Payment Terms | T/T |
Supply Ability | 2000pcs/day |
Delivery Time | 15-45 Days |
Packaging Details | Wooden shaft packaging 32*22*12cm Outer box size: 37*37*24cm |
Cable Type | SFTP |
Conductor Material | Copper |
Color | Orange |
Category | CAT7A |
Frequency | 1000 MHz |
Cable Length | 305 Meters |
Conductor Size | 23 AWG |
Jacket Material | PVC |
Brand Name | ITI-LINK |
Model Number | ITI-CTSF7A-006 |
Place of Origin | SHENZHEN |
Certification | UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS |
View Detail Information
Explore similar products
23AWG SFTP CAT7A Cable Orange LSZH Ethernet Cable With 100% Copper 10Gbps 1000FT
SFTP CAT7A High Speed Ethernet Cable with PVC Jacket Shielded EMI/RFI Protection
CAT7A SFTP Ethernet Cable Shielded EMI/RFI 1000MHz Bandwidth PVC Jacket for Data
SFTP CAT7A LSZH Ethernet Cable 1000MHz 23AWG Blue Cable for Industrial &Data
Product Specification
Payment Terms | T/T | Supply Ability | 2000pcs/day |
Delivery Time | 15-45 Days | Packaging Details | Wooden shaft packaging 32*22*12cm Outer box size: 37*37*24cm |
Cable Type | SFTP | Conductor Material | Copper |
Color | Orange | Category | CAT7A |
Frequency | 1000 MHz | Cable Length | 305 Meters |
Conductor Size | 23 AWG | Jacket Material | PVC |
Brand Name | ITI-LINK | Model Number | ITI-CTSF7A-006 |
Place of Origin | SHENZHEN | Certification | UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS |
High Light | 23AWG SFTP CAT7A Cable ,1000MHz SFTP CAT7A Cable ,10Gbps SFTP CAT7A Cable |
Cat7A SFTP Shielded Ethernet Cable 1000MHz 10Gbps, 23AWG Pure Copper for Data Center
Product Description:
1.The Cat7A SFTP Shielded Ethernet Orange Cable is a top - notch networking solution tailored for the rigorous demands of data centers. With a 23 AWG conductor size, this cable is engineered to offer outstanding performance and unwavering reliability during high - speed data transfer.
2.Measuring 305 meters in length, this orange - hued cable provides extensive flexibility for installation within large - scale data center environments. Whether it's for connecting servers, storage devices, or networking switches, the ample length ensures seamless connectivity, meeting all your data center's cabling requirements.
3.Operating at an impressive 1000 MHz frequency and boasting a 10Gbps data transfer rate, the Cat7A SFTP Shielded Ethernet Orange Cable guarantees swift data transmission with minimal interference. This makes it an ideal fit for data centers where reliable and ultra - fast data transfer is the lifeblood of operations.
4.The cable is encased in a durable PVC jacket. PVC offers excellent protection against physical damage, abrasion, and moisture, ensuring the cable's longevity even in the harsh conditions often found in data centers. It also provides flexibility, facilitating easy installation around racks and through conduits.
5.Constructed using pure copper conductors, this cable offers superior conductivity and signal quality. Copper, being highly conductive, enables efficient data transfer while minimizing signal loss, which is crucial for maintaining high - performance networking within the data center.
6.Overall, this Cat7A SFTP Shielded Ethernet Orange Cable, also recognized as a Cat7A Ethernet Cable or CAT7 LAN Cable, serves as a reliable and high - speed networking solution specifically designed for data centers. Its robust build, high - frequency capabilities, and use of quality materials like pure copper and PVC make it well - equipped to handle the most demanding networking requirements of modern - day data centers.
Technical Parameters:
Jacket Material | PVC |
Category | CAT7A |
Cable Type | SFTP |
Cable Length | 305 Meters |
Conductor Material | Copper |
Color | Orange |
Conductor Size | 23 AWG |
Frequency | 1000 MHz |
Product Description: Cat7A SFTP Shielded Ethernet Cable 1000MHz 10Gbps, 23AWG Pure Copper for Data Center | ||||||
Rev.: A | ECN Description: | |||||
Construction Item Description | Electrical Property | |||||
Conductor |
Material | Bare Solid Copper(elongation: 19-24%) | Conductor Resistance at 20°C | ≤ 9.5 Ω / 100m | ||
OD | 23AWG | Resistance unbalance within a pair | ≤ 2% | |||
Insulation | Material | PE Skin-Foam-Skin | Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V |
>1500 MΩ / 100m | ||
OD | 1.45 ±0.01 mm | Mutual capacitance | 5600 pF / 100m MAX | |||
Average THK | 0.42 mm | Capacitance unbalance pair to ground at 800Hz or 1 kHz | ≤ 160 pF / 100m | |||
Color | 1p: white + 2 blue stripes & blue | Characteristic impedance at 100MHz | 100 ± 15 Ω | |||
2p: white + 2 orange stripes & orange | Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or 0.7 KV AC for 1 min |
No breakdown | ||||
3p: white + 2 green stripes & green | Mechanical Property | |||||
4p: white + 2 brown stripes & brown |
insulation | elongation before aging | ≥ 300% | |||
Pair Twist |
Lay & Direction | 1p: S=19.0 mm (28%) | tensile strength before aging | ≥12 MPa | ||
2p: S=23.5 mm (31%) | elongation after aging | ≥ 150 % | ||||
3p: S=21.5 mm (33%) | tensile strength after aging | ≥10.5 MPa | ||||
4p: S=25.0 mm (36%) |
jacket | elongation before aging | ≥ 150 % | |||
OD | / | tensile strength before aging | ≥ 13.5 MPa | |||
Inner Assemble | Lay | S=90 ± 5 mm | elongation after aging | ≥ 125 % | ||
Direction | according to the drawing | tensile strength after aging | ≥ 12.5 MPa | |||
OD | / | Packing | ||||
Filler | Ripcord | / | Drum | NA | ||
Drain Wire | / | |||||
Pair Shield | Shield | Pair Shield | ||||
Construction | / | |||||
Material | Polyester/Aluminium (PET/ALU) | |||||
Coverage | ≥ 115% | |||||
Braid | Material | ɸ 0.12mm Aluminum-magnesium braidedr | ||||
Coverage | ≥ 40% | |||||
Jacket | Material | PVC, 50P, -20~75℃ | ||||
Hardness | 81± 3 | |||||
OD | 8.5 ± 0.2 | |||||
Average THK | 0.60 ~ 0.70 | |||||
Color | according to the customer's requirements | |||||
Marking Color | Orange | |||||
Marking | according to the customer's requirements |
Transmission Properties | |||||||||
CAT7A ANSI/TIA-568.2-D; IEC 61156-6; YD/T1019-2013 | |||||||||
No. |
Frequency |
Attenuation (Max) | Propagation Delay (Max) | Propagation Delay Skew (Max) |
Return Loss (Min) |
NEXT (Min) |
PS NEXT (Min) |
EL-FEXT (Min) |
PS EL-FEXT (Min) |
MHz | dB/100m | ns/100m | ns/100m | dB(on 100m) | dB(on 100m) | dB(on 100m) | dB(on 100m) | dB(on 100m) | |
1 | 4 | 3.7 | 552 | 25 | 23.0 | 78.0 | 75.0 | 78.0 | 75.0 |
2 | 8 | 5.2 | 547 | 25 | 24.5 | 78.0 | 75.0 | 77.2 | 74.2 |
3 | 10 | 5.8 | 545 | 25 | 25.0 | 78.0 | 75.0 | 75.3 | 72.3 |
4 | 16 | 7.3 | 543 | 25 | 25.0 | 78.0 | 75.0 | 71.2 | 68.2 |
5 | 20 | 8.2 | 542 | 25 | 25.0 | 78.0 | 75.0 | 69.3 | 66.3 |
6 | 25 | 9.2 | 541 | 25 | 24.3 | 78.0 | 75.0 | 67.3 | 64.3 |
7 | 31.25 | 10.3 | 540 | 25 | 23.6 | 78.0 | 75.0 | 65.4 | 62.4 |
8 | 62.5 | 14.6 | 539 | 25 | 21.5 | 78.0 | 75.0 | 59.4 | 56.4 |
9 | 100 | 18.5 | 538 | 25 | 20.1 | 75.4 | 72.4 | 55.3 | 52.3 |
10 | 200 | 26.5 | 537 | 25 | 18.0 | 70.9 | 67.9 | 49.3 | 46.3 |
11 | 250 | 29.7 | 536 | 25 | 17.3 | 69.4 | 66.4 | 47.3 | 44.3 |
12 | 300 | 32.7 | 536 | 25 | 17.3 | 68.2 | 65.2 | 45.8 | 42.8 |
13 | 400 | 38.0 | 536 | 25 | 17.3 | 66.4 | 63.4 | 43.3 | 40.3 |
14 | 500 | 42.8 | 536 | 25 | 17.3 | 64.9 | 61.9 | 41.3 | 38.3 |
15 | 600 | 47.1 | 535 | 25 | 17.3 | 63.7 | 60.7 | 39.7 | 36.7 |
16 | 1000 | 61.9 | 535 | 25 | 15.1 | 60.4 | 57.4 | 35.3 | 32.3 |
Electrical Properties | ||
Conductor Resistance at 20°C | NF EN 50289-1-2 / IEC 60189-1 | ≤ 9.5 Ω / 100m |
Resistance unbalance within a pair | NF EN 50289-1-2/ IEC 60708 | ≤ 2% |
Dielectric Strength Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min |
NF EN 50289-1-3 / IEC 61196-1-105 |
No breakdown |
Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V |
NF EN 50289-1-4 / IEC 60885-1 | >1500 MΩ / 100m |
Mutual capacitance | NF EN 50289-1-5 /IEC 60189-1 | 5600pF / 100m MAX |
Capacitance unbalance pair to ground at 800Hz or 1 kHz | NF EN 50289-1-5 / IEC 60189-1 | ≤ 160 pF / 100m |
Characteristic impedance at 100MHz | NF EN 50289-1-11/ IEC 61156-1 | 100 ± 15 Ω |
Spark Test | UL444 | 2000 ± 250VOC |
Applications:
1.The Cat7A SFTP Shielded Ethernet Orange Cable is a premium - grade Ethernet cable specifically engineered for the intricate demands of data center networking applications. With its Cat7A classification, this cable offers unparalleled performance and unwavering reliability in the most challenging networking environments.
2.One of the primary application scenarios for the [Brand Name] Cat7A cable is in high - speed data transfer within data centers, where a stable and ultra - fast connection is of utmost importance. Whether it's for interconnecting servers, storage arrays, or high - performance switches in a data center, this cable guarantees seamless data transmission with minimal interference, enabling the efficient operation of data - intensive applications.
3.The distinct orange color of the cable makes it highly visible and easy to identify within the complex wiring systems of a data center. This not only simplifies cable management but also adds a touch of uniqueness. The 23 AWG pure copper conductors inside the cable are designed to ensure rapid and efficient data flow, maintaining high signal integrity. This makes it an ideal choice for Cat7A Lan Cable installations in data centers, where the quality of data transmission directly impacts business operations.
4.Manufactured with precision, the Cat7A cable is crafted to meet the strictest quality standards. It features a durable PVC jacket that not only protects the internal components from physical damage but also provides resistance to environmental factors commonly found in data centers, such as dust and moisture. Its SFTP design offers enhanced shielding, effectively minimizing crosstalk and external interference. This ensures a stable and secure connection, even in the presence of high - level electromagnetic noise that is typical in data center environments.
5.Whether you are in the process of upgrading your existing data center network infrastructure to handle the increasing demands of big data and cloud computing or setting up a new state - of - the - art data center from the ground up, the [Brand Name] Cat7A SFTP Shielded Ethernet Orange Cable is a versatile and reliable solution. It offers superior performance and long - term durability, making it a trusted choice for all your Cat7A Ethernet Cable requirements in data center networking. Experience seamless and high - speed networking connectivity with this exceptional cable.
FAQ:
Q: What is the brand name of this SFTP CAT7A Cable?
A: The brand name of this cable is ITI-LINK.
Q: What is the model number of this SFTP CAT7A Cable?
A: The model number of this cable is ITI-CTSF7A-006.
Q: Where is this SFTP CAT7A Cable manufactured?
A: This cable is manufactured in SHENZHEN.
Q: What type of shielding does this SFTP CAT7A Cable have?
A: This cable has SFTP (Screened Foiled Twisted Pair) shielding for enhanced performance.
Q: What is the length of this SFTP CAT7A Cable?
A: This cable is 1000 feet (approximately 305 meters) in length.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2014
Total Annual:
100,000,000-150,000,000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
New Service: Integrity Cable Co., Limited has an extremely professional and innovative service team. All of its members possess profound industry knowledge and rich practical experience. They are capable of customizing personalized technological solutions according to your specific requirements a... New Service: Integrity Cable Co., Limited has an extremely professional and innovative service team. All of its members possess profound industry knowledge and rich practical experience. They are capable of customizing personalized technological solutions according to your specific requirements a...
Get in touch with us
Leave a Message, we will call you back quickly!