Delivery Time | 15 working days |
Payment Terms | T/T in advance ,L/C |
Supply Ability | 50 sets/ month |
Place of Origin | China |
Brand Name | Kingsine |
Certification | ISO9001,CE |
Model Number | KS908 |
View Detail Information
Explore similar products
KS908 Modbus RTU - Test
High Precision RTU-Test with AC / DC / Harmonic Standard KS901
Portable 220V 50Hz RTU - Tester KS908 for Transducer , Energy Meter
Product Specification
Delivery Time | 15 working days | Payment Terms | T/T in advance ,L/C |
Supply Ability | 50 sets/ month | Place of Origin | China |
Brand Name | Kingsine | Certification | ISO9001,CE |
Model Number | KS908 | ||
High Light | 220V ac rtu-tester ,KS908 rtu products ,25VA RTU-Test |
220V / 25VA RTU-Test
Built-in high precision AC/DC/Harmonic standard source output
Voltage Output Shift:100V/220/380V Auto switch
Current Output Shift:1A/5A/10A Auto switch
Technical Data of KS908
Voltage (AC) Output/Measure |
|
Shift |
100V/220/380V Auto switch |
Adjusting range |
0 ... 120% |
Min Adjusting Unit |
Shift x 0.01% |
Resolution |
Shift x 0.01% |
Accuracy |
0.05%RG (RG abbr. range) |
Stability |
0.01%/1min |
Current (AC) Output/Measure |
|
Shift |
1A/5A/10AAuto switch |
Adjusting range |
0 ... 120% |
Min Adjusting Unit |
Shift x 0.01% |
Resolution |
Shift x 0.01% |
Accuracy |
0.05%RG |
Stability |
0.01%/1min |
Power Output/Measure |
|
Min Adjusting Unit |
Shift x 0.01% |
Resolution |
Shift x 0.01% |
Accuracy |
0.05%RG (F>0.5) |
Stability |
0.01%/1min |
Frequency Output/Measure |
|
Range |
45.000...65.000Hz |
Min Adjusting Unit |
0.001Hz |
Accuracy |
0.01%RD |
Phase Output/Measure |
|
Range |
0.00° ... 359.99° |
Min Adjusting Unit |
0.01° |
Resolution |
0.01° |
Accuracy |
0.05° |
Power factor Output/Measure |
|
Output range |
-1 ... 0 ... +1 |
Min Adjusting Unit |
0.0001 |
Accuracy |
0.0005 |
Harmonic Output/Measure |
|
Set range |
2 ... 31 times |
Content |
Voltage, Current≤30%( compared with Fundamental Wave) |
Harmonic output accuracy |
0.1%(2 ... 19 times, compared with Fundamental Wave) |
Resolution |
0.2%(20 ... 31 times, compared with Fundamental Wave) |
Harmonic Phase |
0.00° ... 359.99° |
Output Voltage and Current distortion |
|
<0.2%(non capacitance load) |
|
Max AC Output Load |
|
Voltage 25VA, Current 25VA |
|
Voltage (DC) Output/Measure |
|
Shift |
100mV/1V/10V/30V/100V/300V |
Adjusting range |
0 ... 120%, 0 ... 110% at shift 750V |
Min Adjusting Unit |
Shift x 0.01% |
Resolution |
Shift x 0.01% |
Accuracy |
0.05%RG |
Stability |
0.01%/1min |
Current (DC) Output/Measure |
|
Shift |
1mA/10mA/20mA |
Adjusting range |
0 ... 120% |
Min Adjusting Unit |
Shift x 0.01% |
Resolution |
Shift x 0.01% |
Accuracy |
0.05%RG |
Stability |
0.01%/1min |
Max DC Output Load |
|
Voltage 20VA, Current 25VA |
|
DC measure |
|
Voltage measure range |
±10V |
Current measure range |
±20mA |
Accuracy |
0.01%RG |
Index measure reference condition |
|
Work temperature |
0°C ... 40°C |
Humidity range |
≤85 % |
Work power supply range |
220VAC±15%, 50Hz |
Weight |
18KG |
Dimensions |
450(D)×180 (W)×380 (H) mm |
Interface |
RJ45, USB, PS/2, RS232 |
Major functions:
KS901 | KS907 | KS908 | |
AC Standard Sources | ● | ● | ● |
DC Standard Sources | ● | ● | ● |
Power Standard Sources | ● | ● | ● |
Harmonic Standard Sources | ● | ● | ● |
Indicator Test | ● | ○ | ● |
Transmitter Test | ● | ● | ● |
Energy Meter Test | ● | ● | ● |
Rtu Test | ● | ● | ● |
Standard Meter | ○ | ○ | ● |
Sychronization test | ● | ● | |
Tele-control, tele-communication | ● | ● |
Note: ● :With the corresponding function modules
○ : Without the corresponding function modules
● Built-in high precision AC/DC/Harmonic standard source output;
● User-friendly interface comes by the use of Windows CE operating system kernel;
● Functions available such as calibration of AC sampling, transducer, and energy meter; auto-compute on the calibration error and follow-up report creating; report template can be defined by the users;
● Mouse and keyboard built in panel or external connection available;
● USB port convenient for data transmissio;
● Can be used as a standard meter to monitor the information of electric quantity of AC transmission line (available in KS905, KS906);
● Workable without PC, and provides RS232 and RJ45 to support PC communications. And the communication protocol is open to the users to make auto testing solution if necessary;
● Can be run offline, while providing network RJ45 port and RS232 port and PC communication, communication protocol and opening up to the user anduser-friendly program to test automatically;
● Compact size and portable carrying, convenient for on-site operation
Company Details
Business Type:
Manufacturer,Seller
Year Established:
1999
Total Annual:
5 MIllion-9 MIllion
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a... Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a...
Get in touch with us
Leave a Message, we will call you back quickly!