Q4. How do you ship the goods and how long does it take to arrive?

A: We usually ship by sea, which usually takes about 7 days to arrive.

 

Q5. How to proceed an order for network cable?

A: Firstly let us know your requirements or application.

Secondly We quote according to your requirements or our suggestions.

Thirdly customer confirms the samples and places deposit for formal order.

Fourthly We arrange the production.

 

Q6.Is it OK to print my logo on network cable product?

A: Yes. Please inform us formally before our production.

 

Q7: Do you offer guarantee for the products?

A: Yes, we offer 10 years warranty to our products.

 

Q8: How to deal with the faulty?

A: Firstly, Our products are produced in strict quality control system and the defective rate will be less than 0.2%.

 

Secondly, for individual defective products, we will remedy them as soon as possible and send them to you, or we can discuss solutions based on the actual situation to achieve 100% satisfaction for you.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Seller

  • Year Established:

    2014

  • Total Annual:

    100,000,000-150,000,000

  • Employee Number:

    100~200

  • Ecer Certification:

    Verified Supplier

New Service: Integrity Cable Co., Limited has an extremely professional and innovative service team. All of its members possess profound industry knowledge and rich practical experience. They are capable of customizing personalized technological solutions according to your specific requirements a... New Service: Integrity Cable Co., Limited has an extremely professional and innovative service team. All of its members possess profound industry knowledge and rich practical experience. They are capable of customizing personalized technological solutions according to your specific requirements a...

+ Read More

Get in touch with us

  • Reach Us
  • Integrity Cable Co., Limited
  • Building B,C,H,I. No.30, The Third Industrial Area, Xiacun,No.102 Matian North Road, Gongming Office, Guangming New District, Shenzhen
  • https://www.iti-cable.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement