China 3 Min Whole Blood Hemoglobin A1c Testing Equipment
China 3 Min Whole Blood Hemoglobin A1c Testing Equipment

  1. China 3 Min Whole Blood Hemoglobin A1c Testing Equipment
  2. China 3 Min Whole Blood Hemoglobin A1c Testing Equipment

3 Min Whole Blood Hemoglobin A1c Testing Equipment

  1. MOQ: 1
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms D/A, D/P, T/T
Supply Ability 100/Day
Delivery Time 10 work day
Packaging Details Carton
Size 220mm*150mm*120mm
Weight 800g
Test Speed < 3 min
Shelf Life 9 Months
Operating Type One Step Operation
Method Borate Affinity
Brand Name LABNOVATION
Model Number LD-100
Certification IFCC, NGSP, CE
Place of Origin Shenzhen, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms D/A, D/P, T/T Supply Ability 100/Day
Delivery Time 10 work day Packaging Details Carton
Size 220mm*150mm*120mm Weight 800g
Test Speed < 3 min Shelf Life 9 Months
Operating Type One Step Operation Method Borate Affinity
Brand Name LABNOVATION Model Number LD-100
Certification IFCC, NGSP, CE Place of Origin Shenzhen, China
High Light 3 Min hemoglobin a1c testing equipmentNGSP hemoglobin a1c testing equipmentWhole Blood hba1c test equipment

HbA1c Test Analyzer Hemoglobin Detection Analysis LD-100 Poct HbA1c Fully Automatic Testing Analyzer

Intended Use

The instrument is LD-100(POCT) One-Step HbA1c Analyzer, it's intended for the percent determination of hemoglobin A1c (HbA1c) in human
whole blood. LD-100 HbAc Analyzer is composed of the systems of sample cup mixing, colorimetric detection and system control, result display which can fast testing Hemoglobin with less time. Because the LD-100 HbA1c Analyzer is small and light so it 's very protable and suitable for the detection of HbA1c in medical units at all levels.

Specifications

Model LD-100
Sample Type Whole blood
Sample Volume 4ul
Testing Time Within 3 minutes
Data storage 7000
Power connection Detachable power supply cord
System Compose Sample cup mixing, Colorimetric detection And System control, Result display
Device category: Fixed
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Voltage 12VDC-3.33A
Analytical wave-length 510nm and 580nm.
Certification NGSP, IFCC

 

 

PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • One-Step Testing,Fully Automatic System 
  • Protable and convenient, Testing Anytime , Anywhere
  • Fast test speed and High Accuracy within 3 min
  • Battery Integrated
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • Color touch screen just need to clik the screen and easy to read

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

 

Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English;  Abnormal alarm function.

 

Certificated

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2001

  • Total Annual:

    10000000-50000000

  • Employee Number:

    100~600

  • Ecer Certification:

    Active Member

Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent... Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent...

+ Read More

Get in touch with us

  • Reach Us
  • Labnovation Technologies, Inc.
  • 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
  • https://www.labnovationtest.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement