Packaging Details | WOODEN CASE |
Delivery Time | 35~45days |
Payment Terms | TT,LC |
Supply Ability | 3000 sets/Years |
Place of Origin | ZHEJIANG,CHINA |
Brand Name | SHENGDI TECHNOLOGY |
Certification | GS,CNAS |
Model Number | HS6103F |
View Detail Information
Explore similar products
1 PHA Sequential Connection IEC Class Meter Test Equipment (HS-6103)
Front Load Single Phase Smart Meter Test Bench HS-6103F
Energy Meter Testing And Calibration HS-6103F Double Loop Single Phase Static
Single Phase Prepaid Smart Meter Testing and Calibration HS-6103F
Product Specification
Packaging Details | WOODEN CASE | Delivery Time | 35~45days |
Payment Terms | TT,LC | Supply Ability | 3000 sets/Years |
Place of Origin | ZHEJIANG,CHINA | Brand Name | SHENGDI TECHNOLOGY |
Certification | GS,CNAS | Model Number | HS6103F |
HS-6103F SINGLE PHASE ENERGY METER TEST BENCH
AUTOMATIC CHANGE TO CALIBRATE/TEST LINE AND NEUTRAL
(40 POSITIONS)
This specification for single phase dual loop(Double circuit) energy meter test bench.
Features
1) The bench accords with the standard of “ IEC 60736:1982 testing equipment for electrical energy meters”, “IEC 62053”
2) The bench can be used to test single phase energy meter (up to 0.5 class), include 1P2W & 1P3W energy meter. It can be select current circuit (phase circuit or neutral circuit) via select switch. It can be closed with the current circuit & the voltage circuit.
3) The bench can do warm up testing, starting testing, no load testing (creep testing), error testing(accuracy testing), dial testing, testing of the influence quantities (voltage, frequency, neutral cut off, etc. ) and testing of repeatability of the measurements etc.
4) The bench is using the PWM technology to amplify voltage/current output, the high efficiency at >85%, and lower the heat. The PWM can check the malfunction checking, preset, alarm, and protection.
5) The signal source is using the newest digital controlled sine wave technology for frequency, amplitude and phase adjust.
6) The bench is using comparison technology to test the error of energy meters.
7) The bench is using the error processor system to calculate the error of each energy meter by the sub-error system which can be connected by the internal RS485.
8) Different constant energy meter can be tested at one time.
9) Voltage is isolated by MSVT(multi secondary voltage transformer)output, which suits for the voltage/current close-link test of signal phase energy meter
10) The test bench can be installed scanning head, it can offer 3 ranges adjustment. It is also can be accepted the signal for both round-style energy meter and digital LED energy meter.
11) The test bench has the auto-search black marker function which can precisely locate the black marker during the no load test and starting test.
12) The bench can choose to operate by keyboard or PC which is very convenient. The working status of bench can be seen very clear and easy operation.
13) The bench is using the testing software complied with WINDOWS98/2000/XP which can auto-testing different energy meters.
14) The software can realize the data from energy meter for statistics, search and management.
15) The energy meter mounting rack is made by Aluminum compound. The whole device configuration is a reasonable design and nice outfit.
Technical Specification
1) The test bench accuracy class: 0.05/0.1class
2) Reference standard energy meter:
HS-5100 single phase reference standard energy meter
Accuracy class: 0.05 /0.1
3) MSVT(multi secondary voltage transformer) class: 0.01
Secondary voltage: 100-300V
Secondary VA rating:15VA per winding
Insulation secondary to secondary: 500V, 50Hz, 60 seconds
Secondary to secondary ratio accuracy less than : ±0.01%
Secondary to secondary phase angle accuracy less than ±1 minute
Number of secondary output: 6~48channel
4) Voltage amplifier:
Output voltage range: 0-275/300V;
Output maximum power: 800VA
Resolution: 0.01%;
Stability: better than 0.05%/3 min (time base 5S);
Distortion factor: < 0.5% at linear load;
Frequency range: 45Hz~65Hz;
Power efficiency: more than 85%;
Ambient temperature:10℃~50℃
Electronic overload and short-circuit protection.
5) Current amplifier:
Output current: range: 1mA~120A;
Output maximum power: 2000VA
Resolution: 0.01%;
Stability: better than 0.05%/3 min (time base 5S);
Distortion factor: < 0.5% at linear load;
Frequency range: 45Hz~65Hz;
Power efficiency: greater than 85%;
Ambient temperature:10℃~50℃
Electronic overload protection and security for open current circuit.
6) Phase Angle: 0°~360° , resolution of phase angle setting: 0.1°;
7) Output frequency range: 45Hz~65Hz; resolution: 0.01Hz
8) Output stability of power: <0.05% (180S)
9) Numbers of calibrated energy meter: 24 (6/12/24/32/40/48 on requested)
10) Input power: 220/240V 15%, 50/60Hz; power consumption: Max.2500VA
11) Dimension:
Type of bench | Meters | Number of rack | Number of row | Size of rack |
Integration | 6 12 24 32 40 48 | 1 1 1 2 2 2 | Single Double Double Double Double Double | 1600×800×1600 mm 1600×800×1920 mm 2400×800×1920 mm 1800×800×1920 mm 2000×800×1920 mm 2400×800×1920 mm |
Fission | 24 32 40 48 | 1 2 2 2 | Double Double Double Double | 2400×700×1920 mm 1800×700×1920 mm 2000×700×1920 mm 2400×700×1920 mm |
Size of Console: 600×800×1920 mm |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2007
Total Annual:
5,000,000-10,000,100
Employee Number:
200~500
Ecer Certification:
Active Member
We are the manufacturer of HS Series Single & Three-Phase Energy meter Test Bench. HS-6103 Single-Phase energy meter test device(bench) Multi-function,Double Loop. HS-6303 Three-Phase energy meter test bench ... We are the manufacturer of HS Series Single & Three-Phase Energy meter Test Bench. HS-6103 Single-Phase energy meter test device(bench) Multi-function,Double Loop. HS-6303 Three-Phase energy meter test bench ...
Get in touch with us
Leave a Message, we will call you back quickly!