China factories

China factory - Labnovation Technologies, Inc.

Labnovation Technologies, Inc.

  • China,Shenzhen
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry
China LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry

  1. China LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry
  2. China LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry

LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry

  1. MOQ: 1
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms D/A, D/P, T/T
Supply Ability 100/Day
Delivery Time 10 work day
Packaging Details Carton
Size 220mm*150mm*120mm
Weight 800g
Shelf Life 9 Months
Analytical wave-length 510nm and 580nm
Sample volume 4μl full-blood
Input power <60VA
Brand Name LABNOVATION
Model Number LD-100
Certification IFCC, NGSP, CE
Place of Origin Shenzhen, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms D/A, D/P, T/T Supply Ability 100/Day
Delivery Time 10 work day Packaging Details Carton
Size 220mm*150mm*120mm Weight 800g
Shelf Life 9 Months Analytical wave-length 510nm and 580nm
Sample volume 4μl full-blood Input power <60VA
Brand Name LABNOVATION Model Number LD-100
Certification IFCC, NGSP, CE Place of Origin Shenzhen, China
High Light LD100 automatic hematology analyzerLD100 POCT automatic hematology analyzerLD100 510nm automatic hematology analyzer

HbA1c Analyzer LD-100 Hemoglobin Testing Analyzer POCT One Step Detection Fast Testing Analyzer

Intended Use

  • It is intended for the determination of percent hemoglobin A1c (HbA1c) in human whole blood.
  • It is a semi-automatic instrument used to analyze glycated hemoglobin.
  • It can be used to detect of HbA1c in medical units at all levels.And it's very protable to carry, you can testing HbA1c anytime.
  • It has fully automatic system just need one step operation then the test will be start.

Specifications

Model LD-100
Sample Type Whole blood
Sample Volume 4ul
Test Time Less than 3 minutes
Data storage 7000
Method Fluorescent Immunoturbidimetry
Operating Type 1-Step Operation, Fully automatic system
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Voltage 12VDC-3.33A
Analytical wave-length 510nm and 580nm.
Certification NGSP, IFCC

 

 

PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • Easy to operate, One Step Testing
  • High Accuracy
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • Color touch screen
  • External printer (Blue-tooth)
  • USB Port, LIS Support
  • One analyzer for testing without extra instrument

 

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

 

Performance Parameters

  • Accuracy: Is tested with the reference material as samples and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.

 

Certificated

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2001

  • Total Annual:

    10000000-50000000

  • Employee Number:

    100~600

  • Ecer Certification:

    Active Member

Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent... Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent...

+ Read More

Get in touch with us

  • Reach Us
  • Labnovation Technologies, Inc.
  • 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
  • https://www.labnovationtest.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement