Supply Ability | 100 Piece/Pieces per Week |
Packaging Details | Wooden box. |
Certificate | ISO9001:2000 |
Aftersell service | 12 months |
Material | 316L |
measuring range | 50Pa~10MPa |
Signal output | 4~20mA |
transmission distance | above 1000m |
working voltage | 12~45V DC |
weight | about 3.5KG |
application | oil, pollution water, diesel fuel, chemical industry |
Name | Magnetic flow meter |
Port | Shanghai/Shenzhen |
Brand Name | Vacorda |
Model Number | HKLD |
Certification | CE/ISO9001 |
Place of Origin | Sichuan, China (Mainland) |
View Detail Information
Explore similar products
Usa Standard Atex Water Sewage Electromagnetic Flow Meter For Liquid Propane
4-20mA output water turbine flow meter for liquid measurement
Good quality water turbine flow meter measuring instrument
ISO9001 Manufacture High Pressure RF Remote Magnetic Sewage Electromagnetic Flow
Product Specification
Supply Ability | 100 Piece/Pieces per Week | Packaging Details | Wooden box. |
Certificate | ISO9001:2000 | Aftersell service | 12 months |
Material | 316L | measuring range | 50Pa~10MPa |
Signal output | 4~20mA | transmission distance | above 1000m |
working voltage | 12~45V DC | weight | about 3.5KG |
application | oil, pollution water, diesel fuel, chemical industry | Name | Magnetic flow meter |
Port | Shanghai/Shenzhen | Brand Name | Vacorda |
Model Number | HKLD | Certification | CE/ISO9001 |
Place of Origin | Sichuan, China (Mainland) | ||
High Light | 10MPa Electromagnetic Flow Meter ,50Pa Electromagnetic Flow Meter ,50Pa electromagnetic water meter |
Flow Rate LCD Display Fischer Porter Electromagnetic Flow Meter
Application:
Due to its unique advantages, it is widely used in the fields of petroleum, chemical industry, steel, light industry, sewage processing, environmental protection, water conservancy project and pharmacy to measure the volume flow of the conducted liquid mediums, such as acid, alkali, salt solution and so on.
Features:
1. High Definition LCD display with backlight.
2. Full-digital processing, high noise resistance and reliable measurement
3. 16 bits embedded microprocessor
4. High precision 0.5%F.S measurement is not affected by fluid density, viscosity, temperature, pressure the influence for the conductivity changes.
5. After power outage, daily total, monthly total data recording function,To calculate the leakage flow automatically ,Circular recording 2050 dates,Free on-site maintenance
6. Double layer protection technique:360 ° spray paint, Polishing technology wear-resisting, anti-rust durable
7. Header board:Using a synthetic version, the integration is high, antioxidant, long life
8. 3 electrode: Ground electrode structure, eliminate the influence of electrical noise, provide measurement precision effectively
Technical parameters:
PTFE Lined Pipe | 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 |
Rubber Lined Pipe | 40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400, 500, 600, 800, 1000, 1200, note: special specifications can be customized |
Flow direction | positive and negative, net flows Turndown |
Measuring range ratio | 150:1 |
Repeatability error | +/-0.1% |
Accuracy | piped: 0.5 class, 1.0 class |
Measured medium temperature | Common rubber lining: -20~+60 ° c |
High temperature rubber lining: -20~+90 ° c | |
PTFE lining: -30~+100 ° c | |
High temperature vinyl lining: -30~+180 ° c | |
Rated working pressure | pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa; DN200~DN1200: ≤ 1.0MPa |
Flow measuring range | flow measuring range corresponding to flow rate range is 0.3~15m/s |
Measured fluid conductivity | 5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow) |
Output | Current:4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA |
Load resistance | < 600 Ω |
Electrode material | 316L, titanium (Ti), tantalum (Ta), Hastelloy, (h), Platinum (Pt) or other special electrode materials |
Protection grade | standard: IP65; IP68 |
Working power supply | 85~265VAC 45~63HZ |
Straight pipe length | pipe: ≥ 5DN in the upper reaches, downstream of greater than or equal to 2DN |
Connections | flow meter connected to the piping is used between flanges, flange connection dimensions comply with GB9119-88 requirements. |
Explosion-proof mark | mdllBT4 |
environment temperature | -25 ° c ~=60 ° c |
Relative humidity | 5%~95% |
Total power consumption | <20W |
Q:What are the products VACORDA offer ?
A: Pressure sensor, level sensor, flow meter and digital controllers.
Q:Could I get samples?
A:Yes,we have materials in stock to help you to get the samples as soon as we can.
Q:How about the quality of the magnets?
A:We have the certification of ISO, TUV-CE and ROSH,we could send the certification test of our company to you.
Q:Could you provide me the shortest lead time?
A:We have materials in our stock,if you really need,you can tell us and we will try our best to satisfy you.
Q:Could I visit your factory?
A:Of course,if you need we will help you to visit our factory.
Q: How can I get the quotation or send my inquiry to?
A: Send your inquiry to us by the inquiry from on the right-side or the bottom of this page.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1997
Total Annual:
100W-150W
Employee Number:
>150
Ecer Certification:
Active Member
Sichuan VACORDA Instruments Manufacturing Co., Ltd.is a professional production-manufacturing enterprise specialized in designing, producing and marketing of instruments and apparatuses. Our company has been established for 23 years since 1997 to grow up to be a team of high-quality, united, hard-wo... Sichuan VACORDA Instruments Manufacturing Co., Ltd.is a professional production-manufacturing enterprise specialized in designing, producing and marketing of instruments and apparatuses. Our company has been established for 23 years since 1997 to grow up to be a team of high-quality, united, hard-wo...
Get in touch with us
Leave a Message, we will call you back quickly!