Payment Terms | D/A, D/P, T/T |
Supply Ability | 100/Day |
Delivery Time | 5-7 work day |
Packaging Details | Carton |
Type | IVD Diagnostic Reagent |
Dimensions | 378mm×380mm×510mm |
Test Speed | 90 Second Per Test |
Report Range | 3-18% |
Voltage | 100-240VA |
Frequency | 50/60Hz |
Brand Name | LABNOVATION |
Model Number | LD-560 |
Certification | IFCC, NGSP, CE |
Place of Origin | Shenzhen, China |
View Detail Information
Explore similar products
HbA1c Analyzer Fully Automated HbA1c Analyzer LD-600 (HPLC)
Human Blood Smart Auto Hematology Analyzer 9027809990
Whole Blood Prediluted Blood HbA1c Test Analyzer Hematology Instruments
90 Second 420nm HbA1c Test Analyzer Full Modular Hematology Equipment
Product Specification
Payment Terms | D/A, D/P, T/T | Supply Ability | 100/Day |
Delivery Time | 5-7 work day | Packaging Details | Carton |
Type | IVD Diagnostic Reagent | Dimensions | 378mm×380mm×510mm |
Test Speed | 90 Second Per Test | Report Range | 3-18% |
Voltage | 100-240VA | Frequency | 50/60Hz |
Brand Name | LABNOVATION | Model Number | LD-560 |
Certification | IFCC, NGSP, CE | Place of Origin | Shenzhen, China |
High Light | LD560 Fully Automatic HbA1c Test Analyzer ,LD560 HbA1c Test Analyzer ,LD560 HbA1c Test Analyzer IVD |
HbA1c Test Analyzer HPLC Method Hemoglobin Test LD-560 Fully Automatic HbA1c Detection Analyzer
Intended Use
Specifications
Name | Fully Automated HbA1c Analyzer |
Model | LD-560 |
Method | HPLC(High Performance Liquid Chromatography) |
Parameters | HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional) |
Test Speed | 90 seconds per test |
Wavelength | 420nm |
Sample Type | Whole Blood, Pre-diluted blood |
Autoloader Capacity | 20 tubes |
Precision | CV<2% |
Column Capacity | 3000 tests |
Working Condition | Temperature: 15-30℃ |
Net weight | 28kg |
Storage environment: Temperature | -20℃~55℃ |
Humidity | 10%~93% |
Principle
Feature
Advantage
Performance Parameters
Reporting unit: Glycosylated hemoglobin (HbA1c) is reported in NGSP (%) and IFCC units (mmol/mol).
Accuracy: The accuracy is tested with reference materials as samples, and the relative deviation of the test results should be within ±5%.
Stability Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested, and the relative deviation of the test results is not more than ±3.0%.
Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.
FAQ
Normally all our medical equipment are in stock, so we can deliver goods within 5 workdays after receipt payment.
We have professional engineers,they will solve your problem by communicating with skype or phone.
Our prices are competitive compared with those at the same quality level, and we keep striving to provide the best pricing to our customers.
Certificated
Company Details
Business Type:
Manufacturer
Year Established:
2001
Total Annual:
10000000-50000000
Employee Number:
100~600
Ecer Certification:
Active Member
Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent... Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent...
Get in touch with us
Leave a Message, we will call you back quickly!