Payment Terms | L/C, T/T, Western Union |
Supply Ability | 1000 Unit per month |
Delivery Time | 15 working days |
Packaging Details | Standard export packaging |
Runing Voltage | regular 12KV |
Runing Current | max 2000A |
Breaking current | 20-25KA |
Type | Fixed |
Standard | GB,IEC,ISO |
Manufactory | KNKONG-ELECTRIC |
Brand Name | KNKONG |
Model Number | VS1-12 |
Certification | CB,ISO,IEC |
Place of Origin | China |
View Detail Information
Explore similar products
20KA Alternating Withdrawable VCB Circuit Breaker 12KV
Embedded Pole VCB Circuit Breaker 2000A 12KV For Transformer Substation
2000A 12KV Withdrawable Circuit Breaker Modularized Mechanism
Fixed Type 205 Phase Spacing VCB Circuit Breaker Environmental Protection
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 1000 Unit per month |
Delivery Time | 15 working days | Packaging Details | Standard export packaging |
Runing Voltage | regular 12KV | Runing Current | max 2000A |
Breaking current | 20-25KA | Type | Fixed |
Standard | GB,IEC,ISO | Manufactory | KNKONG-ELECTRIC |
Brand Name | KNKONG | Model Number | VS1-12 |
Certification | CB,ISO,IEC | Place of Origin | China |
High Light | 20KA Breaking Switchgear Circuit Breaker ,Indoor Switchgear Circuit Breaker ,Fixed Type Switchgear Circuit Breaker |
20KA Breaking indoor type switchgear using vacuum circuit breaker fixed type VS1 series
Voltage: regular 12KV
Current: max 2000A
Breaking current: 20KA
Type: Fixed
Phase spacing: 205
Product overview
VS1 vacuum circuit breaker is used in 12kV, 24KV three-phase AC 50/60Hz indoor switchgear, and can be used for the protection and control of industrial and mining enterprises and substation equipment. The spring operating mechanism of VS1 series circuit breaker is a modular independent frame design, installed in KYN28-12 (24) centralized and fixed switch cabinets. The VS1 circuit breaker can be fixedly installed or used in combination with a trolley.
VS1-Series circuit breakers are Class M2.c2 and E2 model
VS1 series circuit breakers are maintenance-free and can be operated frequently. Compared with traditional circuit breaker products, the mechanical durability of VS1 circuit breaker has been improved from 10,000 ops to 20,000 ops, which is a huge improvement. The type test of capacitive current interruption shows a very low probability of re-arcing. VS1 has a long electrical life and free maintenance.
Technical Parameters
No. | Item | Unit | Parameter | ||||||
1 | Rated voltage | KV | 12 | ||||||
2 | Rated frequency | Hz | 50/60 | ||||||
3 |
Rated insulation level | 1min power frequency withstand voltage(r. m. s) |
KV | 42(phase-to-phase, phase-to-earth) 48(across the isolating distance) | |||||
Lighting impulse withstand voltage (peak) | 75(phase-to-phase, phase-to-earth) 85(across the isolating distance) | ||||||||
4 |
Rated current |
A | 630 | 630 | 1250 | 1600 | |||
1250 | 1250 | 1600 | 2000 | ||||||
2000 | 2500 | ||||||||
2500 | 3150 | ||||||||
4000 | |||||||||
5 | Rated short-circuit breaking current |
KA | 20 | 25 | 31.5 | 40 | |||
6 | Rated short-time withstand current | 20 | 25 | 31.5 | 40 | ||||
7 | Rated short-circuit marking current | 50 | 63 | 80 | 100 | ||||
8 | Rated peak withstand current | 50 | 63 | 80 | 100 | ||||
9 | Rated duration of short-circuit | s | 4 | ||||||
10 | Rated operating sequence | O-0.3s-O/C-180s-O/C | |||||||
11 | Breaking times of rated short-circuit current | Times | 30/20 times(40KA) | ||||||
12 | Mechanical endurance | Ops | 20000 | ||||||
13 | Rated single capacitor bank breaking current |
A | 630 | ||||||
14 | Rated back-to-back capacitor bank breaking current | 400 | |||||||
15 | Double-earth fault breaking current | 27.4 | |||||||
16 | Allowable maximum contact erosion |
mm | 3 | ||||||
17 | Clearance between open contacts | 10±1 | |||||||
18 | Over stroke | 3.5±0.5 | |||||||
19 | Non-simultaneity of 3-phase opening and closing | ms
| ≤2 | ||||||
20 | Bounce duration of contact closing | ≤2 | |||||||
21 | Average breaking speed (instant breaking 6mm) | m/s
| 1.1±0.2 | ||||||
22 | Average making speed | 0.8±0.2 | |||||||
23 | Making time | ms
| ≤100 | ||||||
24 | Breaking time | ≤50 | |||||||
25 |
Resistance of each phase main circuit |
μ Ω | 630A | ≤50 | |||||
1250A | ≤45 | ||||||||
1600A~2000A | ≤35 | ||||||||
≥2500A | ≤25 | ||||||||
26 | Contact breaking bounce amplitude | mm | ≤2 | ||||||
27 | Rated operating voltage | Rated operating voltage(V)AC/DC |
V | 24* | 110 | 220 | |||
Scope of normal operation voltage | Opening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed | ||||||||
28 | Rated voltage of energy storage motor | V | AC110/220,DC110/220 | ||||||
29 | Energy storage time | S | ≤15 |
Company Details
Business Type:
Manufacturer
Year Established:
2012
Total Annual:
1000000-9000000
Employee Number:
50~100
Ecer Certification:
Active Member
Knkong Electric Co., Ltd (Zhengzhou Knkong Mechanical And Electrical Co., Ltd)was established in 2012. A wholly-owned subsidiary of Henan Sanhe Electric Group. We are mainly responsible for overseas market exporting, electronic components, and technology import. Relying on a h... Knkong Electric Co., Ltd (Zhengzhou Knkong Mechanical And Electrical Co., Ltd)was established in 2012. A wholly-owned subsidiary of Henan Sanhe Electric Group. We are mainly responsible for overseas market exporting, electronic components, and technology import. Relying on a h...
Get in touch with us
Leave a Message, we will call you back quickly!