Payment Terms | L/C, T/T |
Supply Ability | 20 million meters per year |
Delivery Time | in one month |
Packaging Details | plywood crates |
Sheath | Stainless Steel |
Function | Metal Alloy Melting |
Application | Metal Industry |
Diameter | 2 mm |
Cable Length | in Meter |
Power | in Watt |
Vottage | Volt |
Unit Weight | Up to 184 kg/km |
Brand Name | MICH |
Model Number | MIHC |
Certification | ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
Inconel 600 Heat Tracing Cable 600V Double Cores
Three Cores Mineral Insulated Heating Cable For Electric Heater
825 Mineral Insulated Heat Trace Cable Anti Corrosion
Cupronnickel 5.3mm Mineral Insulated Heating Cable Heat Tracing
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 20 million meters per year |
Delivery Time | in one month | Packaging Details | plywood crates |
Sheath | Stainless Steel | Function | Metal Alloy Melting |
Application | Metal Industry | Diameter | 2 mm |
Cable Length | in Meter | Power | in Watt |
Vottage | Volt | Unit Weight | Up to 184 kg/km |
Brand Name | MICH | Model Number | MIHC |
Certification | ISO9001 | Place of Origin | China |
High Light | SS Mineral Insulated Wire ,2mm Mineral Insulated Wire ,2mm heating element cable |
Low Melting Point Alloy Melting Use MI Heating Cable for Metal Manufacturing Industry can meet the requirements of high temperature condition and high heating power (up to 269W/m).The maximum heating temperature can reach up to 600℃. Conductor resistance value ranges from 2.1 to 36100Ω/km supplied by MICH. Mineral insulated heating cable possesses excellent mechanical strength and corrosion resistance. The heating cable of series resistance can meet the requirements of different power.
Application
Nuclear industry | construction -- asphalt heating |
Metal manufacturing industry- low melting point alloy melting | tank/vessel heating |
Shell heating for the extruder | Heat tracing for high temperature industrial piping |
anticoagulation and viscosity reduction of process media | All kinds of industrial electric heaters |
Cable Structure
Specification
Heating cable instruction code
MI SS-B 16K6560/60/2520/220/E1
NO. 1 2 3 4 5 6 7
No. | Instruction | |
1 | Sheath material | Stainless steel |
2 | structure of cable components | shown in table 1 |
3 | cable codes | shown in table 2, 3 and 4 |
4 | length of heating cable | In meter |
5 | Heating cable power | In Watt |
6 | heating cable voltage | In Volt |
7 | heating cable voltage | See table 5 |
Cable Code
Serial NO. | Instruction | |
1 | core number | 1 or 2 |
2 | Voltage grade | 3=300V, 6=600V |
3 | conductor materials | K,N,C |
4 | cold resistance ×1000 | 6560=6.56Ω/m×1000 |
1 6 K 6560
No 1 2 3 4
Table 1 Structure of Cable Element
Table 2 Heating Cable Specification (600V Single Core)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
16C2.1 | 6.8 | 0.0021 | 130 | 184.2 |
16C3.4 | 5.9 | 0.0034 | 173 | 138.7 |
16C5.3 | 5.3 | 0.0053 | 214 | 111.9 |
16C8.5 | 4.8 | 0.0085 | 261 | 91.8 |
16C13 | 4.3 | 0.013 | 325 | 73.7 |
16C21 | 4.0 | 0.021 | 376 | 63.8 |
16K40 | 5.8 | 0.04 | 179 | 164.7 |
16K50 | 5.4 | 0.05 | 206 | 140.1 |
16K60 | 5.2 | 0.06 | 222 | 126.7 |
16K80 | 4.8 | 0.08 | 261 | 106.8 |
16K100 | 4.7 | 0.1 | 200 | 100.0 |
16K120 | 4.5 | 0.12 | 200 | 90.2 |
16K160 | 6.5 | 0.16 | 200 | 77.7 |
16K200 | 5.9 | 0.2 | 200 | 110.0 |
16K250 | 5.3 | 0.25 | 215 | 92.1 |
16K400 | 4.7 | 0.4 | 280 | 74.0 |
16K500 | 4.5 | 0.5 | 300 | 66.2 |
16N630 | 4.3 | 0.63 | 185 | 94.1 |
16N1000 | 3.9 | 1.0 | 230 | 91.3 |
16N1600 | 3.6 | 1.6 | 270 | 88.2 |
16N2500 | 3.4 | 2.5 | 300 | 69.8 |
16N2800 | 3.4 | 2.8 | 300 | 76.0 |
16N3300 | 3.4 | 3.3 | 300 | 68.9 |
16N4000 | 3.2 | 4.0 | 350 | 68.5 |
16N5200 | 3.2 | 5.2 | 350 | 68.2 |
16N6300 | 3.2 | 6.3 | 350 | 55.5 |
16N10000 | 3.2 | 10 | 350 | 41.7 |
Table 3 Heating Cable Specification (600V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
26K8.4 | 11.8 | 0.0084 | 43 | 636.1 |
26K13.4 | 9.8 | 0.0134 | 63 | 433.7 |
26K21 | 8.8 | 0.021 | 78 | 340.7 |
26K34 | 8.0 | 0.034 | 94 | 275.2 |
26K54 | 7.1 | 0.054 | 119 | 213.6 |
26K85 | 6.4 | 0.085 | 147 | 171.2 |
26K130 | 6.0 | 0.13 | 167 | 148.6 |
26K180 | 7.9 | 0.18 | 96 | 273.3 |
26K260 | 7.4 | 0.26 | 110 | 235.4 |
26K360 | 6.8 | 0.36 | 130 | 196.6 |
26K500 | 6.4 | 0.5 | 100 | 172.1 |
26K650 | 5.9 | 0.65 | 100 | 145.6 |
26K1000 | 5.7 | 1.0 | 100 | 134.1 |
26K1300 | 6.2 | 1.3 | 100 | 161.5 |
26K2000 | 5.8 | 2.0 | 100 | 139.8 |
26K3300 | 5.4 | 3.3 | 100 | 119.5 |
26N4600 | 5.8 | 4.6 | 100 | 139.0 |
26N8000 | 5.4 | 8.0 | 100 | 119.2 |
26N13000 | 5.0 | 13.0 | 100 | 101.3 |
26N27000 | 4.8 | 27.0 | 100 | 92.6 |
26N40000 | 4.6 | 40.0 | 100 | 84.9 |
26N60000 | 4.4 | 60.0 | 100 | 77.5 |
26N72000 | 4.2 | 72.0 | 100 | 70.6 |
Table 4 Heating Cable Specification (300V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight | ||
mm | Ω/m | m | kg/km | |||
23K210 | 5.2 | 0.21 | 222 | 118.5 | ||
23K300 | 4.8 | 0.3 | 261 | 99.4 | ||
23K400 | 4.8 | 0.4 | 261 | 97.7 | ||
23K480 | 4.8 | 0.48 | 261 | 96.5 | ||
23K650 | 4.6 | 0.65 | 284 | 87.8 | ||
23K1000 | 4.1 | 1.0 | 100 | 69.3 | ||
23K1300 | 3.8 | 1.3 | 100 | 59.3 | ||
23K2000 | 5.0 | 2.0 | 100 | 105.3 | ||
23K2400 | 4.8 | 2.4 | 100 | 96.2 | ||
23K3000 | 4.6 | 3.0 | 100 | 87.8 | ||
23N4600 | 4.8 | 4.6 | 100 | 96.8 | ||
23N7500 | 4.6 | 7.5 | 100 | 87.4 | ||
23N11200 | 4.4 | 11.2 | 100 | 79.2 | ||
23N14000 | 4.2 | 14.0 | 100 | 72.0 | ||
23N18000 | 3.6 | 18.0 | 100 | 52.9 | ||
23N26000 | 3.6 | 26.0 | 100 | 52.5 | ||
23N40000 | 3.4 | 40.0 | 100 | 46.6 | ||
23N50000 | 4.0 | 50.0 | 100 | 64.2 | ||
23N60000 | 3.6 | 60.0 | 100 | 52.0 | ||
23N72000 | 3.4 | 72.0 | 100 | 46.4 |
Note:
The resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);
If not specified, the sheath material is based on SS 321;
For the use of 660V voltage occasions, please contact our company professionals.
Table 5 terminal specifications
Model: A, D, E | Model: B | |||
Maximum Voltage (V) | Maximum Current (A) | Terminal Specification | Maximum Current (A) | Terminal Specification |
600 | 15 | E2 | 20 | E1 |
600 | 20 | E2 | 25 | E2 |
600 | 30 | E3 | 40 | E2 |
600 | 50 | E3 | 70 | E2 |
600 | 70 | E3 | 100 | E3 |
Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.
Note 2: the length of cold end cable with standard configuration is 2 meters. If increase or decrease of length required, please contact our professional personnel.
Corresponding reference table between the output power and sheath temperature
Anticorrosive specification
Material | Application |
Sulfate | Not Recommend |
Hydrochloric acid | Not Recommend |
Hydrofluoric acid | Not Recommend |
Phosphate | Not Recommend |
Carbonate | According to the real Data |
Organic acid | Applicable at any condition |
Alkali metal | Acceptable |
Sea water | Not Recommend |
Chloride | Not Recommend |
Explosion-proof instructions
MISS series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to Ⅱ A, Ⅱ B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.
Company Details
Business Type:
Manufacturer
Year Established:
2008
Employee Number:
150~200
Ecer Certification:
Active Member
Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering... Pasia Industries is a scientific and technological enterprise specializing in researching, developing, producing, installing and providing technical consultation and service for mineral insulated heating cables, heating elements and finished heaters as well as welded honeycomb products for filtering...
Get in touch with us