Payment Terms | D/A, D/P, T/T |
Supply Ability | 100/Day |
Delivery Time | 15-20 working days |
Packaging Details | Carton |
Name | Smart Auto Hematology HbA1c Analyzer POCT Glycosylated Hemoglobin Detechtion |
Sample Type | Whole blood |
Test Time | ≤2 Minutes |
Sample Volume | 4μL |
Test Range | 4%-15% |
Shelf life of test kit | 9 Months |
Brand Name | LABNOVATION |
Model Number | LD-100 |
Certification | IFCC, NGSP, CE |
Place of Origin | Shenzhen, China |
View Detail Information
Explore similar products
Whole Blood Hematology Analyzer One Step Opreation POCT HbA1c Analyser For
LD-100 Hematology Detection Analyzer Medical One Step Hemoglobin A1c Analyzer
POCT One Step HbA1c Testing Analyzer Whole Blood Hemoglobin Analyzer LD-100
Portable Compact POCT HbA1c Analyzer Battery Integrated One Step Operation
Product Specification
Payment Terms | D/A, D/P, T/T | Supply Ability | 100/Day |
Delivery Time | 15-20 working days | Packaging Details | Carton |
Name | Smart Auto Hematology HbA1c Analyzer POCT Glycosylated Hemoglobin Detechtion | Sample Type | Whole blood |
Test Time | ≤2 Minutes | Sample Volume | 4μL |
Test Range | 4%-15% | Shelf life of test kit | 9 Months |
Brand Name | LABNOVATION | Model Number | LD-100 |
Certification | IFCC, NGSP, CE | Place of Origin | Shenzhen, China |
High Light | Smart Auto POCT HbA1c Analyzer ,Hematology POCT HbA1c Analyzer |
Smart Auto Hematology HbA1c Analyzer POCT Glycosylated Hemoglobin Detechtion
Smart Auto Hematology HbA1c Analyzer POCT Glycosylated Hemoglobin Detechtion is intended for measuring glycoslated hemoglobin (HbA1c) in human blood.
According to the most recent IDF data, 537 million people—approximately 10% of all people aged 20-79 in the world—were living with diabetes as of 2021.
With the development of modern medicine, people pay more and more attention to their own health and the diagnosis and control of diabetes has become a hot topic. As we know, diabetes is a group of metabolic diseases characterized by hyperglycemia. Every Patient with diabetes is adviced to have their HbA1c tested for 2-4 times annually.
Specification
Model | LD-100 |
Method | Boronate Affinity |
Measurement Time | ≤2 minutes |
Sample Type | Whole blood |
Measurement Range | 4.0-15% |
Sample Volume | 4μL |
Shelf life of test kit | 9 months |
Weight | ≤800g |
Dimensions | 192(L)*128(W)*108(H)mm |
Principle
The analyzer works based on the principle of boric acid affinity fluorescence quenching. The content of HbA1c is quantitatively detected by detecting the amount of fluorescent substance changing with the binding and quenching of HbA1c and fluorescent substance.
The Application of Boronate affinity in Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test.
After the magnetic beads are pushed into the kit, the borate in the reagent binds to the fluorophore in the magnetic beads, resulting in a large amount of excited fluorescence
After the magnetic beads are pushed into the kit, the borate binds to the fluorophore, producing a large amount of excited fluorescence.
After the sample is added to the reagent, the borate-fluorophore competes with hemoglobin for binding, resulting in a decrease in fluorescence. Because the binding force of unglycated hemoglobin is much greater than that of glycated hemoglobin, the unglycated hemoglobin first binds to the borate-fluorophore, resulting in a sharp drop in fluorescence. The content of unglycated components can be detected during this process.
Next, the glycosylated hemoglobin is bound to a borate-fluorophore. This binding process is slow and therefore the fluorescence quenching process is slow and curvilinear. The fluorescence quenching process in the detection cycle of the instrument can reflect the content of glycosylated hemoglobin.
Feature
• Boronate affinity Method: The HbA1c assay has no interference from common Hb variants
• Ease of use: One-step operation the instrument is ready for use.
• Less than 3-minute test time
• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.
• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.
• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).
Performance Parameters
Certificate
Company Details
Business Type:
Manufacturer
Year Established:
2001
Total Annual:
10000000-50000000
Employee Number:
100~600
Ecer Certification:
Active Member
Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent... Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent...
Get in touch with us
Leave a Message, we will call you back quickly!