China factories

China factory - Shenzhen KHJ Semiconductor Lighting Co., Ltd

Shenzhen KHJ Semiconductor Lighting Co., Ltd

  • China,Shenzhen
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Tank Series ATEX & IECEx Certified LED Explosion Proof Flood Light Hazardous
China Tank Series ATEX & IECEx Certified LED Explosion Proof Flood Light Hazardous

  1. China Tank Series ATEX & IECEx Certified LED Explosion Proof Flood Light Hazardous
  2. China Tank Series ATEX & IECEx Certified LED Explosion Proof Flood Light Hazardous
  3. China Tank Series ATEX & IECEx Certified LED Explosion Proof Flood Light Hazardous
  4. China Tank Series ATEX & IECEx Certified LED Explosion Proof Flood Light Hazardous
  5. China Tank Series ATEX & IECEx Certified LED Explosion Proof Flood Light Hazardous

Tank Series ATEX & IECEx Certified LED Explosion Proof Flood Light Hazardous

  1. MOQ: 1 pcs
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 400pcs/day
Delivery Time 5-10 work days
Packaging Details 720*480*180mm
Product Name Tank Series LED Explosion Proof Flood Light
Operating Voltage 100-277 VAC,347-480 VAC,141-391VDC,491-679 VDC
Power 320W,400W,480W
Available cable outer diameter φ7-φ20(mm)
Cable Entries 2XM20*1.5 (NPT 3/4”, M25*1.5 are optional)
IP Code IP 66
Enclosure Material Aluminium
Protective 27kgCover: Tempered glass,Stand 7J impact
Brand Name KHJ
Model Number Ex-KTK320,Ex-KTK400,Ex-KTK480
Certification ATEX,IECEx,RoHS,CE
Place of Origin Guangdong, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 400pcs/day
Delivery Time 5-10 work days Packaging Details 720*480*180mm
Product Name Tank Series LED Explosion Proof Flood Light Operating Voltage 100-277 VAC,347-480 VAC,141-391VDC,491-679 VDC
Power 320W,400W,480W Available cable outer diameter φ7-φ20(mm)
Cable Entries 2XM20*1.5 (NPT 3/4”, M25*1.5 are optional) IP Code IP 66
Enclosure Material Aluminium Protective 27kgCover: Tempered glass,Stand 7J impact
Brand Name KHJ Model Number Ex-KTK320,Ex-KTK400,Ex-KTK480
Certification ATEX,IECEx,RoHS,CE Place of Origin Guangdong, China

Tank Series Four Luminaires Assembly  ATEX & IECEx Certified LED Explosion Proof Flood Light Hazardous Area

 

This user manual covers the range of ATEX and IECEx Tank Series LED normal/emergency luminaire. These luminaires are constructed with corrosion resistant epoxy coated aluminum alloy body and high impact resistance tempered glass diffuser.

 

Tank Series Four Luminaires Assembly  LED are available from 320W to 480W, providing ideal solutions for a wide range of harsh and hazardous applications.


Features And Benefits:

1. High efficacy LED Source with long lifespan>100,000 hours.
2. 5-year performance warranty.
3. Low THD around 10%,Less interference.
4. 6KV Surge Protection.
5. Robust aluminium housing and strong tempered glass.
6. Vibration and shock resistant.
7. Low maintenance.
8. Dust proof structure design to avoid dust accumulation.

 

Product Important Information​:

Type Of Protection Ex db ,Ex tb
Protection Standards

(IEC)EN 60079-0, (IEC)EN 60079-1, (IEC)EN 60079-28, (IEC)EN 60079-31

EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3,

EN 60598-1, EN 60598-2-5, EN 62031, EN 62493,

IEC 62321-4, IEC 62321-5, IEC 62321-6, IEC 62321-7-1, IEC 62321-7-2, IEC 62321-8

Area Classfiction

Zone 1 and Zone 2 Areas to (IEC)EN 60079-10-1,

Zone 21 and Zone 22 Areas to (IEC)EN 60079-10-2

Installation (IEC)EN 60079-14
Certificate  
Equipment Coding

II 2 G Ex db IIC T* Gb

II 2 D Ex tb IIIC T* Db IP66

Temperature Class Rated power (W) -40℃ ≤ Ta ≤ +55℃
Gas Dust
80W~480W T5 T95℃
ATEx Coding Tank Series ATEX & IECEx Certified LED Explosion Proof Flood Light Hazardous Area 0II 2 G / II 2 D
Ingress Protection IP66 (IEC)EN 60529
Cable entry M20*1.5,M25*1.5,3/4 NPT
CE Mark

The CE marking of this product applies to EU directives 2014/35/EU, 2014/30/EU, 2012/19/EU , 2011/65/EU and 2014/34/EU respectively.

The Equipment is declared to meet the provisions of the ATEX directive(2014/34/EU)by reason of the EC

Type Examination and compliance with the Essential Health and Safety Requirements

 

Electrical Supplies:

size:640*348*145mm
Voltage Range(AC) 100-277VAC (standard)
Frequency Range(Hz) 50/60Hz
Power Watts(W) 240W 300W 360W
Standard Current Range(A) 0.86~2.4 1.08~3.0 1.3~3.6

 

Applications:
1. Oil&Gas Exploration
2. Drilling
3. Oil Refinery
4. Petrochemical Plant
5. Power Plant
6. Pharmaceutical Plant


Ordering Information:

P/N

Operating Voltage(V)

Luminous Flux(lm)

Power(W)

CRI

Color Temp.

CCT(K)

Temp.

Classification

Ex-KTK320**CH-S4-E

 

 

 

 

100-277 VAC

(141-392 VDC)

46400

 

 

320

70 Cool white 5700±300k T5
Ex-KTK320**NH-S4-E 46400 70 Natural white 5000±300k T5
Ex-KTK320**NH-S4-E 46400 70 Natural white 4000±300k T5
Ex-KTK320 **WM-S4-E 41760 70 Warm white 3000±300k T5
Ex-KTK400**CH-S4-E 58054

 

 

400

70 Cool white 5700±300k T5
Ex-KTK400**NH-S4-E 58054 70 Natural white 5000±300k T5
Ex-KTK400**NH-S4-E 58054 70 Natural white 4000±300k T5
Ex-KTK400**WM-S4-E 52248 70 Warm white 3000±300k T5
Ex-KTK480**CH-S4-E 69120

 

 

480

70 Cool white 5700±300k T5
Ex-KTK480**NH-S4-E 69120 70 Natural white 5000±300k T5
Ex-KTK480**NH-S4-E 69120 70 Natural white 4000±300k T5
Ex-KTK480**WM-S4-E 62208 70 Warm white 3000±300k T5

 

Remarks:

1.The first * stands for Operating Voltage including default-100 - 277 VAC , D-347-480VAC ,E-20-30VAC.
2.The second * stands for Candela Distribution including H3V3,H5V5,H6V6.
 

Cleaning of luminaire:

The complete luminaire (without disassemble) can be cleaned with neutral water solution. After cleaning, rinse or wipe dry with clean water.

It is forbidden to use any chemical or hydrocarbon solvent cleaner to clean the diffuser, otherwise serious damage may be caused.

Please clean the luminaire once a year if it is used under dust environment.

 

Disposal of Material:

Disposal of the luminaire as waste should be carried out in accordance with national regulations. Any disposal must satisfy the requirements of the WEEE directive [2012/19/EU] and therefore must not be treated as commercial waste. The unit is mainly made from incombustible materials. The control gear contains plastic, resin and electronic components. All electrical components may give off noxious fumes if incinerated.

 

Transportation:

Weatherproof measures should be taken during transportation.

It is strictly forbidden to load and unload violently, and it is strictly forbidden to drop and roll from high altitude, so as to prevent mechanical damage.

 

Storage:

The luminaire should be stored in ventilated, non-dropping and non-liquid warehouse at the temperature of -20℃ to +40℃ and relative humidity ≤95%RH.

The surroundings should be kept from corrosive gases which may damage metal and insulation.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2009

  • Total Annual:

    50000000-100000000

  • Employee Number:

    400~500

  • Ecer Certification:

    Active Member

Focus on security and energy-saving, Carry brightness and Sustainable future.     About Us KHJ’s management concept is “people oriented”, and it emphasizes “more pay for more work”. KHJ has perfect salary system which stands in a leading level ... Focus on security and energy-saving, Carry brightness and Sustainable future.     About Us KHJ’s management concept is “people oriented”, and it emphasizes “more pay for more work”. KHJ has perfect salary system which stands in a leading level ...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen KHJ Semiconductor Lighting Co., Ltd
  • KHJ industrial park,Building1,Chuangxin industrial park,Xintian community,Guanlan,Longhua new district,Shenzhen,China.
  • https://ledexplosionprooflights.ecer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement